Introduction
Electrical resistivity measurements have been a part of the Ross Ice Shelf Geophysical and Glaciological Survey (RIGGS) since its inception. A complete report on measurements at the RIGGS 1973–74 base camp (B.C.) (Fig. 1) during the first season has already been published (Reference BentleyBentley, 1977, hereinafter referred to as Paper I) and an oral paper has been presented on measurements the succeeding season (Reference BentleyBentley, 1976). The measurements in both cases were at stations where the temperature‒depth profile was not known. Drilling to a depth of 300 m in the ice shelf was carried out during the 1976–77 field season at station J9 (grid coordinates 7½° S., 1½° W.; Fig. 1) about 30 km down-stream from station B.C., as part of the Ross Ice Shelf Project program of drilling through the ice shelf. Although complete penetration of the 420 m-thick ice shelf was not obtained, temperature measurements made in the hole can be extrapolated with little error to the base of the ice. With the temperature known, it is possible to make a more direct determination of the dependence of resistivity on temperature, and thus on the activation energy, than was possible at previous sites.
Field Measurements
In November 1976, resistivity soundings were made at J9 along two perpendicular lines, “Profile 1” and “Profile 2”, Profile 2 having its center about one kilometer grid south-east of the center of Profile 1. Only Schlumberger measurements were carried out because previously we had experienced difficulties with dipole arrays. These difficulties were presumed to arise from the greater sensitivity of dipole arrays to inhomogeneities near to the surface (Paper I). The lines were extended to a maximum separation (a in Fig. 2) of 600 m along Profile 1 and 700 m along Profile 2.
The power source was a bank of dry cells of various sizes, producing a maximum of more than 3 kV. Most of the measurements, however, were made using either 1.2 kV or, for short spacings, 90 V. (The large jump in applied voltage was necessary for the current to fall within appropriate ammeter scales.) As before, copper rods were used for all spacings greater than a few meters. Contact resistance was generally reduced to less than one megohm per electrode by using salt water around the current electrodes. (The resistance was judged by measuring the initial current which flowed immediately after the high-voltage circuit had been switched on.) Potential differences were measured with a Keithley 600B electrometer having an input impedance of 1014 Ω. Several leakage measurements were made by disconnecting the wire to one of the current electrodes at the electrode and then switching on the high-voltage source. No test produced a current or potential difference significantly different from zero after the decay of the initial switching transient.
Data Reduction
Data were analyzed by the usual method of plotting the potential difference V versus the current I (see fig. 3 of Paper 1). Although the measurements at different separations showed a wide variation in scatter, each graph of V against I could be fitted either by a single straight line, or by two straight lines, one through the points with one direction of current flow, and the other through the points with reversed current. There were no indications of significant deviation from a zero intercept. Consequently, all the data were reduced, using least-square analysis, by fitting lines, forced through the origin, separately to the positive and negative polarizations for each measurement. The average of the two slopes thus obtained, called Ω+ and Ω− respectively, was taken as the resistance Ω for that measurement. (Conceptually it would be preferable to fit the “positive” and “negative” data with lines having equal and opposite intercepts, presumably corresponding to a background telluric potential. However, for the data of this paper, such a procedure does not produce apparent resistivities that are significantly different from those calculated by the simpler method employed here.) Apparent resistivities ρ a were then calculated from the mean resistances according to the formula
where a and b are the electrode spacings, defined in Figure 2.
The apparent resistivities measured on Profile 1 and Profile 2 are shown in Figures 3 and 4, respectively. Error bars represent
where σ+ and σ− are the standard deviations in the determinations of Ω+ and Ω−. The error bars indicate, therefore, only the scatter of the points around the “positive” and “negative” regression lines separately, with no contribution from the difference between Ω+ and Ω−; this reflects the assumption that any such difference has a physical cause that does not reverse with electrode polarity, and is therefore eliminated by taking the average of Ω+ and Ω−.The standard features of an apparent resistivity curve on an ice shelf, as described in Paper I, again appear clearly. The steep slope for a < 100 m reflects densification in the firn, the smaller slope at separations between about 150 m and 400 m is determined principally by the temperature effect in solid ice, and the increase in slope at larger distances results from conduction in the underlying sea-water. For comparison, a calculated apparent resistivity curve for a model that provided a good fit to the data in Paper I is also shown in each Figure. (This model took the activation energy E to be 1 eV (96 kJ mol−1) down to 40 m depth and 0.25 eV (24 kJ mol−1) at greater depths.)
It can be seen that smooth curves are quite well defined by the observations on both profiles. There is, however, one group of points at 500 to 600 m separation on Profile 2 (indicated by the enclosing parallelogram in Figure 4) that is significantly higher than the curve. The reason for the discrepancy is not known. These measurements were the first ones to be made on this profile, and were all made on the same day. The scatter of the observations is relatively large, but not nearly large enough to explain the high values of apparent resistivity. The leakage potential at a = 600 m was found to be 0.0±0.2 mV, compared with closed- circuit potentials of several volts. Even though there is no good a priori reason for ignoring these values, they have nevertheless been excluded from further consideration simply because of their disagreement with the remaining results. (A similar situation was found in Paper I, where the reason appeared to be associated with unusually small values of the potential-electrode separation. No such association occurs here.)
The apparent resistivity at a = 700 m was measured later on the same day as the discordant group, and yet it appears to fall, if anything, to a value which is too low rather than too high (Fig. 4). If the other values measured on that particular day are to be excluded, the one at 700 m should also be treated with caution, particularly as there is only one measurement at that distance. For that reason, the error bar at a = 700 m is indicated by a symbol which is drawn lighter than the others in Figure 4 and succeeding figures.
At each distance on each profile the weighted average apparent resistivity
has been calculated and plotted (Fig. 5). The weighted averages were evaluated using the technique of inverse variances. The standard-error estimates σ ρ were calculated according to the formulaThese standard errors are less than the radius of the points in Figure 5 (except as shown otherwise by the rectangular box at 700 m on Profile 2). Apparent resistivities from the two profiles are nearly in agreement, but those for Profile 2 are slightly less, on the average, than those for Profile 1. In order to remove this difference, so that the slope of the apparent resistivity curve, which is directly related to the activation energy, would be more clearly presented, a factor equal to the average ratio of observed apparent resistivities at the same distances on the two profiles for a ≥ 25 m was applied to Profile 2. Values from the two profiles then were averaged and standard errors calculated by Equation 1 so as to include the remaining differences between the two profiles. In the results (Fig. 6), apparent resistivities for a < 50 m have been removed because they are completely dependent upon conditions in the firn zone.
Analysis
Numerical modeling of the apparent resistivity was carried out in the same manner and using the same programs as in Paper 1. Temperatures were calculated according to the one-dimensional, steady-state model of Reference CraryCrary (1961). The resulting profile (Fig. 7) shows excellent agreement with the measured temperatures (personal communication from B. L. Hansen and J. Rand) when the bottom balance rate
is taken to be zero. Although, in reality, it is possible that because the ice shelf may not be in steady-state, or, because horizontal temperature gradients may be significant, any model that gives the correct temperature is satisfactory for a determination of the resistivity, so we limit further consideration to the caseThe variation of resistivity with density was assumed to follow the relation
where v is the ratio of firn density to ice density, and ρ f and ρ i are the resistivities of firn and ice respectively. This equation follows from Reference LooyengaLooyenga’s (1965) mixing equation, as discussed further in Paper I, Densities were taken from Reference LangwayLangway (1975; personal communication, 1977).
Two model curves have been calculated, both with E = 1.0 eV (96 kJ mol−1) in the upper ice. These two curves, matched at a = 200 m, appear to bracket the observations quite well (Fig. 6). The fit appears somewhat better for E = 0.15 eV than for E = 0.25 eV, particularly if less weight is placed on the rather uncertain value corresponding to 700 m separation.
For direct comparison, the values at station B.C., 30 km up-stream (Paper I), have been re-examined. Apparent resistivities from the two profiles there have been combined, in the same way as before (including the removal of the mean difference), with the results shown in Figure 8. Here again, the two model curves appear to bracket the observations.
Discussion
In considering the results of these measurements, it should be borne in mind that we are concerned primarily with ice-shelf depths between roughly 50 and 250 m, and thus with temperatures colder than −15° C. Conductivities at greater depths have little observable effect on the apparent resistivity measured at the surface, because the domination of current flowing in the very conductive sea-water (0.3 Ω m) beneath the ice shelf leads to low signal-to-noise ratios for V. At depths less than 50 m, density effects dominate all others.
Taken at face value, the results presented suggest that the activation energy for d.c. conduction in the Ross Ice Shelf at temperatures between −15 and −25° C lies between 0.15 and 0.25 eV (14-24 kJ mol−1), perhaps rather closer to the smaller figure than the larger. The larger figure is in good agreement with measurements made elsewhere on polar ice, particularly some recent measurements (Reference Glen and ParenGlen and Paren, 1975; Reference Fitzgerald and ParenFitzgerald and Paren. 1975: Reference Fitzgerald, Fitzgerald, Glen and ParenFitzgerald and others, 1977). However, our analysis does not take into account possible resistivity changes with depth in the solid ice due to factors other than temperature (e.g. impurity content, crystalline structure, grain size, or metamorphic history). Although the specific effect of these various factors on the resistivity is not known, resistivities certainly do vary from place to place in polar ice, as shown, for example, by the factor-of-two difference between the temperature-corrected resistivities at J9 and B.C. and those near Roosevelt Island and at Byrd Station (Paper I). From the plots of resistivity against depth corresponding to each model (Fig. 9) we can see that if the activation energy is actually 0.25 eV, then an apparent value of 0.15 eV would be produced by an increase in resistivity with increasing depth of about 50% from other sources.
The age of the ice at a depth of 250 m is on the order of 3000 years (Reference ThomasThomas. 1976). The length of time for the ice to move from the grounding line to the drill site is on the order of 1000 years, corresponding to a depth of about 100 m (Reference ThomasThomas, 1976). Most of the ice within the depth range of primary concern has, therefore, probably accumulated on the grounded West Antarctic ice sheet, whereas the upper part, of course, originated on the ice shelf itself.
Impurities, even if very dilute, could have a large effect on the resistivity. According to Reference Gross, Gross, Hayslip and HoyGross and others (1978), resistivity is proportional to [ NaCl concentration]−q . where q is about 0.4 or 0.5. This means that the 50% increase in resistivity with depth mentioned above could be brought about by reducing the impurity content by a factor of 2 to 3.
The evidence relating to impurity variation with depth at J9 is scanty, indirect, and partly contradictory. In a study of impurities in ice cores at Little America V, near the front of the Ross Ice Shelf. Reference Langway, Langway, Herron and CraginLangway and others (1974) found a cationic concentration decreasing with depth down to about 150 m; the variation between 50 and 150 m is almost an order of magnitude. On the other hand, Reference GowGow (1968) found a variation of only about a factor of two in the electrolytic conductivity of melted ice between 50 m and 150 m depth from the same core hole. Both Reference GowGow (1968) and Reference Langway, Langway, Herron and CraginLangway and others (1974) suggest that the ice below about 150 m at Little America originated on the grounded ice sheet of West Antarctica, and that the West Antarctic ice is purer than the ice accumulating on the ice shelf. If so, the same might be true at J9 resulting in a low apparent activation energy. On the other hand, it is difficult to extrapolate from Little America to J9 and the region up-stream, which is everywhere at least 500 km from the ocean. Certainly there is no firm reason to expect a two- or three-fold upstream decrease in impurity concentration, even though the snow mostly falls from cyclonic storms that have moved across the ice shelf into West Antarctica (personal communication from W . Schwerdtfeger, 1978). This point may be decided when chemical analyses on J9 ice cores are available.Footnote *
Differences in the metamorphic histories between ice samples can almost certainly produce large variations in conductivity. For example, it appears likely that the very low resistivity of cold polar ice results from its formation through a purely metamorphic process, that is, without melting (Reference Fitzgerald, Fitzgerald, Glen and ParenFitzgerald and others, 1977). Furthermore, it also appears likely that the basal ice coming from the West Antarctic ice streams, which presumably has had a very different metamorphic history from the ice nearer the surface, has an exceptionally high resistivity (Reference BentleyBentley, 1976; Shabtaie and Bentley, in press). However, since there is no reason to suspect any significant difference in the metamorphic history (other than different ages) along the ice-particle paths that correspond to depths of 50 and 250 m at J9. this factor can probably be discounted.
In contrast, significant variations in the grain-size and the crystalline fabric with depth in the ice shelf can be expected (e.g. Reference GowGow, 1968), but there is no reason to expect any marked change in the resistivity as a function of either of these variables. Reference Fitzgerald and ParenFitzgerald and Paren (1975) found no difference in the electrical behavior of ice samples from depths of 155 m and 1454 m at Byrd Station corresponding to a much larger age difference and much larger differences in grain-size and crystal fabric than would be expected between 50 and 250 m at J9. However, their measurements were made at frequencies of to kHz to 100 kHz and do not necessarily imply that there are no differences in d.c. conductivities.
These considerations, together with the very close agreement between the results at B.C. and J9, encourage us to believe that the activation energy, as determined by the resistivity method, does represent the true temperature effect on the ice in the ice shelf.
Conclusion
The new measurements at station J9 where the temperature has been measured, together with a re-examination of the values at station B.C. reported earlier (Paper I). suggest that the activation energy in the solid ice is rather less than 0.25 eV and perhaps as small as 0.15 eV. However, an alternative interpretation, that there is a reduction by a factor of two or three in the ionic impurity concentration between 50 and 250 m depth, cannot be entirely ruled out.
Acknowledgements
The author is especially grateful to L. L. Greischar and S. Shabtaie for their aid with field work at J9. D. G. Albert, J. W. Clough, J. F. Kirchner, H. Kohnen, and H. L. Pollak also provided helpful assistance. This research was supported by National Science Foundation grant DPP72-05802.