Hostname: page-component-78c5997874-mlc7c Total loading time: 0 Render date: 2024-11-20T03:32:56.740Z Has data issue: false hasContentIssue false

Cannot ventilate, difficult to intubate

Published online by Cambridge University Press:  01 October 2007

D. B. Chethan*
Affiliation:
Department of AnaestheticsUniversity Hospital of WalesCardiff, UK
S. Rassam
Affiliation:
Department of AnaestheticsUniversity Hospital of WalesCardiff, UK
*
Correspondence to: Doddamanegowda Benkappa Chethan, Department of Anaesthetics, University Hospital of Wales, Cardiff CF14 4XW. E-mail: [email protected]; Tel: +44 2920 743107; Fax: +44 2920 745489

Abstract

Type
Correspondence
Copyright
Copyright © European Society of Anaesthesiology 2007

EDITOR:

We read with interest the letter by Slater and Bhatia [Reference Slater and Bhatia1] and would like to congratulate them on their successful management. We agree that the safest approach for their patient would have been an awake fibreoptic intubation. However, we would like to make a few comments.

From the history and picture, it is not clear whether the patient had a prosthesis fitted into the left orbital cavity. If so it could have deceived the airway assessment at preoperative visit. Difficult mask ventilation is, however, still appreciable as it appears to be impossible to achieve a seal with the face mask. In addition to this, a history of radiotherapy associated with limited mouth opening are ominous signs. Although the patient has had an anaesthetic for grommet insertion, it is possible that a spontaneously ventilating technique with a laryngeal mask airway (LMA) was used. If that was the case, the airway remains unchallenged after the radiotherapy following the initial craniofacial resection. We therefore believe that an awake fibreoptic intubation would have been a safer choice of securing the airway in the first place.

Once the situation of inability to ventilate the patient with a face mask was rescued by the LMA, the difficulty with intubation could have been dealt with one of the two options. Firstly, the trachea could have been blindly intubated via the size 5 LMA. Blind tracheal intubation via the laryngeal mask has been reported [Reference Heath and Allagain2] and it is recognized as one of the alternative approaches for tracheal intubation in the ASA difficult airway management algorithm [3]. However, the Difficult Airway Society guidelines draw attention to the fact that the classic LMA is not designed for this purpose and does not recommend blind intubation via the classic LMA. The other option is fibreoptic-assisted intubation through the LMA, which may have a higher chance of success [Reference Pandit, MacLachlan, Dravid and Popat4]. Secondly, an intubating laryngeal mask airway (ILMA) could have been used. Intubation could then have been blind via the ILMA or under direct vision using the fibreoptic scope. This technique has been used in patients in whom tracheal intubation using traditional methods had failed and also when other known or anticipated intubation difficulties were expected. Using an Aintree catheter with assisted fibreoptic intubation via these supraglottic devices is also reported and well recognized [Reference Higgs, Clark and Premraj5Reference Cook, Seller, Gupta, Thornton and O’Sullivan7]. By adopting any of these techniques the oxygenation would have been uninterrupted via a dedicated patent airway while allowing tracheal intubation. It would then have been possible to avoid the nasal route.

References

1.Slater, R, Bhatia, K. Cannot ventilate, difficult to intubate. Eur J Anaesthesiol 2007; 24: 377379.Google Scholar
2.Heath, ML, Allagain, J. Intubation through the laryngeal mask. A technique for unexpected difficult intubation. Anaesthesia 1991; 46: 545548.Google Scholar
3.Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology 2003; 98: 12691277.Google Scholar
4.Pandit, JJ, MacLachlan, K, Dravid, RM, Popat, MT. Comparison of times to achieve tracheal intubation with three techniques using the laryngeal or intubating laryngeal mask airway. Anaesthesia 2002; 57: 128132.Google Scholar
5.Higgs, A, Clark, E, Premraj, K. Low-skill fibreoptic intubation: use of the Aintree catheter with the classic LMA. Anaesthesia 2005; 60: 915920.Google Scholar
6.Cook, TM, Silsby, J, Simpson, TP. Airway rescue in acute upper airway obstruction using a ProSeal laryngeal mask airway and an Aintree catheter: a review of the ProSeal laryngeal mask airway in the management of the difficult airway. Anaesthesia 2005; 60: 11291136.CrossRefGoogle Scholar
7.Cook, TM, Seller, C, Gupta, K, Thornton, M, O’Sullivan, E. Non-conventional uses of the Aintree intubating catheter in management of the difficult airway. Anaesthesia 2007; 62: 169174.CrossRefGoogle ScholarPubMed