No CrossRef data available.
Article contents
The Effect of Contact Implants on the Patterning of Tungsten Damascene Interconnects
Published online by Cambridge University Press: 15 February 2011
Abstract
Contact implants can increase the etch rate of BPSG during HF precleans used prior to metallization. As a result, troughs form in the implanted BPSG that can trap metal and cause leakage between interconnects. It is shown that the increase in HF etch rate is especially pronounced for BF2, implants, due to the presence of F. The topography, and hence the leakage, can be reduced by capping the BPSG with an undoped oxide prior to implantation.
- Type
- Research Article
- Information
- Copyright
- Copyright © Materials Research Society 1996
References
1.
Kaanta, C. W., Bombardier, S. G., Cote, W. J., Hill, W. R., Kerszykowski, G., Landis, H. S., Poindexter, D. J., Pollard, C. W., Ross, G. H., Ryan, J. G., Wolff, S., and Cronin, J. E., VMIC Conf. Proc.,1991, p. 144.Google Scholar
2.
Roehl, S., Camilletti, L., Cote, W., Cote, D., Eckstein, E., Froehner, K. H., Lee, P. I., Restaino, D., Roeska, G., Vynorius, V., Wolff, S., and Vollmer, B., VMIC Conf. Proc., 1992, p. 22.Google Scholar
4.
Landers, W., Cote, B., Miura, D., Sandwick, T., Vollmer, B., and Vynorius, V., presented at the International Conference on Metallurgical Coatings and Thin Films, San Diego, 1995.Google Scholar
6.
Kern, W. and Deckert, C. A., in Thin Film Processes, edited by Vossen, J. L. and Kern, W., (Academic Press, NY, 1978), p. 401.Google Scholar