We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
The main objective of this research work is to compare the dosimertic effect on lower and upper oesophagus cancer treatment using 3D conformal radiotherapy as well as to evaluate the doses administered to the organs at risk.
Materials and methods
In this study, a cohort of 30 oesophageal cancer patients between the ages of 45 and 67 years registered during March 2017 to February 2018 was considered. These patients were treated through 3D conformal radiotherapy using four-field technique. Beam energy of 15 MV from Varian DHX linear accelerator was used. The given 30 patients were divided into two groups. The 1st group of 15 patients with upper oesophagus cancer was prescribed 5000 cGy doses, and the 2nd group of remaining 15 patients with lower oesophagus cancer was prescribed 4500 cGy. Computed tomography scans of every patient were obtained and then transmitted to Eclipse TPS for generating treatment plans. All radiotherapy plans were evaluated through various dosimetric indices. Statistical analysis software SPSS was utilised to get the values of means standard error and standard deviation of these indices for the treatment plan evaluation.
Results
Uniformity index (UI) calculated for first group of patients showed difference of 7·4% from ideal value. A difference of 7% between ideal and calculated UI value was observed in 2nd group of patients. The values of other dosimetric indices like coverage, homogeneity, moderate dose homogeneity index (mDHI) and radical dose homogeneity index (rDHI) were found in limits specified by the Radiation Therapy and Oncology Group. The maximum difference of 6% was observed between the coverage mean values of 1st and 2nd group treatment plans.
Conclusion
For oesophageal cancer, 3D conformal radiotherapy using four-field treatment plans shows homogeneous distribution of dose around the target and limits the dose to organ at risk.