Published online by Cambridge University Press: 15 March 1999
In this paper, finite element method is used to compute inductance parameters of asquirrel cage induction machine. To take into account saturation effect, saturatedequivalent parameters are introduced, which depend on the instantaneous value of themagnetising current. For a balanced induction machine, the particular inductance behaviors allow straightforward flux expressions without any cross saturation effect.Moreover, these expressions are explained thanks to an extended analytical approachconsidering a magnetic saliency phenomenon by a second order air-gap permeance. Asimple way of transformation ratio and leakage inductance computation is also deduced.The numerical results show the compatibility between finite element approach and extended analytical Park's method. Besides, two operating points (at no load and for nominal speed) studied by the both methods give very closed results.