Hostname: page-component-cd9895bd7-lnqnp Total loading time: 0 Render date: 2024-12-23T14:24:49.661Z Has data issue: false hasContentIssue false

Effect Of Implantation Temperature On Damage Accumulation In Ar - Implanted GaN

Published online by Cambridge University Press:  13 June 2014

I. Usov
Affiliation:
Curriculum in Applied and Materials Sciences, University of North Carolina at Chapel Hill
N. Parikh
Affiliation:
Curriculum in Applied and Materials Sciences, University of North Carolina at Chapel Hill
D.B. Thomson
Affiliation:
Department of Materials Science and Engineering, North Carolina State University
Robert F. Davis
Affiliation:
Department of Materials Science and Engineering, North Carolina State University

Abstract

A systematic investigation of damage accumulation in GaN films induced by Ar+ as a function of implantation temperature and dose rate has been conducted. Depth distribution of disorder was measured by Rutherford Backscattering/Channeling spectrometry. Two disordered regions were identified in the damage depth distribution: a surface peak and a bulk damage peak. These regions exhibited different behavior as a function of implantation temperature. The displaced atomic density in the bulk damage peak displayed a “reverse annealing” behavior in temperature range from 500 °C to 700 °C, which we attributed to formation of characteristic secondary defects. The influence of implantation temperature and dose rate on the radiation damage accumulation is discussed.

Type
Research Article
Copyright
Copyright © 2002 Materials Research Society

1. Introduction

Due to its outstanding properties, GaN plays a significant role in modern semiconductor physics and technology. In order to realize the advantage of GaN, controllable doping and formation of semi insulating layers must be achieved. Ion implantation is the only technique presently available for planar selective area doping of GaN Reference Papanicolau, Rao, Molnar, Tucker, Edwards, Holland and Ridgway[1]. The introduction of dopants into solids by ion implantation is accompanied by radiation damage of the crystalline lattice, which has to be recovered via annealing treatments. It has been demonstrated that the removal of implantation damage in GaN requires annealing temperatures above 1500 °C and is complicated by material decomposition due to nitrogen evaporation Reference Pearton, Zolper, Shul and Ren[2]. One way to facilitate the annealing process is to reduce the damage concentration by performing the ion implantation at elevated temperatures. It has been shown in a number of papers that ion implantation at temperatures (Timp) up to 550 °C reduces the amount of radiation damage in comparison to room temperature (RT) Reference Kucheyev, Williams, Zou, Jagadish and Li[3] Reference Liu, Wenzel, Volz and Rauschenbach[4] Reference Parikh, Suvkhanov, Lioubtchenko, Carlson, Bremser, Bray, Davis and Hunn[5]. In contrast, a report by Wenzel et al. Reference Wenzel, Liu and Rauschenbach[6] indicated that the lattice disorder measured by Rutherford Backscattering/Channeling spectrometry (RBS/C) in GaN implanted with Mg+ increased with increasing implantation temperature from RT to 550 °C. The main intention of the present study, therefore, was to investigate in detail the dependence on the implantation temperature of the amount of damage produced in GaN over a wide temperature range.

2. Experimental Details

For the present investigation, epitaxial GaN films (1.0 − 1.5 μm thick) were grown on (0001) 6H-SiC substrates by MOVPE deposition. Implantation with 150 keV Ar+ was performed at temperatures ranging from RT to 1000 °C, to a dose of 3×1015 cm−2 and a dose rate 0.45 and 4.5 μA/cm2. During implantation the tilt angle between the ion beam direction and the sample surface was set to 5 ° to avoid channeling effects. Samples were mounted onto a graphite strip, which was heated by passing an AC current through it. The heater temperature calibration was carried out by an optical pyrometer and Pt/Pt-10%Rh thermocouple. The ion-induced damage was determined by means of RBS/C with 2.3 MeV He+ ions aligned along <0001> axis of the GaN sample and a scattering angle of 108°.

3. Results and Discussions

Figures 1a - 1c depict the aligned RBS spectra obtained from the as-grown sample and from samples that were implanted with 150 keV Ar+ to the dose of 3×1015 cm−2 at the dose rate 0.45 μA/cm2 over the temperature range from RT to 1000 °C. For visualization of the RBS/C spectra, the temperature range has been divided into three groups and the data are shown in separate plots. A significant feature in these figures is that the yield of backscattering ions shows two distinct regions, which behave differently with the change of implantation temperature. The first region corresponds to the sharp surface peak, which arose from the scattering from Ga atoms located at the sample surface and reflects an amount of disorder on the surface. The height of the surface peak decreases with increasing implantation temperature and approaches the magnitude of the unimplanted sample. The second region is located at the energies 1.6 − 1.9 MeV and represents the peak resulting from direct scattering from the displaced Ga atoms in the sample bulk. The figures clearly show that backscattering yield in the bulk peak region decrease with increasing Timp up to 500 °C (see Figure 1a). Implantation at higher temperatures results in a retrograde behavior of the backscattering yield with temperature. Irradiation in the temperature range between 500 °C and 700 °C leads to an increase in the yield (see Figure 1b), which we refer to as the “reverse annealing” regime and further increase of the temperature decreases the backscattering yield (see Figure 1c).

Figure 1a. RBS/C spectra of GaN implanted with 150 keV Ar+ to the dose of 3×1015 cm−2 at different temperatures: RT - [square](red), 150 °C - ^ (green), 300 °C - Δ (dark blue), 500 °C - + (light blue). Black solid line corresponds to an unimplanted sample.

Figure 1b. RBS/C spectra of GaN implanted with 150 keV Ar+ to the dose of 3×1015 cm−2 at different temperatures: 500 °C - + (light blue), 600 °C - ∇ (dark blue), 700 °C - ✧ (green). Black solid line corresponds to an unimplanted sample.

Figure 1c. RBS/C spectra of GaN implanted with 150 keV Ar+ to the dose of 3×1015 cm−2 at different temperatures: 700 °C - ✧ (green;, 800 °C -[square] (red), 900 °C - * (dark blue), 1000 °C - Δ (light blue). Black solid line corresponds to an unimplanted sample.

These results are very unexpected because usually, as the implantation temperature increases one observes a decrease of disorder. RBS/C studies of Si, Ge and GaAs implanted at elevated temperatures with various ions, at a wide range of energies and ion doses have demonstrated that an increase of the implantation temperature always results in a decrease of the concentration of radiation-induced defects Reference Eriksson, Davies, Johansson and Mayer[7] Reference Picraux, Westmoreland, Mayer, Hart and Marsh[8] Reference Hynes and Holland[9]. We believe that the retrograde behavior of the damage density as a function of implantation temperature observed in GaN is due to the fact that damage accumulation under bombardment in this material proceeds by a mechanism different from the mechanism which takes place in the above-mentioned materials. It is plausible that, due to the high dynamic annealing rate, characteristic secondary defects are formed in the narrow temperature interval just before the temperature at which the disorder begins to drop, and that these defects cause significant displacement of atoms from regular lattice sites, as registered by RBS/C.

The depth distribution of defects in the bulk damage peak, Nd(z), was estimated by applying the linear dechanneling approximation Reference Feldman, Mayer and Picraux[10]:

(1)

where N0 is the atomic density in the Ga sublattice, χd and χr are the measured normalized yield in the damaged crystal and the calculated dechanneled fraction, respectively.

The defect profiles obtained from equation 1 are shown in Figures 2a - 2c. The bulk damage peak resembles a Gaussian-like profile centered at 90 ± 10 nm for Timp up to 500 °C (see Figure 2a). The increase of Timp from RT to 500 °C results not only in annihilation of radiation defects but also in their diffusion into the sample bulk. When the implantation conditions favorable for the reverse annealing regime were achieved, the maximum of the damage peak shifted deeper into the bulk and was situated at 113 ± 10 nm for irradiation at Timp= 700 °C (see Figure 2b). Further increase of implantation temperature to 1000 °C reduces the amount of disorder (see Figure 2c). At Timp ≥ 800 °C the maximum of the bulk damage peak shifts back to the surface, presumably due to evaporation of a thin surface layer. Analysis of GaN evaporation during high-temperature ion implantation will be reported elsewhere.

Figure 2a. The depth distribution of damage, Nd(z), in GaN implanted with 150 keV Ar+ at different implantation temperatures obtained using equation 1: RT - [square] (red), 150 °C - o (green), 300 °C - Δ (dark blue), 500 °C - + (light blue).

Figure 2b. The depth distribution of damage, Nd(z), in GaN implanted with 150 keV Ar+ at different implantation temperatures obtained using equation 1: 500 °C - + (light blue), 600 °C - ∇ (dark blue), 700 °C - ✧ (green).

Figure 2c. The depth distribution of damage, Nd(z), in GaN implanted with 150 keV Ar+ at different implantation temperatures obtained using equation 1: 700 °C - ✧ (green), 800 °C - [square] (red), 900 °C - * (dark blue), 1000 °C - Δ (light blue).

We believe that the reverse annealing characteristic is directly related to the shift of the maximum of radiation damage into the bulk from the depth of the primary defects, which corresponds to the maximum of the nuclear energy loss towards the projected range (Rp) of Ar ions. As the implantation temperature increases the mobility of point defects, lattice and impurity atoms also increases. Since the concentration of Ar atoms at Rp was relatively high (~ 0.4 at%) and its solubility is low, the stressed region with high Ar concentration may serve as a nucleation site for secondary defects. Thus it is conceivable that the increase of the damage in the temperature range between 500 °C and 700 °C is related to the build up of these secondary defects in the implanted layer.

A similar phenomenon was observed in GaN implanted at temperatures ranging from RT to 550 °C with 2.5×1015 cm−2 Mg+ at the dose rate up to 20 μA/cm2 Reference Wenzel, Liu and Rauschenbach[6]. The authors observed that backscattering yield increased with increasing irradiation temperature and suggested that this behavior is due to defects generated at high implantation temperatures. We believe that the same type of defects are responsible for the reverse annealing behavior for Ar+ and Mg+ irradiation of GaN, and that the different temperature range of this phenomenon is dictated by the magnitude of the dose rate, which was significantly higher in Reference Wenzel, Liu and Rauschenbach[6] than in our experiments. To check this, the dose rate was increased up to 4.5 μA/cm2 and the other implantation conditions were kept the same.

The integrated defect density, Id, in the bulk damage peak and the height of the surface peak, Hsp, as a function of the implantation temperature for two different dose rates are shown in Figure 3. The magnitude of Hsp decreases monotonically with temperature and there is little difference in the amount of disorder produced at different dose rates. However, the impact of the dose rate is apparent if one considers the disorder in the bulk damage peak. The shape of the Id(T) dependencies at both dose rates is very similar, but the retrograde behavior is shifted by ~100 °C towards lower temperatures at the higher dose rate value. We believe that there was extra heating of the samples during the implantations at 4.5 μA/cm2. This temperature rise was not recorded because the thermocouple was not exposed to the ion beam and was not attached to the sample surface but to the backside of the heater. Thus it is possible that the shift of the Id(T) dependence observed in Figure 3 resulted from the rise of actual sample temperature during the high dose rate irradiation.

Figure 3. The integrated damage in the bulk peak, Id, and the height of the surface peak, Hsp, as a function of the implantation temperature for two dose rates: 0.45 and 4.5μA/cm2.

Taking into account the temperature increase caused by high dose rate beam, one can explain the other discrepancies observed in Figure 3. For example, the decrease of the Hsp(Timp = RT) at the high dose rate results from annealing of damage, which in turn is caused by ion beam heating of the sample. The increase of the Hsp value at Timp = 1000 °C can also be explained by the ion-beam induced temperature increase. Studies on GaN decomposition in vacuum show that significant decomposition starts at T>1050 °C Reference Hong, Lee, Vartuli, Abernathy, MacKenzie, Donovan, Pearton and Zolper[11]. It has also been shown that nitrogen evaporates faster than gallium in this temperature range. Thus, the high dose rate beam raises the sample temperature into the regime where enhanced decomposition of GaN takes place. Therefore, the observed increase in the height of the surface peak and its width may be due to the effect of nitrogen loss during ion implantation. Examination of the sample surface using an optical microscope and an SEM shows that the surface is smooth and featureless. No Ga droplets were observed, probably because the thickness of the decomposed layer is insignificant for this effect to occur or because congruent evaporation takes place.

4. Conclusion

We have used RBS/C spectroscopy to comprehensively study the impact of implantation temperature on the accumulation of radiation defects in GaN during Ar+ implantation. Two disordered regions were identified in the damage depth distribution: the surface peak and the bulk damage peak. A pronounced difference between the damage build up behavior in these regions was found. The height of the surface peak representing the amount of the disorder in the Ga sublattice on the sample surface decreases with increasing implantation temperature and approaches the magnitude corresponding to an unimplanted sample. This behavior indicates that radiation damage on the sample surface is effectively removed by implantation at elevated temperatures. The amount of disorder in the bulk region demonstrates retrograde behavior with implantation temperature. We believe that the damaged region with high Ar concentration may serve as a nucleation site for a type of defect responsible for the reverse annealing feature. It has been shown that the temperature range wherein the reverse annealing regime occurs depends on the dose rate and its shift towards lower implantation temperatures results from extra heating of the sample during the high dose rate implantation. This result demonstrates the importance of careful substrate temperature measurements during high-temperature ion implantation.

ACKNOWLEDGMENTS

The authors would like acknowledge D. K. Hensley for the assistance during RBS/C analysis and Drs. S. P. Withrow and O. W. Holland for valuable discussions.

References

Papanicolau, N., Rao, M. V., Molnar, B., Tucker, J., Edwards, A., Holland, O. W., Ridgway, M. C., Nucl. Instrum. Methods B 148, 416 (1999).CrossRefGoogle Scholar
Pearton, S. J., Zolper, J. C., Shul, R. J., Ren, F., J. Appl. Phys. 86, 1 (1998).CrossRefGoogle Scholar
Kucheyev, S. O., Williams, J. S., Zou, J., Jagadish, C., Li, G., Nucl. Instrum. Methods B 178, 209 (2001).CrossRefGoogle Scholar
Liu, C., Wenzel, A., Volz, K., Rauschenbach, B., Nucl. Instrum. Methods B 148, 369 (1999).CrossRefGoogle Scholar
Parikh, N., Suvkhanov, A., Lioubtchenko, M., Carlson, E., Bremser, M., Bray, D., Davis, R., Hunn, J., Nucl. Instrum. Methods B 127/128, 463 (1997).CrossRefGoogle Scholar
Wenzel, A., Liu, C., Rauschenbach, B., Mater. Sci. Eng. B 59, 191 (1999).CrossRefGoogle Scholar
Eriksson, L., Davies, J. A., Johansson, N. G. E., Mayer, J. W., J. Appl. Phys. 40, 842 (1969).CrossRefGoogle Scholar
Picraux, S. T., Westmoreland, J. E., Mayer, J. W., Hart, R. R., Marsh, O. J., Appl. Phys. Lett. 14, 7 (1969).CrossRefGoogle Scholar
Hynes, T. E., Holland, O. W., Appl. Phys. Lett. 59, 452 (1991).CrossRefGoogle Scholar
Feldman, L. C., Mayer, J. M., Picraux, S. T., “Materials Analysis by Ion Channeling”, Academic Press, 117-135 (1982)Google Scholar
Hong, J, Lee, JW, Vartuli, CB, Abernathy, CR, MacKenzie, JD, Donovan, SM, Pearton, SJ, Zolper, JC, J. Vac. Sci. Technol. A 15, 797-801 (1997).CrossRefGoogle Scholar
Figure 0

Figure 1a. RBS/C spectra of GaN implanted with 150 keV Ar+ to the dose of 3×1015 cm−2 at different temperatures: RT - [square](red), 150 °C - ^ (green), 300 °C - Δ (dark blue), 500 °C - + (light blue). Black solid line corresponds to an unimplanted sample.

Figure 1

Figure 1b. RBS/C spectra of GaN implanted with 150 keV Ar+ to the dose of 3×1015 cm−2 at different temperatures: 500 °C - + (light blue), 600 °C - ∇ (dark blue), 700 °C - ✧ (green). Black solid line corresponds to an unimplanted sample.

Figure 2

Figure 1c. RBS/C spectra of GaN implanted with 150 keV Ar+ to the dose of 3×1015 cm−2 at different temperatures: 700 °C - ✧ (green;, 800 °C -[square] (red), 900 °C - * (dark blue), 1000 °C - Δ (light blue). Black solid line corresponds to an unimplanted sample.

Figure 3

Figure 2a. The depth distribution of damage, Nd(z), in GaN implanted with 150 keV Ar+ at different implantation temperatures obtained using equation 1: RT - [square] (red), 150 °C - o (green), 300 °C - Δ (dark blue), 500 °C - + (light blue).

Figure 4

Figure 2b. The depth distribution of damage, Nd(z), in GaN implanted with 150 keV Ar+ at different implantation temperatures obtained using equation 1: 500 °C - + (light blue), 600 °C - ∇ (dark blue), 700 °C - ✧ (green).

Figure 5

Figure 2c. The depth distribution of damage, Nd(z), in GaN implanted with 150 keV Ar+ at different implantation temperatures obtained using equation 1: 700 °C - ✧ (green), 800 °C - [square] (red), 900 °C - * (dark blue), 1000 °C - Δ (light blue).

Figure 6

Figure 3. The integrated damage in the bulk peak, Id, and the height of the surface peak, Hsp, as a function of the implantation temperature for two dose rates: 0.45 and 4.5μA/cm2.