Introduction
In the head and neck (HnN) region, the proximity of organs at risk (OAR) to the tumour raises concerns about overdosage or underdosage in specific regions. Reference Ameri, Norouzi and Sourati1 During HnN cancer radiotherapy (RT), monitoring of possible changes during treatment is crucial for the accuracy and preservation of therapeutic outcomes. Reference Kam, Leung and Zee2,Reference Yang, Hu and Wang3 Tumour coverage and sparing of surrounding normal tissues leads to the best therapeutic outcome especially when high-precision RT techniques are implemented. Image-guided radiotherapy (IGRT) has significantly enhanced treatment precision by minimizing setup errors. Reference Waldon, Plank and Middleton4,Reference Lei and Wu5 Both offline and online IGRT correction strategies are applied to optimize treatment reproducibility, aiming to reduce the margins between the clinical target volume (CTV) and the planning target volume (PTV) as much as possible, while still achieving the desired clinical outcome. In clinical practice, patient imaging is used before and during treatment, to preserve the accuracy and efficacy of radiation treatment. Several studies noted that anatomical changes occur around the third or fourth week of treatment. Reference Bhandari, Patel and Gurjar6,Reference Hay, Paterson and McLoone7 Integration of anatomical and dosimetric variations into the treatment plan leads to the development of adaptive radiotherapy (ART). ART enhanced by IGRT focuses on identifying anatomical changes. This approach aims to address potential differences between the planned and the actual doses delivered to the tumour and the OARs. Reference Nuyttens, Robertson and Yan8–Reference Tsuji, Hwang and Weinberg10 Therefore, ART involves adjusting and implementing the treatment plan based on the tumour’s response and the anatomical changes in normal structures, which gains significant importance. Reference Srivastava, Sharma and Das11 In cases of significant anatomic variations occurring during treatment therapy, a new treatment plan based on the repeat-midpoint computed tomography (CT) scan needs to be implemented and compared with the initial treatment plan that is currently delivered to the patient. This includes a comparison between the initial dose calculation on the initial CT and the initial dose calculation transferred and calculated on the repeat CT, which is usually characterized as the hybrid plan. Reference Torchia and Velec12 The hypothesis, based on the analysis of registered images and structures, suggests that it should be feasible to recalculate the original treatment plan to accommodate the updated anatomy, thereby enabling the adaptation of the plan to these anatomical changes. Initiating ART for HnN cancer patients presents numerous benefits, particularly in preventing overexposure in critical organs, to enhance the quality of life in the future. The current study aims to present an implementation of ART for HnN patients performing a midpoint CT and utilizing a hybrid plan to evaluate the need for a replan. Volumetric and dosimetric deviations throughout treatment have been analysed. Additionally, anatomic and dosimetric trigger points which could reveal the need for a replan have also been presented.
Materials and Methods
This study included 31 consecutive patients with HnN cancer, aged 15 or older, diagnosed with various types of HnN cancer at stages I to IV and performance status 0 to 2 according to by American Joint Committee on Cancer and Eastern Cooperative Oncology Group criteria. Radiological diagnoses utilized multimodal scans (CT, MRI, and PET-CT) confirmed by a multidisciplinary team consensus. Patients received definitive or postoperative concomitant step-and-shoot IMRT over 30–33 fractions (6−7 weeks). The delineation of OARs and tumour volumes followed ICRU recommendations. 13–15 Gross tumour volume (GTV) was identified via observable tumours, suspicious lymph nodes and imaging techniques including CT, MRI, and FDG-PET. CTV was defined by anatomical limits, with the primary tumour’s CTV expanding from its GTV and involved lymph nodes’ CTV extending 3 mm from GTV into adjacent normal fat. The PTV was established by enlarging the CTV by 3 mm. Daily doses ranged from 2–2·12 Gy for the tumour bed, 1·8 Gy to microscopic tumour areas and high-risk lymph nodes and 1·64 Gy to the low-risk lymph nodes. Reference Lee, Harris and Garden16–21 Doses to the OARs have been compromised to meet the proposed dose constraints during treatment planning. Reference Marks, Yorke and Jackson22 Prescribed doses varied with 16 patients receiving 70 Gy and 14 receiving 66 Gy in the macroscopic disease. Most (25/31) received 60 Gy at high-risk lymph nodes. Additionally, 25 patients received 54 Gy, and 2 received 50 Gy at low-risk lymph nodes. PTV50 data were excluded due to insufficient number of patients (2/31). Changes in patient position or visible anatomical modifications were noted and evaluated.
The study involved two CT scans: CT1 acquired at the initial treatment plan (INT) and CT2 acquired at the midpoint. CT1 was registered onto CT2 using rigid registration. Contours set-1 from CT1 was transferred and registered to CT2. A hybrid plan (HYB) using dose calculation of the initial plan recalculated onto the anatomy of CT2 to assess the need for replanning. Contour set-2 was created on CT2, and an adaptive plan (ART) was generated for all patients. Dose and volume comparisons were then made to assess the efficacy of the adaptive plan versus the initial treatment plan.
Volumetric changes of targets and OARs between CT1 and CT2 were quantified in cubic centimetres (cc). Neck separation at C2 and T1 spinal vertebrae levels was measured in both CT1 and CT2 to assess changes that might occur. Reference Brouwer, Steenbakkers and Langendijk23 Dosimetric changes were evaluated using various plan quality metrics, including D95, D50, D2, Dmean, and Dmax. SPSS software (version 21·00, IBM) was used for statistical analysis. Descriptive statistics characterized variables, and the Kolmogorov–Smirnov test confirmed quantitative variables’ normality. Paired samples t-test assessed CT1 and CT2 volumes, and the impact of replanning. Significance was set at p < 0·05.
Results
Volumetric changes
Significant volumetric and anatomical changes were observed in tumour and parotid volumes during RT (Table 1, Figure 1). Specifically, among patients receiving 70 Gy to the tumour bed, 15/16 experienced a notable 15% reduction in PTV70 volume (p < 0·005). Regarding PTV66, although 11/14 patients receiving 60 Gy exhibited a 16% volume reduction, it did not reach statistical significance. Additionally, for PTV60, a reduction of 11% in volume was observed in 22/25 patients, and for PTV54, a 15% reduction in volume was measured in 20 out of 25 patients (p < 0·005).
A reported reduction in volume of 18% in the right parotid gland was observed in 27 patients. Likewise, a decrease of 20% was noted in the left parotid gland in 25 patients. Substantial reductions were noted in the lateral height at the C2 and T1 vertebral levels in all patients (p < 0.001), exhibiting an average decrease of 1.1 cm at C2 and 2.6 cm at T1, respectively. This decrease correlates with a 12% weight reduction observed at the time of the midpoint CT scan when compared to their baseline weight.
Dosimetric changes
The HYB plans exhibited inferior overall D95 coverage (Table 2) when compared to both INT and ART plans. In ART plans, the coverage of D95 in the PTV regions was maintained from the initial calculation. A noteworthy discrepancy between HYB and ART plans was observed, with statistically significant results identified only in the PTV54 (p < 0·005). The comparison between INT and HYB indicated an elevation in the dose of Dmax, with an increased D2 for the majority of patients when comparing HYB and INT. Specifically, a mean increase of 3·5% in the dose coverage of D2 was observed in 70% (22/31) of patients in PTV60 and PTV54. Minor alterations in D50 coverage were reported in hybrid plans compared to both initial and adaptive plans (p > 0·05).
Deviations in dose to OARs were also examined (Table 3). The study revealed increased parotid gland doses in HYB compared to ART plans, attributable to anatomical changes necessitating replanning. Specifically, 7/31 patients exhibited a 16·5% increase in the mean dose to the right parotid and a 13% increase in the left parotid, while others experienced a mean 13% decrease in both parotids with ART. Parotid doses demonstrated similarity between INT and ART plans, yielding non-significant results.
In HYB plans, excess spinal cord dose necessitated replanning, as the maximum dose exceeded dose limits in 5 out of 31 patients. While brainstem doses remained within limits in HYB plans, a 10% increase was reported in 20 out of 28 patients.
Discussion
The practice of ART in the management of HnN cancer illustrates a dynamic approach in radiation oncology that addresses the complexity and variability of tumour and normal tissue geometry throughout treatment. The inherent changes in patient anatomy, due to tumour’s response to therapy, weight loss or tissue oedema, necessitate a nuanced approach to ensure that the radiation dose delivered remains both effective and safe. The mid-treatment CT scan serves a pivotal role in this process, offering a contemporary image of the patient’s anatomy that can be used to evaluate and, if necessary, adjust the treatment plan to better tumour control, while sparing surrounding healthy tissues. Hybrid plans are utilized to evaluate the necessity of a replan before ART implementation. Reference Bhandari, Patel and Gurjar6,Reference Hay, Paterson and McLoone7,Reference Yang, Hu and Ding24 Yang et al. suggested that a hybrid plan might prompt an actual replan, especially for nasopharyngeal carcinoma cases. Reference Yang, Hu and Ding24 They also highlighted reductions in dose coverage and worse sparing in parotid glands, adding complexity to the discussion of the replanning frequency. Hybrid plans are proposed to be generated in the first half of treatment by overlaying the initial calculation on the repeat CT to assess the need for a replan. Volumetric and dosimetric deviations in dose coverage of tumour volumes and OARs were analysed as potential thresholds for guiding ART implementation.
HYB versus ART plan comparisons showed higher maximum doses in HYB plans with significant differences within the tumour and periphery. Tumour dose coverage revealed no significant differences between ART and HYB plans. Nevertheless, a decrease of D95 was measured in HYB plans, particularly in regressed tumour regions (PTV66, PTV60 and PTV54), failing the proposed D95 ≥ V95 criterion. The comparison between INT and HYB plans concluded with statistically significant results in the regions of PTV70, PTV66 and PTV54, triggering a need for a replan. In target regions including nodal tissues (PTV60 and PTV54), a mean decrease of 65% was measured, correlating with initial nodal volume deduction. Similarly, Bhandari et al.’s and Aly’s et al. results prompted adaptations due to a decrease in tumours’ D95 dose coverage. Reference Bhandari, Patel and Gurjar6,Reference Aly, Miller and Jameson25
Notable changes in the neck region, especially at C2 and T1 levels, were measured in CT scans. In the current study, patients with mean neck separation reduction over 1 cm, especially due to excessive weight loss, received a new immobilization mask, prompting a new CT scan and a replan, similar to the results of the study of Munich Radiation Oncology Department. Reference Capelle, Mackenzie and Field26 Patients experienced a mean weight loss of 12% midway through their RT course. Consequently, most patients exhibited volume reductions in PTV regions and OARs, especially in PTV66, PTV60 and PTV54, indicating substantial volume shrinkage at mid-treatment CT, with strong consideration for ART.
Replanning also enhanced parotid gland sparing and improved patients’ quality of life. Reference Fung, Wu and Teo27,Reference Lu, Ma and Chen28 In the current study, a mean 25% decrease in parotid volume (p < 0·005) was measured. This result complies with the neck separation decrease measured at the C2 vertebral spine level, where parotids are located. Significant differences were measured in the mean dose of the left parotid gland, with a 2·9 Gy increase in HYB versus INT plans and a 3·4 Gy increase in HYB versus ART plans, respectively (p < 0·05). However, right parotid gland comparisons did not yield significant results; however, a 2·2 Gy mean increase in hybrid plans was measured similar to the study of Lui et al. Reference Liu, Liang and Zhou29 An 85-patient study emphasized mid-treatment replanning due to significant shrinkage (> 31·1%) linked to weight loss and patient age. Reference Sanguineti, Ricchetti and Thomas30 The correlation between volume loss and increased mean dose to the parotids highlighted the importance of mid-treatment replanning when weight loss variations are more pronounced. Changes in the surrounding area due to factors like weight loss, tumour shrinkage and reduced neck separation affected the initial dose calculation of the spinal cord and the brainstem. Comparisons of HYB plans between INT and ART plans have not yielded statistically significant results, however, in the cases where the maximum dose exceeded the recommended constraints (spinal cord Dmax < 45–48Gy, brainstem Dmax < 59Gy), replanning became inevitable.
One limitation encountered during the implementation of ART primarily stemmed from the fact that CT image registrations were conducted only at the beginning and midpoint of the treatment course. Consequently, the dose delivered to the patient for each fraction was estimated rather than precisely measured. The necessity for replanning was justified by relying on dosimetric data from hybrid techniques as a conservative approach to assessment. Additionally, the current study involved various types of HnN cancer, where planned dose constraints and actual dose distributions were dependent on various factors. Nevertheless, establishing triggering points for replanning could serve as surrogates before the full implementation of ART.
Conclusions
ART has been proven to be necessary in cases where anatomical and dosimetric changes occur during radiotherapy of HnN cancer patients. A mid-treatment CT scan is suggested to provide information about the anatomy of the patient, along with a calculation of a hybrid plan to assess the need for a replan. Violation of the dose coverage of the tumour volume and excess in the maximum dose of critical organs can be used as surrogates for the implementation of ART. The criteria for implementing ART, based on dose coverage of the tumour volume and adherence to dose constraints for critical organs, underscore the precision required in radiotherapy. These parameters act as benchmarks to determine when the original treatment plan is no longer optimal due to anatomical and dosimetric deviations, thereby justifying a reevaluation and potential replan. Ultimately, the decision to employ ART in routine clinical practice hinges on the demonstration of clinical benefits.
Acknowledgements
None.
Financial support
None.
Competing interests
None.