A low-cost differential image motion monitor (DIMM), consisting of an 11-inch Celestron, an SBIG ST-4 autoguiding CCD camera and a PC, is described. Two such systems were used during June–July and November–December 1993 to make near-simultaneous seeing measurements at Freeling Heights in the Northern Flinders Ranges and at Siding Spring Observatory. The results of these campaigns show that the seeing-distribution is generally similar at both sites, with the most common seeing value being ~l·2″. Siding Spring does, however, have slightly more bad seeing (>2″) than Freeling Heights. Weather records from Arkaroola Resort (15 km south of Freeling Heights) indicate that there is ~15% less cloud cover at Freeling Heights than at Siding Spring. Episodes of rapid seeing deterioration at Siding Spring in winter are shown to coincide with warm air masses crossing the mountain.