Abstract
Changes in mass density of amorphous Pd80Si20 were monitored in situ during irradiation with He2+ and H+ ions at temperatures below 100 K and during subsequent thermal treatment. The mass density decreased with increasing ion fluence and exponentially approached a saturation value of −1.2%, corresponding to a recombination volume of 190 atomic volumes. The initial swelling rate was 2.3 atomic volumes/displaced atom. The mass density of the irradiated material increased during subsequent thermal treatment, and the irradiation-induced decrease of the mass density recovered completely at room temperature.