1. Error in the complex representation of the porous-coating model
The authors are grateful to Mr R. C. Tritarelli and Professor S. K. Lele for highlighting a significant error in their analysis of the stabilization effect of felt-metal coatings on hypersonic boundary layers (Fedorov et al. Reference Fedorov, Shiplyuk, Maslov, Burov and Malmuth2003).
As discussed in Tritarelli et al. (Reference Tritarelli, Lele and Fedorov2015), the complex representation of the porous-coating model used in Fedorov et al. (Reference Fedorov, Shiplyuk, Maslov, Burov and Malmuth2003) was in discordance with the time convention used in the normal-mode ansatz of the linear stability analysis. The numerical results from Fedorov et al. (Reference Fedorov, Shiplyuk, Maslov, Burov and Malmuth2003) are hereby negated.
For the sake of completeness, the corrected equations, which were already presented and discussed in Tritarelli et al. (Reference Tritarelli, Lele and Fedorov2015), are repeated in this corrigendum. For a detailed discussion we refer to Tritarelli et al. (Reference Tritarelli, Lele and Fedorov2015).
The equations describing the felt-metal porous-coating model in Fedorov et al. (Reference Fedorov, Shiplyuk, Maslov, Burov and Malmuth2003), i.e. equations (4.34)–(4.36), have to be substituted by
Additionally, the boundary conditions need to be replaced in order to be consistent with the time convention used. This implies that (4.31)–(4.33) should be reformulated as follows:
The corrected version of the figures of Fedorov et al. (Reference Fedorov, Shiplyuk, Maslov, Burov and Malmuth2003), which is presented in Tritarelli et al. (Reference Tritarelli, Lele and Fedorov2015), is partially reprinted in figures 1–3 in combination with the original erroneous results in order to show the impact of the corrected boundary conditions. Figures 1–3 present the corrected versions of figures 13, 14 and 17 of the original paper. For the correction of figures 15 and 16 we refer to Tritarelli et al. (Reference Tritarelli, Lele and Fedorov2015). The physical interpretations of the new results regarding the effect of felt-metal coatings on hypersonic boundary layers are discussed in Tritarelli et al. (Reference Tritarelli, Lele and Fedorov2015). In addition to the erroneous complex representation of the porous-coating model, several typographical errors existed in the original work, which are partially corrected in appendix A.
Appendix A. Typographical errors in Fedorov et al. (Reference Fedorov, Shiplyuk, Maslov, Burov and Malmuth2003)
In this appendix several typographical errors in Fedorov et al. (Reference Fedorov, Shiplyuk, Maslov, Burov and Malmuth2003) are corrected. The typographical errors listed in this appendix do not represent the totality of typographical errors present in Fedorov et al. (Reference Fedorov, Shiplyuk, Maslov, Burov and Malmuth2003).
The statement on p. 103 that the cone was rolled around its $X$ -axis was erroneous. The cone was rolled around its axis of symmetry in order to measure transverse distributions.
The position of the leading edge of the porous surface given on p. 104 was erroneous and should be replaced by $x^{\ast }=187~\text{mm}$ .
The definition of the non-dimensional Sutherland constant $S$ on p. 109 was erroneous and should be replaced by $S=110.4/T_{e}^{\ast }$ .
Furthermore, equations (4.19) and (4.20) of Fedorov et al. (Reference Fedorov, Shiplyuk, Maslov, Burov and Malmuth2003) are erroneous and $F_{0j}$ should be replaced by $F_{1j}$ , with $j\in \{1,3,4,5,7\}$ , in those equations.
In line 11 of p. 113 the definition of the frequency parameter should read $F={\it\omega}^{\ast }{\it\nu}_{e}^{\ast }/U_{e}^{\ast 2}={\it\omega}^{\ast }l^{\ast }/(U_{e}^{\ast }\,R)=1.2385\times 10^{-4}$ .
In addition, a typographical error was observed in the definition of ${\rm\Lambda}$ in equation (4.33) of Fedorov et al. (Reference Fedorov, Shiplyuk, Maslov, Burov and Malmuth2003), which reads
but does not correspond to the actual value used for numerical computations, i.e.
Likewise, the expression for $r_{p}^{\ast }$ in equation (4.39) of the original paper was erroneous and should be replaced by
In line 17 of p. 117 the units of the felt-metal resistivity need to be corrected and should read ${\it\sigma}^{\ast }=(1.66\pm 0.21)\times 10^{5}~\text{kg}~\text{m}^{-3}~\text{s}^{-1}$ .
In addition to the fact that the results for the porous-wall case in figures 15 and 16 were erroneous, the labels of these two figures were inaccurate. The corrected figures with the correct labels are presented in Tritarelli et al. (Reference Tritarelli, Lele and Fedorov2015).