Skip to main content Accessibility help
×
Hostname: page-component-78c5997874-g7gxr Total loading time: 0 Render date: 2024-11-03T02:02:19.011Z Has data issue: false hasContentIssue false

4 - Inelastic scattering and the resolution function

Published online by Cambridge University Press:  19 August 2009

Gen Shirane
Affiliation:
Brookhaven National Laboratory, New York
Stephen M. Shapiro
Affiliation:
Brookhaven National Laboratory, New York
John M. Tranquada
Affiliation:
Brookhaven National Laboratory, New York
Get access

Summary

One of the chief strengths of the triple-axis spectrometer is its ability to measure the intensity of scattered neutrons for a particular momentum transfer Q0 and energy transfer ħω0. This capability is especially important for measurements of inelastic scattering from single crystals. With a computer-controlled spectrometer, it is a simple matter to scan the energy transfer while sitting at a specific point in reciprocal space. Conversely, one may choose to scan the spectrometer along a particular direction in reciprocal space while maintaining a constant energy transfer. Such scans are easily interpreted, both qualitatively and quantitatively, as we will discuss.

Of course, because of the small scattering cross section for neutrons and the limited neutron flux generally available, one must typically perform measurements with finite beam divergences and with monochromator and analyzer crystals having significant mosaic widths. As a result, the energy and momentum transfers of the neutrons are distributed within some small region about the average values (ω0, Q0). It is possible to describe the measured signal as a convolution of a spectrometer resolution function R(QQ0, ω–ω0) and the scattering function S(Q, ω). The resolution function is peaked at (ω0, Q0) and decreases for deviations (Δω, ΔQ). The constant-amplitude contours for the resolution function form a set of nested ellipsoids in (ω, Q) space and, for a given spectrometer configuration, the volume, shape, and orientation of these ellipsoids depend only on (ω0, Q0). The form of the measured spectra will depend on the way in which the resolution function is scanned through the structures defined by the scattering function. With some basic knowledge about the resolution function one can optimize scans to obtain sharper spectra and a better signal-to-noise ratio.

Type
Chapter
Information
Publisher: Cambridge University Press
Print publication year: 2002

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Save book to Kindle

To save this book to your Kindle, first ensure [email protected] is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×