from (iii) - Intracranial cerebrovascular applications
Published online by Cambridge University Press: 05 July 2014
Introduction
Although insonation of cerebral veins in adults was attempted early in the 1990s (Hennerici, 1990; Mitchell, 1990; Furuhata, 1989), the intracerebral venous system has long been thought to be mostly inaccessible to transcranial sonography, due to its limitations in detection of low flow velocities, difficulties to separate these small signals from arterial ones and artefacts, poor angles of insonation and due to the high anatomical variance of the intracerebral venous system. In particular, the detection of cerebral veins and sinuses is difficult with conventional pulsed Doppler handheld probes, as the topography is concentrated along the midline structures and near the skull. In addition, venous diseases of the brain are much rarer than arterial diseases and treatment strategies are widely controversial (Bousser et al., 1985; Bousser & Russell, 1997).
New developments in ultrasound technology, particularly the introduction of transcranial colour-coded duplex system analysis and echocontrast enhancement have reduced some of these limitations and at least facilitated the analysis of intracerebral venous blood flow conditions. Using standard insonation pathways, venous signals can be identified from midline deep cerebral veins and some of the large draining sinuses from a transtemporal approach. The jugular vein and the sigmoid sinus including brainstem draining veins may be recorded from a transnuchal approach and the ophthalmic vein and the orbital draining plexus from a transorbital approach (Fig. 24.1). Normal flow velocity values are highly variable due to the diversity in topographic anatomy and also from variancies of insonation angles.
To save this book to your Kindle, first ensure [email protected] is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Find out more about the Kindle Personal Document Service.
To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.
To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.