1 Introduction
High-order harmonic generation (HHG) from atoms and molecules driven by intense laser pulses has attracted significant attention in the last three decades[Reference Burnett, Baldis, Richardson and Enright1–Reference Li, L’Huillier, Ferray, Lompré and Mainfray3]. As a nonperturbative nonlinear process, HHG not only opens a new route to generate coherent tabletop x-ray sources and attosecond pulses[Reference Gibson, Paul, Wagner, Tobey, Gaudiosi, Backus, Christov, Aquila, Gullikson, Attwood, Murnane and Kapteyn4–Reference Goulielmakis, Schultze, Hofstetter, Yakovlev, Gagnon, Uiberacker, Aquila, Gullikson, Attwood, Kienberger, Krausz and Kleineberg6], but also provides an effective tool for probing the ultrafast dynamics of atoms/molecules on angstrom scale[Reference Drescher, Hentschel, Kienberger, Uiberacker, Yakovlev, Scrinzi, Westerwalbesloh, Kleineberg, Heinzmann and Krausz7–Reference Uiberacker, Uphues, Schultze, Verhoef, Yakovlev, Kling, Rauschenberger, Kabachnik, Schroder, Lezius, Kompa, Muller, Vrakking, Hendel, Kleineberg, Heinzmann, Drescher and Krausz9]. HHG can be well understood in the framework of semiclassical three-step model[Reference Corkum10, Reference Schafer, Yang, DiMauro and Kulander11]: (i) tunnel ionization of the electrons into the continuum state; (ii) generation of recolliding electrons moving towards the parent ion in the oscillating laser field; and (iii) recombination of the returned electrons with the ions that leads to emission of coherent photons with photon energies above the Coulomb potential.
Recently, HHG from excited states of atoms/molecules has been attracting growing interest due to its potential to generate high-order harmonics with enhanced conversion efficiency and/or extended cut-off energy[Reference Wang, Cheng, Li, Fu, Chen and Liu12–Reference Ishikawa14]. Besides, it also provides us an opportunity to investigate extreme nonlinear optical process (i.e., nonperturbative characteristics) of excited states, which is fundamental in photochemistry and photobiology. However, most investigations on HHG from excited states are based on a coherent superposition of ground state and excited states because of the strong laser fields involved, which enable generation of harmonics from both the ground and excited states[Reference Sanpera, Watson, Lewenstein and Burnett15–Reference Wei, Yuan, Liu, Zeng, Zheng, Jiang, Ge and Li17]. Such scheme is beneficial for promoting the conversion efficiency of HHG. On the other hand, around one decade ago, Paul et al. experimentally demonstrated HHG completely from the excited states of alkali-metal atoms (i.e., rubidium), which was realized by cascade excitation in the presence of a weak continuum wave laser field[Reference Paul, Clatterbuck, Lyngå, Colosimo, DiMauro, Agostini and Kulander18]. It should be noted that HHG from pure excited states of noble gases has not been reported, as a similar near-resonant optical excitation requires strong sources of extreme UV light[Reference Ishikawa14, Reference Sekikawa, Okamoto, Haraguchi, Yamashita and Nakajima19, Reference Huffman, Larrabee and Chambers20]. Another difficulty is that for atoms and molecules on the excited states, their ionization potentials are too low to maintain a sufficiently low Keldysh parameter (i.e., $\unicode[STIX]{x1D6FE}=\sqrt{I_{p}/(2U_{p})}$ , where $I_{p}$ represents ionization potential and $U_{p}$ represents ponderomotive energy) at the wavelengths near 800 nm[Reference Keldysh21]. This issue can be nicely overcome because of the rapid development of intense mid-infrared femtosecond laser sources whose extended wavelengths can ensure the ionization of the excited atoms/molecules in the tunnel regime[Reference Sheehy, Martin, DiMauro, Agostini, Schafer, Gaarde and Kulander22].
In this work, we experimentally generate the above-threshold harmonics completely from pre-excited argon atoms using a simple all-optical approach. By comparing the characteristics of an above-threshold harmonic and that of a below-threshold harmonic, our results reveal the nonperturbative physical picture of the above-threshold harmonic.
2 Experimental setup
The pump–probe experimental setup is schematically illustrated in Figure 1, which is similar to that used in our previous works[Reference Xie, Li, Yao, Chu, Li, Zeng, wang, Jing, Li and Cheng23–Reference Li, Yao, Zhang, Jing, Zeng, Chu, Ni, Xie, Liu, Chen, Cheng and Xu25]. Briefly, the mid-infrared femtosecond laser pulses were provided by optical parametric amplifier (OPA, HE-TOPAS, Light conversion, Ltd.) pumped by a commercial Ti:sapphire laser system (Legend Elite-Duo, Coherent Inc.). In this experiment, a signal beam at the wavelength of 1420 nm (pulse duration: ${\sim}80~\text{fs}$ , diameter: ${\sim}8~\text{mm}$ at $1/e^{2}$ ) was used as the pump and the idler beam at the wavelength of 1820 nm (pulse duration: ${\sim}120~\text{fs}$ , diameter: ${\sim}3~\text{mm}$ at $1/e^{2}$ ) was served as the probe. The maximum energy of pump pulse was ${\sim}1~\text{mJ}$ . The probe pulse energy can be continuously adjusted from 640 to $2~\unicode[STIX]{x03BC}\text{J}$ using a variable attenuation filter (VAF). The diameter of probe beam was reduced by a factor of 2.5 with the help of a telescope system inserted in the probe beam path. For the probe pulse energy set at $70~\unicode[STIX]{x03BC}\text{J}$ , the peak intensity of probe pulse at the focus was estimated to be ${\sim}3.5\times 10^{12}~\text{W}/\text{cm}^{2}$ assuming a linear propagation of the laser beam, while the peak intensity of pump pulse was estimated to be ${\sim}5.5\times 10^{15}~\text{W}/\text{cm}^{2}$ . In this case, the pump energy was high enough to generate a 13-mm-long filament, whereas the probe laser alone cannot form any visible plasma owing to its low pulse energy. The pump pulse was set to be circularly polarized for minimizing the supercontinuum generation in the vicinity of the 3rd and 7th harmonics. Meanwhile, the polarization of the probe pulse can be continuously changed from linear to circular by rotating a quarter-wave plate (QWP2). The time delay between the pump and probe pulses was controlled using a delay line in the pump beam path. After being combined by a dichroic mirror (DM1), the pump and the probe pulses were collinearly focused into a gas chamber filled with argon by a 15-cm focal-length lens. The gas pressure of argon was fixed at 1000 mbar. The generated harmonics after the chamber were recorded using a $1200\text{-}\text{grooves}/\text{mm}$ grating spectrometer (Andor Shamrock 303i) after being focused with a 10-cm focal-length lens onto the entrance slit.
3 Experimental results
As shown in Figures 2(a) and 2(b), strong 3rd and 7th harmonics of the probe pulse can be generated when both the pump and probe pulses were focused into the gas chamber filled with argon gas. Here, the probe pulse energy was fixed at ${\sim}70~\unicode[STIX]{x03BC}\text{J}$ . The time delay between the pump and probe pulses was adjusted to be ${\sim}5~\text{ns}$ , and the probe pulse was chosen to be linearly polarized. In addition, it can be seen that no significant harmonic signal can be observed when either of the two laser beams was blocked. It is worth mentioning that apart from the strong 3rd and 7th harmonics were observed in this experiment, the 5th harmonic of the probe pulse was also observed. Besides, the 3rd harmonic is the lowest observable harmonic, and the 7th harmonic is the highest harmonic which can be measured using our grating spectrometer due to the strong absorption of higher UV harmonics in air. Hence, we just compare the different dependences of 3rd and 7th harmonics on the laser parameters to illuminate the nonperturbative characteristics of above-threshold harmonic from pre-excited atoms.
The reason to choose a time delay of ${\sim}5~\text{ns}$ for achieving the strongest harmonic signal is indicated in Figure 2(c), in which we present the measured 7th harmonic signal intensity as a function of the time delay between the pump and probe pulses. It is clear that 7th harmonic signal starts to appear at ${\sim}2~\text{ns}$ after the pump pulse and reaches its peak intensity around ${\sim}5~\text{ns}$ and then shows a gradual decay with the increasing time delay. As we will show later, the temporal dependence we observe in Figure 2(c) directly reflects the dynamics of excitation of the argon atoms with the intense pump pulses.
Figure 2(d) shows the measured spatial beam profiles of 3rd (red squares) and 7th (black circles) harmonics. It can be seen that both the beam profiles of 3rd and 7th harmonics are nearly Gaussian. We fit the experimental data with Gaussian functions and estimate the divergence angles of 3rd and 7th harmonics, which were 13 and 8 mrad in our experiments, respectively. Besides, the conversion efficiency of 7th harmonics from the excited argon atoms is measured to be ${\sim}10^{-7}$ .
Figure 3(a) shows the measured 3rd (red squares) and 7th harmonic (black circles) signals from the excited-state argon atoms as a function of the probe pulse energy. In this measurement, the diameter of the incident probe beam was first reduced by a factor of 2.5 with a telescope system. The pump pulse energy was fixed at 1 mJ and the probe pulse energy was continuously adjusted using the neutral density filter. It should be noted that the peak intensity of the probe laser pulse is estimated to change linearly from $5.06\times 10^{11}$ to $3.0\times 10^{13}~\text{W}/\text{cm}^{2}$ when the probe pulse energy is adjusted from 10 to $600~\unicode[STIX]{x03BC}\text{J}$ by assuming a linear propagation. It can be seen that the measured 3rd harmonic signal dramatically increases with the increasing probe laser energy, which can be well fitted with $y=ax^{3}$ , i.e., it perfectly follows the $I^{3}$ law[Reference Starczewski, Larsson, Wahlstrom, Tisch, Smith, Muffett and Hutchinson26, Reference Liang, Ammosov and Chin27]. On the other hand, the 7th harmonic signal starts to appear when the probe pulse energy reaches $48~\unicode[STIX]{x03BC}\text{J}$ . The 7th harmonic signal then grows nearly linearly with the increasing probe pulse energy. The same conclusion can be drawn with logarithmic scales as shown in the insert.
For comparison, we also generated the harmonics from the ground state of argon and measured their signal intensities as a function of the driving laser energy, as shown in Figure 3(b). In this measurement, we blocked the pump pulse, thus all the argon atoms remained in the ground state. It is worth mentioning that in this case, to generate the 3rd and 7th harmonics by the probe pulse alone, we removed the telescope system in the probe beam path to enhance the peak intensity in the focus region by almost a factor of 6. Under these experimental conditions, the probe laser intensity is calculated to be from $3.16\times 10^{12}$ to $1.9\times 10^{14}~\text{W}/\text{cm}^{2}$ when we change the power of probe pulse from 10 to $600~\unicode[STIX]{x03BC}\text{J}$ . Both the 3rd and 7th harmonic signals increase with the increasing probe pulse energy. Likewise, we fit the measured data of 3rd (red squares) and 7th (black circles) harmonics from the ground-state argon atoms with the function $I^{q}$ , where $q$ is the corresponding harmonic order, and then found that both the 3rd and 7th harmonic signals show a fairly well agreement with the $I^{q}$ law[Reference Starczewski, Larsson, Wahlstrom, Tisch, Smith, Muffett and Hutchinson26, Reference Liang, Ammosov and Chin27].
The dependences of the 3rd harmonic and 7th harmonic signals from the pre-excited argon atoms on the ellipticity of polarization of the probe laser pulse are presented in Figure 4. The ellipticity is defined as the ratio of the minor axis to the major axis of the ellipse, i.e., $\unicode[STIX]{x1D700}=|E_{x}/E_{y}|$ , where $E_{x}$ and $E_{y}$ represent the laser electric field strengths along the horizontal and vertical directions, respectively. To eliminate the influence of detection system on this measurement, we collected the 3rd and 7th harmonic signals using an integrating sphere and a fibre. As shown in Figure 4, both the 3rd (red squares) and 7th (black circles) harmonic signals reach their maxima when the probe pulse is linearly polarized and gradually decreases when the probe pulse varies from linear polarization to circular polarization. The 7th harmonic signal becomes too weak to be detectable when the ellipticity increased to 0.7, whereas the 3rd harmonic signal only decreases by nearly one order of magnitude at the same ellipticity.
4 Discussions
In the pump–probe experiments, we would like to stress that the probe pulse energy (i.e., $70~\unicode[STIX]{x03BC}\text{J}$ ) is too weak to generate any detectable harmonic signals from the ground state of argon. Moreover, because the time delay between the pump and probe pulses is on the order of a few nanoseconds, the harmonic generation contributed by the plasma effect can be excluded due to the relatively short lifetime of the plasma in the femtosecond laser filament[Reference Papeer, Mitchell, Penano, Ehrlich, Sprangle and Zigler28]. Previously, it has been demonstrated that a large population of excited argon atoms can be prepared via a two-step process involving three-body collisions $\text{Ar}^{+}+2\text{Ar}\rightarrow \text{Ar}_{2}^{+}+\text{Ar}$ and dissociative recombination $\text{Ar}_{2}^{+}+e\rightarrow \text{Ar}^{\ast }(4\,^{3}P_{2})+\text{Ar}$ , which is demonstrated on a nanosecond timescale[Reference Kartashov, Ališauskas, Andriukaitis, Pugžlys, Shneider, Zheltikov, Chin and Baltuška29, Reference Xie, Li, Chu, Zeng, Yao, Jing, Li and Cheng30]. Therefore, it is reasonable to attribute the strong 3rd and 7th harmonic signals generated in our experimental conditions to the nonlinear interaction of the probe beam with the excited-state argon atoms prepared by the intense pump laser pulses. Besides, the temporal evolution of 7th harmonic signal in Figure 2(c) agrees well with our previous observations, providing quantitative evidence on the role of the excited state of argon, i.e., $\text{Ar}^{\ast }(4\,^{3}P_{2})$ [Reference Xie, Li, Chu, Zeng, Yao, Jing, Li and Cheng30]. It is noticed that the photon energy of the 3rd harmonic signal is ${\sim}2~\text{eV}$ , whereas the photon energy of 7th harmonic is ${\sim}4.8~\text{eV}$ . The latter is higher than the ionization energy ( ${\sim}4.15~\text{eV}$ ) of argon on the excited state [ $\text{Ar}^{\ast }(4\,^{3}P_{2})$ ]. In general, the above-threshold harmonic is a signature of the nonperturbative nonlinear process, which is further supported by the experimental results in Figure 3. Although some theoretical investigations show that near- and below-threshold harmonic generation may originate from complex physical processes including the contribution from different trajectories[Reference Li, Sheu, Laughlin and Chu31–Reference Xiong, Geng, Tang, Peng and Gong33], in our work we can clearly see that the 3rd harmonic signal generated from either the excited state [Figure 3(a)] or the ground state [Figure 3(b)] can be well explained by the perturbative theory. In contrast, the 7th harmonic signal generated from the excited argon with the pump–probe scheme shows large deviations from the $I^{7}$ law predicted by the perturbation theory. Instead, a nearly linear dependence of the 7th harmonic on the intensity of the probe beam is observed. Furthermore, we have noticed that the threshold intensity for generating the 7th harmonics from the ground-state argon atoms is ${\sim}21$ times as high as that from the pre-excited argon atoms.
An additional evidence to support the nonperturbative picture for the above-threshold harmonic is the observed strong dependence of the above-threshold harmonic (i.e., 7th harmonic) on the ellipticity of the driving laser pulses. In the perturbative regime, the dependence of harmonics on the ellipticity of the polarization of the pump pulses can be expressed by $I_{q}=[(1-\unicode[STIX]{x1D700}^{2})/(1+\unicode[STIX]{x1D700}^{2})]^{q-1}$ [Reference Liang, Ammosov and Chin27]. Using the expression, we calculate the ellipticity dependence of both the 3rd and 7th harmonics, which are shown as the green solid and blue dashed curves in Figure 4. The experimental result and the prediction from the perturbative theory agree very well for the 3rd harmonic signal. However, for the above-threshold harmonic (i.e., 7th harmonic) generation, the deviation between the experimental result and perturbative theory implies again that the 7th harmonic generation should originate from the nonperturbative process rather than the perturbative process. In the three-step model of HHG, the ellipticity dependence is a result of the diffusive wavepacket dynamics of the electrons in the combined Coulomb and laser fields, which will be investigated in the future.
Based on the experimental results and discussions mentioned above, we provide the general physical picture for the observed harmonics generated from the excited-state argon atoms, which is shown in Figure 5. In the first step, the pump pulses efficiently excite the argon atoms into a long-life metastable state $\text{Ar}^{\ast }(4\,^{3}P_{2})$ , which is caused by a two-step kinetic process including of three-body collisions and dissociation recombination. For the reasons mentioned above, the contribution from the ground state of argon to the HHG is negligible in the pump–probe measurements. The 3rd harmonic generation from the excited-state argon atoms is obviously a perturbative nonlinear process. In contrast, a nonperturbative process (labelled as ➁ shown in Figure 5) is suggested to be responsible for the above-threshold harmonic generation, i.e., an electron from the excited state is ionized by the probe laser pulses, and then finally recombined with parent ion after being accelerated and driven back in the oscillating laser field. In the framework of semiclassical three-step model, many complex processes are involved in above-threshold harmonics generation from pre-excited atoms, including the interference between short trajectory and long trajectory, multi-scattering, resonant effects and so on[Reference Li, Sheu, Laughlin and Chu31]. To clarify the complex nonperturbative process, more efforts will focus on the numerical calculations in the future.
5 Conclusion
In conclusion, we have experimentally investigated the above-threshold (i.e., 7th) harmonic generated from the excited argon atoms using mid-infrared femtosecond laser pulses. By comparing the dependences of the above-threshold and below-threshold harmonic signals on the driving laser parameters, our results demonstrate that the below-threshold harmonic generation can be well understood in the framework of the perturbative theory, whereas the above-threshold harmonics should be generated essentially through the nonperturbative three-step process. Our work motivates the investigations on various extreme nonlinear optical processes in the excited atoms/molecules, opening the possibility for obtaining the spatial and temporal information of excited atoms/molecules with resolutions on the atomic scales.
Acknowledgements
This work is supported by the National Basic Research Program of China (No. 2014CB921300), the National Natural Science Foundation of China (Nos. 11127901, 11134010, 61575211, 11304330, 11404357, 61405220, 61605227, and 61705034), and the Shanghai ‘Yang Fan’ Program (Nos. 14YF1406100 and 16YF1412700).