Impact of split X-jaw technique on target volume coverage and organ at risk sparing in prostate cancer: a comparative dosimetric study
Published online by Cambridge University Press: 13 May 2022
Abstract
The Varian Trilogy linear accelerator’s multi-leaf collimator moves on a carriage with a maximum leaf span of 15 cm. The traditional open and limited X-jaw technique of volumetric-modulated arc radiotherapy (VMAT) yields a relatively compromised dose distribution within the planning target volume (PTV) region. This study aimed to determine whether the split X-jaw planning technique for VMAT improves plan quality regarding target dose coverage and organs at risk (OAR) sparing for PTVs that require a field size of more than 15 cm in the X-jaw direction in prostate cancer patients.
Computed tomography data sets from 15 patients with prostate cancer were enrolled in the study. Only the PTVs requiring a field size larger than 18 cm in the X-jaw position were considered, and a dose of 4500 cGy in 25 fractions was prescribed. For each case, three separate treatment plans were generated: open, limited and split X-jaw planning techniques with similar planning objectives
The split X-jaw technique resulted in statistically significant superior coverage of PTV when compared with the open (P < 0·0001) and limited methods (P < 0·001). The split technique delivered a lower dose to the OARs, although statistical significance could not be achieved. D2% (cGy) was lowest for the PTV in the split technique (4684·8 ± 18·16) and highest for the open technique (4710 ± 18·75), P < 0·001.
The x-split jaw technique can replace the traditional open X-jaw practice of VMAT for PTVs requiring an X-jaw width of more than 15 cm in the Varian linear accelerator.