Skip to main content Accessibility help
×
Hostname: page-component-cd9895bd7-jn8rn Total loading time: 0 Render date: 2024-12-24T17:54:36.430Z Has data issue: false hasContentIssue false

Section 2 - Basic Airway Management

Published online by Cambridge University Press:  03 March 2017

D. John Doyle
Affiliation:
Cleveland Clinic, Abu Dhabi
Basem Abdelmalak
Affiliation:
Cleveland Clinic, Ohio
Get access
Type
Chapter
Information
Clinical Airway Management
An Illustrated Case-Based Approach
, pp. 39 - 68
Publisher: Cambridge University Press
Print publication year: 2000

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

References

American Society of Anesthesiologists Task Force on Sedation and Analgesia by Non-Anesthesiologists. Practice guidelines for sedation and analgesia by non-anesthesiologists. Anesthesiology. 2002;96(4):1004–17.Google Scholar
American Society of Anesthesiologists (ASA). Standards for basic anesthetic monitoring. (Approved by the ASA House of Delegates on October 21, 1986, and last amended on October 20, 2010). Cited Feb 24, 2014. Available from https://www.asahq.org/For-Members/Standards-Guidelines-and-Statements.aspx.Google Scholar
American Society of Anesthesiologists (ASA). Continuum of depth of sedation: Definition of general anesthesia and levels of sedation/analgesia, 2009. (Updated 2009). Cited Feb 24, 2014. Available from https://www.asahq.org/.../2012/CONTINUUM OF DEPTH OF SEDATION 442012/en/1.Google Scholar
American Society of Anesthesiologists (ASA). Statement on granting privileges to nonanesthesiologist practitioner for administering moderate sedation. (Approved by the ASA House of Delegates on October 25, 2005, and last amended on October 19, 2011.) Cited Feb 8, 2015. Available from https://www.asahq.org/resources/standards-and-guidelines.Google Scholar
Center for Medicaid and Medicaire Services (CMS). Interpretive guidelines for hospitals regarding anesthesia services. Cited 2012 Feb 22, 2014. Available from https://www.cms.gov/Regulations-and-Guidance/Guidance/Transmittals/downloads/R74SOMA.pdf.Google Scholar
Patel, S, Vargo, JJ, Khandwala, F, Lopez, R, Trolli, P, Dumot, JA, et al. Deep sedation occurs frequently during elective endoscopy with meperidine and midazolam. Am J Gastroenterol. 2005;100(12):2689–95.CrossRefGoogle ScholarPubMed
Vargo, JJ, Zuccaro, G, Dumot, JA, Conwell, DL, Morrow, JB, Shay, SS. Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy. Gastrointest Endosc. 2002;55(7):826–31.CrossRefGoogle ScholarPubMed
Qadeer, MA, Vargo, JJ, Dumot, JA, Lopez, R, Trolli, PA, Stevens, T, et al. Capnographic monitoring of respiratory activity improves safety of sedation for endoscopic cholangiopancreatography and ultrasonography. Gastroenterology. 2009;136(5):1568–76; quiz 819–20.CrossRefGoogle ScholarPubMed

References

Meduna, L. General discussions of the cardiozol therapy. Am. J. Psychiatry 94:4050. 1938.CrossRefGoogle Scholar
Valentine, M, Keddie, KMG, Dunne, D. Comparison techniques in electroconvulsive therapy. Br. J. Psychiatry 114:989–94. 1968.CrossRefGoogle Scholar
Abrams, R. ECT for Parkinson's disease. Am. J. Psychiatry 146(11):1391–3. 1989.Google ScholarPubMed
Bennett, AE. The introduction of curare into clinical medicine; present and potential usefulness. Am. Sci. 34:424–31. 1946.Google ScholarPubMed
Holt, WL, et al. A comparative study of Flaxedil and Syncurine combined with pentothal anesthesia in modifying electroconvulsive therapy. Am. J. Psychiatry 109(10):749–56. 1953.CrossRefGoogle ScholarPubMed
Bennett, AE. Preventing traumatic complications in convulsive shock therapy by curare. JAMA 114:322–4. 1940.Google Scholar
Boutros, A, Pevlicek, W. Anesthesia for magnetic resonance imaging. Anesth. Analg. 66:367. 1987.CrossRefGoogle ScholarPubMed

References

Brimacombe, J. The advantages of the LMA over the tracheal tube or face mask: a meta-analysis. Can J Anaesth 1995; 42: 1017–23.CrossRefGoogle ScholarPubMed
Cook, TM, Woodall, N, Frerk, C. Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: anaesthesia. Br J Anaesth 2011; 106: 617–31.Google Scholar
Cook, T, Howes, B. Supraglottic airway devices: recent advances. BJA CEACCP 2011; 11: 5761.Google Scholar
Pandit, JJ, Popat, MT, Cook, TM, et al. The Difficult Airway Society ‘ADEPT’ guidance on selecting airway devices: the basis of a strategy for equipment evaluation. Anaesthesia 2011; 66: 726–37.CrossRefGoogle Scholar
Cook, TM, Lee, G, Nolan, JP. The ProSeal laryngeal mask airway: a review of the literature. Can J Anaesth 2005; 52: 739–60.Google ScholarPubMed
Brimacombe, J, Keller, C, Judd, DV. Gum elastic bougie-guided insertion of the ProSeal laryngeal mask airway is superior to the digital and introducer tool techniques. Anesthesiology 2004; 100: 25–9.CrossRefGoogle Scholar
Chen, X, Jiao, J, Cong, X, Liu, L, Wu, X. A comparison of the performance of the i-gel™ vs. the LMA-S™ during anesthesia: a meta-analysis of randomized controlled trials. PLoS One 2013; 8: e71910.CrossRefGoogle ScholarPubMed
Verghese, C, Brimacombe, JR. Survey of laryngeal mask airway usage in 11,910 patients: safety and efficacy for conventional and nonconventional usage. Anesth Analg 1996; 82: 129–33.Google Scholar
Cook, TM, Gibbison, B. Analysis of 1000 consecutive uses of the ProSeal laryngeal mask airway by one anaesthetist at a district general hospital. Br J Anaesth 2007; 99: 436–9.CrossRefGoogle Scholar
Cook, TM, Gatward, JJ, Handel, J, et al. The evaluation of the LMA Supreme™ in 100 non-paralysed patients. Anaesthesia 2009; 64: 555–62.CrossRefGoogle ScholarPubMed
Theiler, L, Gutzmann, M, Kleine-Brueggeney, M, Urwyler, N, Kaempfen, B, Greif, R. i-gel™ supraglottic airway in clinical practice: a prospective observational multicentre study. Br J Anaesth 2012; 109: 990–5.CrossRefGoogle ScholarPubMed
Brimacombe, J. Placement phase. In Laryngeal Mask Anaesthesia: Principles and Practice, 2nd edition, 2005. London: Saunders; pp. 191240.Google Scholar
Brimacombe, J. Problems. In Laryngeal Mask Anaesthesia: Principles and Practice, 2nd edition, 2005. London: Saunders; pp. 551–76.Google Scholar
Brimacombe, J. Resuscitation. In Laryngeal Mask Anaesthesia: Principles and Practice, 2nd edition, 2005. London: Saunders: pp. 281–96.Google Scholar
Hohlrieder, M, Brimacombe, J, von Goedecke, A, Keller, C. Guided insertion of the ProSeal laryngeal mask airway is superior to conventional tracheal intubation by first-month anesthesia residents after brief manikin-only training. Anesth Analg 2006; 103: 458–62.CrossRefGoogle ScholarPubMed
Howes, BW, Wharton, NM, Gibbison, B, Cook, TM. LMA Supreme insertion by novices in manikins and patients. Anaesthesia 2010: 65; 343–7.CrossRefGoogle ScholarPubMed
Wharton, NM, Gibbison, B, Gabbott, D, Haslam, GM, Cook, TM. i-gel insertion by novices in manikins and patients. Anaesthesia 2008; 63: 991–5.CrossRefGoogle ScholarPubMed
Gatward, JJ, Cook, TM, Seller, C, et al. Evaluation of the size 4 i-gel airway in one hundred non-paralysed patients. Anaesthesia 2008; 63: 1124–30.CrossRefGoogle ScholarPubMed
Scanlon, P, Carey, M, Power, M, Kirby, F. Patient response to laryngeal mask insertion after induction of anaesthesia with propofol or thiopentone. Can J Anaesth 1993; 40: 816–18.CrossRefGoogle ScholarPubMed
Goyagi, T, Tanaka, M, Nishikawa, T. Fentanyl decreases propofol requirement for laryngeal mask airway insertion. Acta Anaesthesiol Scand 2003; 47: 771–4.CrossRefGoogle ScholarPubMed
Baik, HJ, Kim, YJ, Kim, JH. Lidocaine given intravenously improves conditions for laryngeal mask airway insertion during propofol target-controlled infusion. Eur J Anaesthesiol 2009; 26: 377–81.CrossRefGoogle ScholarPubMed
Kodaka, M, Handa, F, Kawasaki, J, Miyao, H. Cp50 of propofol for laryngeal mask airway insertion using predicted concentrations with and without nitrous oxide. Anaesthesia 2002; 57: 956–9.CrossRefGoogle ScholarPubMed
Drage, MP, Nunez, J, Vaughan, RS, Asai, T. Jaw thrusting as a clinical test to assess the adequate depth of anaesthesia for insertion of the laryngeal mask. Anaesthesia 1996; 51: 1167–70.CrossRefGoogle ScholarPubMed
Keller, C, Sparr, HJ, Brimacombe, JR. Positive pressure ventilation with the laryngeal mask airway in non-paralysed patients: comparison of sevoflurane and propofol maintenance techniques. Br J Anaesth 1998; 80: 332–6.CrossRefGoogle ScholarPubMed
Cook, TM, Kelly, FE. Time to abandon the ‘vintage’ LMA and adopt 2nd-generation SADs as 1st choice. Br J Anaesth 2015; 115: 497–9.CrossRefGoogle Scholar

References

Fiadjoe, J.E. and Stricker, P.A., Shedding new light on an old technique. Anesthesiology, 2013. 118(5): 1011–2.CrossRefGoogle Scholar
Langeron, O., et al., Prediction of difficult mask ventilation. Anesthesiology, 2000. 92(5): 1229–36.CrossRefGoogle ScholarPubMed
Mallampati, S.R., et al., A clinical sign to predict difficult tracheal intubation: a prospective study. Canadian Anaesthetists’ Society Journal, 1985. 32(4): 429–34.Google ScholarPubMed
Cormack, R.S. and Lehane, J., Difficult tracheal intubation in obstetrics. Anaesthesia, 1984. 39(11): 1105–11.CrossRefGoogle ScholarPubMed
Adnet, F., et al., The intubation difficulty scale (IDS): proposal and evaluation of a new score characterizing the complexity of endotracheal intubation. Anesthesiology, 1997. 87(6): 1290–7.Google ScholarPubMed
Magill, I.W., Technique in endotracheal anaesthesia. BMJ, 1930. 2(3645): 817–19.CrossRefGoogle ScholarPubMed
El-Orbany, M., Woehlck, H., and Salem, M.R., Head and neck position for direct laryngoscopy. Anesth Analg, 2011. 113(1): 103–9.CrossRefGoogle ScholarPubMed
Bannister, F.B. and Macbeth, R.G., Direct laryngoscopy and tracheal intubation. Lancet, 1944. 250 (2): 651–4.Google Scholar
Zvara, D.A., Calicott, R.W., and Whelan, D.M., Positioning for intubation in morbidly obese patients. Anesth Analg, 2006. 102(5): 1592.CrossRefGoogle ScholarPubMed
Rao, S.L., et al., Laryngoscopy and tracheal intubation in the head-elevated position in obese patients: a randomized, controlled, equivalence trial. Anesth Analg, 2008. 107(6): 1912–18.CrossRefGoogle ScholarPubMed
Amour, J., et al., Comparison of single-use and reusable metal laryngoscope blades for orotracheal intubation during rapid sequence induction of anesthesia: a multicenter cluster randomized study. Anesthesiology, 2010. 112(2): 325–32.CrossRefGoogle ScholarPubMed
Rassam, S., et al., A comparison of 20 laryngoscope blades using an intubating manikin: visual analogue scores and forces exerted during laryngoscopy. Anaesthesia, 2005. 60(4): 384–94.CrossRefGoogle ScholarPubMed
Arino, J., et al., Straight blades improve visualization of the larynx while curved blades increase ease of intubation: a comparison of the Macintosh, Miller, McCoy, Belscope and Lee-Fiberview blades. Can J Anesth, 2003. 50(5): 501–6.CrossRefGoogle ScholarPubMed
Lim, M., Demspey, C., and Pead, M., Choosing a laryngoscope blade: straight vs curved. Can J Anesth, 2003. 50(10): 1078–9.CrossRefGoogle ScholarPubMed
Scott, J. and Baker, P.A., How did the Macintosh laryngoscope become so popular? Paediatr Anaesth, 2009. 19: 24–9.CrossRefGoogle ScholarPubMed
Arino, J., et al., Reply. Can J Anesth, 2003. 50(10): 1079–80.CrossRefGoogle Scholar
Scott, J. and Baker, P.A., How did the Macintosh laryngoscope become so popular? Paediatr Anaesth, 2009. 19 Suppl 1: 24–9.CrossRefGoogle ScholarPubMed
Levitan, R.M., et al., Light intensity of curved laryngoscope blades in Philadelphia emergency departments. Ann Emerg Med, 2007. 50(3): 253–7.CrossRefGoogle ScholarPubMed
Miller, R.A., A new laryngoscope. Anesthesiology, 1941. 2(3): 317–20.CrossRefGoogle Scholar
Lagade, M.R. and Poppers, P.J., Revival of the polio laryngoscope blade. Anesthesiology, 1982. 57(6): 545.CrossRefGoogle ScholarPubMed
Gabbott, D.A., Laryngoscopy using the McCoy laryngoscope after application of a cervical collar. Anaesthesia, 1996. 51(9): 812–14.CrossRefGoogle ScholarPubMed
McCoy, E.P. and Mirakhur, R.K., The levering laryngoscope. Anaesthesia, 1993. 48(6): 516–19.CrossRefGoogle ScholarPubMed
McCoy, E.P., Mirakhur, R.K., and McCloskey, B.V., A comparison of the stress response to laryngoscopy. The Macintosh versus the McCoy blade. Anaesthesia, 1995. 50(11): 943–6.CrossRefGoogle ScholarPubMed
McCoy, E.P., et al., A comparison of the forces exerted during laryngoscopy. The Macintosh versus the McCoy blade. Anaesthesia, 1996. 51(10): 912–15.CrossRefGoogle ScholarPubMed
Negri de Sousa, A.C., Levy, C.E., and Freitas, M.I., Laryngoscope blades and handles as sources of cross-infection: an integrative review. J Hosp Infect, 2013. 83(4): 269–75.CrossRefGoogle ScholarPubMed
Asai, T., Video laryngoscopes: do they truly have roles in difficult airways? Anesthesiology, 2012. 116(3): 515–17.Google ScholarPubMed
Tamura, M.M.D., et al., Mandibular advancement improves the laryngeal view during direct laryngoscopy performed by inexperienced physicians. Anesthesiology, 2004. 100(3): 598601.CrossRefGoogle ScholarPubMed
Knill, R.L., Difficult laryngoscopy made easy with a “BURP”. Can J Anaesth, 1993. 40(3): 279–82.CrossRefGoogle ScholarPubMed
Yamamoto, K.M.D., et al., Left-molar approach improves the laryngeal view in patients with difficult laryngoscopy. Anesthesiology, 2000. 92(1): 70.CrossRefGoogle ScholarPubMed
Hudson, J., Vu, M., and Vu, E., Successful intubation using retrograde trans-tracheal illumination after laryngoscope light source failure. Br J Anaesth, 2010. 105(1): 96–7.CrossRefGoogle ScholarPubMed
Yang, T.M.D.P.D., et al., Retrograde light-guided laryngoscopy for tracheal intubation: clinical practice and comparison with conventional direct laryngoscopy. Anesthesiology, 2013. 118(5): 1059–64.CrossRefGoogle ScholarPubMed

References

Cooper, R. Is direct laryngoscopy obsolete? Internet Journal of Airway Management. 2007 July 9;4.Google Scholar
Miller, R. A new laryngoscope. Anesthesiology. 1941;2(3):317–20.CrossRefGoogle Scholar
Bailey, B. Laryngoscopy and laryngoscopes – who's first? The forefathers/four fathers of laryngology. Laryngoscope. 1996 Aug;106(8):939–43.CrossRefGoogle ScholarPubMed
Macintosh, R. A new laryngoscope. Lancet. 1943;1:205.CrossRefGoogle Scholar
McIntyre, JW. Laryngoscope design and the difficult adult tracheal intubation. Can J Anaesth. 1989 Jan;36(1):94–8.CrossRefGoogle ScholarPubMed
Marks, RR, Hancock, R, Charters, P. An analysis of laryngoscope blade shape and design: new criteria for laryngoscope evaluation. Can J Anaesth. 1993 Mar;40(3):262–70.CrossRefGoogle ScholarPubMed
Arino, JJ, Velasco, JM, Gasco, C, Lopez-Timoneda, F. Straight blades improve visualization of the larynx while curved blades increase ease of intubation: a comparison of the Macintosh, Miller, McCoy, Belscope and Lee-Fiberview blades. Can J Anaesth. 2003 May;50(5):501–6.CrossRefGoogle ScholarPubMed
Greenland, KB, Eley, V, Edwards, MJ, Allen, P, Irwin, MG. The origins of the sniffing position and the Three Axes Alignment Theory for direct laryngoscopy. Anaesth Intensive Care. 2008 Jul;36(Suppl 1):23–7.CrossRefGoogle ScholarPubMed
Levitan, RM, Heitz, JW, Sweeney, M, Cooper, RM. The complexities of tracheal intubation with direct laryngoscopy and alternative intubation devices. Ann Emerg Med. 2011 Mar;57(3):240–7.CrossRefGoogle ScholarPubMed
Cheyne, DR, Doyle, P. Advances in laryngoscopy: rigid indirect laryngoscopy. F1000 Med Rep. 2010;2:61.CrossRefGoogle ScholarPubMed
Pott, LM, Murray, WB. Review of video laryngoscopy and rigid fiberoptic laryngoscopy. Curr Opin Anaesthesiol. 2008 Dec;21(6):750–8.CrossRefGoogle ScholarPubMed
Sakles, JC, Rodgers, R, Keim, SM. Optical and video laryngoscopes for emergency airway management. Intern Emerg Med. 2008 Jun;3(2):139–43.CrossRefGoogle ScholarPubMed
Hurford, WE. The video revolution: a new view of laryngoscopy. Respir Care. 2010 Aug;55(8):1036–45.Google ScholarPubMed
Griesdale, DE, Liu, D, McKinney, J, Choi, PT. Glidescope(R) video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis. Can J Anaesth. 2012 Jan;59(1):4152.CrossRefGoogle Scholar
Healy, DW, Maties, O, Hovord, D, Kheterpal, S. A systematic review of the role of videolaryngoscopy in successful orotracheal intubation. BMC Anesthesiol. 2012;12:32.CrossRefGoogle ScholarPubMed
Agro, F, Barzoi, G, Montecchia, F. Tracheal intubation using a Macintosh laryngoscope or a GlideScope in 15 patients with cervical spine immobilization. Br J Anaesth. 2003 May;90(5):705–6.CrossRefGoogle ScholarPubMed
Cooper, RM. Use of a new videolaryngoscope (GlideScope) in the management of a difficult airway. Can J Anaesth. 2003 Jun–Jul;50(6):611–13.CrossRefGoogle ScholarPubMed
Cooper, RM. The GlideScope videolaryngoscope. Anaesthesia. 2005 Oct;60(10):1042.CrossRefGoogle ScholarPubMed
Cooper, RM, Pacey, JA, Bishop, MJ, McCluskey, SA. Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients. Can J Anaesth. 2005 Feb;52(2):191–8.CrossRefGoogle ScholarPubMed
Doyle, DJ. Awake intubation using the GlideScope video laryngoscope: initial experience in four cases. Can J Anaesth. 2004 May;51(5):520–1.CrossRefGoogle ScholarPubMed
Doyle, DJ. GlideScope-assisted fiberoptic intubation: a new airway teaching method. Anesthesiology. 2004 Nov;101(5):1252.CrossRefGoogle ScholarPubMed
Rai, MR, Dering, A, Verghese, C. The GlideScope system: a clinical assessment of performance. Anaesthesia. 2005 Jan;60(1):60–4.CrossRefGoogle ScholarPubMed
Doyle, DJ. The GlideScope video laryngoscope. Anaesthesia. 2005 Apr;60(4):414–5.CrossRefGoogle ScholarPubMed
Walls, RM, Samuels-Kalow, M, Perkins, A. A new maneuver for endotracheal tube insertion during difficult GlideScope intubation. J Emerg Med. 2010 Jul;39(1):86–8.CrossRefGoogle ScholarPubMed
Corda, DM, Riutort, KT, Leone, AJ, Qureshi, MK, Heckman, MG, Brull, SJ. Effect of jaw thrust and cricoid pressure maneuvers on glottic visualization during GlideScope videolaryngoscopy. J Anesth. 2012 Jun;26(3):362–8.CrossRefGoogle ScholarPubMed
Cooper, RM. Complications associated with the use of the GlideScope videolaryngoscope. Can J Anaesth. 2007 Jan;54(1):54–7.CrossRefGoogle ScholarPubMed
Choo, MK, Yeo, VS, See, JJ. Another complication associated with videolaryngoscopy. Can J Anaesth. 2007 Apr;54(4):322–4.CrossRefGoogle ScholarPubMed
Vincent, RD Jr., Wimberly, MP, Brockwell, RC, Magnuson, JS. Soft palate perforation during orotracheal intubation facilitated by the GlideScope videolaryngoscope. J Clin Anesth. 2007 Dec;19(8):619–21.CrossRefGoogle ScholarPubMed
Hsu, WT, Hsu, SC, Lee, YL, Huang, JS, Chen, CL. Penetrating injury of the soft palate during GlideScope intubation. Anesth Analg. 2007 Jun;104(6):1609–10.CrossRefGoogle ScholarPubMed
Leong, WL, Lim, Y, Sia, AT. Palatopharyngeal wall perforation during GlideScope intubation. Anaesth Intensive Care. 2008 Nov;36(6):870–4.CrossRefGoogle ScholarPubMed
Hsu, WT, Tsao, SL, Chen, KY, Chou, WK. Penetrating injury of the palatoglossal arch associated with use of the GlideScope videolaryngoscope in a flame burn patient. Acta Anaesthesiol Taiwan. 2008 Mar;46(1):3941.CrossRefGoogle Scholar
Nestler, C, Reske, AP, Reske, AW, Pethke, H, Koch, T. Pharyngeal wall injury during videolaryngoscopyassisted intubation. Anesthesiology. 2013 Mar;118(3):709.CrossRefGoogle ScholarPubMed
Magboul, MM, Joel, S. The video laryngoscopes blind spots and possible lingual nerve injury by the Gliderite rigid stylet – case presentation and review of literature. Middle East J Anesthesiol. 2010 Oct;20(6):857–60.Google ScholarPubMed
Thong, S, Goh, S. Reported complications associated with the use of GlideScope® video laryngoscope: How can they be prevented? OA Anaesthetics. 2013 Mar 1;1(1):1.CrossRefGoogle Scholar
Weissbrod, PA, Merati, AL. Reducing injury during video-assisted endotracheal intubation: the “smart stylet” concept. Laryngoscope. 2011 Nov;121(11):2391–3.CrossRefGoogle ScholarPubMed
Aziz, MF, Healy, D, Kheterpal, S, Fu, RF, Dillman, D, Brambrink, AM. Routine clinical practice effectiveness of the GlideScope in difficult airway management: an analysis of 2,004 GlideScope intubations, complications, and failures from two institutions. Anesthesiology. 2011 Jan;114(1):3441.CrossRefGoogle ScholarPubMed
Dupanovic, M, Diachun, CA, Isaacson, SA, Layer, D. Intubation with the GlideScope videolaryngoscope using the “gear stick technique”. Can J Anaesth. 2006 Feb;53(2):213–14.CrossRefGoogle ScholarPubMed
Dow, WA, Parsons, DG. ‘Reverse loading’ to facilitate GlideScope intubation. Can J Anaesth. 2007 Feb;54(2):161–2.Google ScholarPubMed
Bader, SO, Heitz, JW, Audu, PB. Tracheal intubation with the GlidesScope videolaryngoscope, using a “J” shaped endotracheal tube. Can J Anaesth. 2006 Jun;53(6):634–5.CrossRefGoogle ScholarPubMed
Falcó-Molmeneu, E, Ramírez-Montero, F, Carreguí-Tusón, R, Santamaría-Arribas, N, Gallén-Jaime, T, Vila-Sánchez, M. The modified Eschmann guide to facilitate tracheal intubation using the GlideScope. Can J Anaesth. 2006 Jun;53(6): 633–4.CrossRefGoogle ScholarPubMed
Peral, D, Porcar, E, Bellver, J, Higueras, J, Onrubia, X, Barbera, M. Glidescope video laryngoscope is useful in exchanging endotracheal tubes. Anesth Analg. 2006 Oct;103(4):1043–4.CrossRefGoogle ScholarPubMed
Heitz, JW, Mastrando, D. The use of a gum elastic bougie in combination with a videolaryngoscope. J Clin Anesth. 2005 Aug;17(5):408–9.CrossRefGoogle ScholarPubMed
Kramer, DC, Osborn, IP. More maneuvers to facilitate tracheal intubation with the GlideScope. Can J Anaesth. 2006 Jul;53(7):737.CrossRefGoogle ScholarPubMed
Cho, JE, Kil, HK. A maneuver to facilitate endotracheal intubation using the GlideScope. Can J Anaesth. 2008 Jan;55(1):56–7.CrossRefGoogle ScholarPubMed
Conklin, LD, Cox, WS, Blank, RS. Endotracheal tube introducer-assisted intubation with the GlideScope video laryngoscope. J Clin Anesth. 2010 Jun;22(4):303–5.CrossRefGoogle ScholarPubMed
Sharma, R. A new maneuver for endotracheal tube insertion during difficult GlideScope(R) intubation: a suggestion. J Emerg Med. 2011 Apr;40(4):443; author reply 45.CrossRefGoogle Scholar
Xue, FS, Liu, HP, Xiong, J, Guo, XL, Liao, X. Facilitating smooth insertion of an endotracheal tube into the trachea under GlideScope((R)) video laryngoscope. J Emerg Med. 2011 Apr;40(4):443–4; author reply 45.CrossRefGoogle Scholar
Zeidan, A, Al-Temyatt, S. The use of Goldfinger(R) to facilitate glidescope tracheal intubation in a morbidly obese patient. Anesth Analg. 2011 Mar;112(3):738–9.CrossRefGoogle Scholar
Singh, M, Kumari, K, Kapoor, D, Singh, J.180 degrees upside down maneuver” for ease of endotracheal tube insertion with the GlideScope in patients with limited mouth opening. J Clin Anesth. 2013 May;25(3):243.CrossRefGoogle Scholar

Save book to Kindle

To save this book to your Kindle, first ensure [email protected] is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×