Hostname: page-component-cd9895bd7-mkpzs Total loading time: 0 Render date: 2024-12-25T16:23:41.248Z Has data issue: false hasContentIssue false

Synchrotron-based phase-contrast images of zebrafish and its anatomical structures

Published online by Cambridge University Press:  20 August 2014

Venkateswara Rao Donepudi*
Affiliation:
Department of Physics, Rajiv Gandhi University of Knowledge Technologies, A.P-IIIT, RK Valley, YSR (Dt), AP 516329, India
Bhaskaraiah Melumai
Affiliation:
Department of Physics, Rajiv Gandhi University of Knowledge Technologies, A.P-IIIT, RK Valley, YSR (Dt), AP 516329, India
Balasaidulu Thallapaka
Affiliation:
Department of Physics, Rajiv Gandhi University of Knowledge Technologies, A.P-IIIT, RK Valley, YSR (Dt), AP 516329, India
Konam Sandeep
Affiliation:
Department of Physics, Rajiv Gandhi University of Knowledge Technologies, A.P-IIIT, RK Valley, YSR (Dt), AP 516329, India
Roberto Cesareo
Affiliation:
Istituto di Matematica e Fisica, Università di Sassari, Via Vienna 2, Sassari 07100, Italy
Antonio Brunetti
Affiliation:
Istituto di Matematica e Fisica, Università di Sassari, Via Vienna 2, Sassari 07100, Italy
Zhong Zhong
Affiliation:
National Synchrotron Light Source, Brookhaven National Laboratory, Upton, NY 11973, USA
Takao Akatsuka
Affiliation:
Department of Bio-System Engineering, Faculty of Engineering, Yamagata University, Yonezawa-shi, Yamagata–992-8510, Japan
Tetsuya Yuasa
Affiliation:
Department of Bio-System Engineering, Faculty of Engineering, Yamagata University, Yonezawa-shi, Yamagata–992-8510, Japan
Tohoru Takeda
Affiliation:
Allied Health Science, Kitasato University 1-15-1 Kitasato, Sagamihara, Kanagawa 228-8555, Japan
Giovanni E. Gigante
Affiliation:
Dipartimento di Fisica, Università di Roma, La Sapienza, 00185 Roma, Italy
*
Get access

Abstract

Images of vertebrates (zebrafish and zebrafish eye) have been obtained by using an X-ray phase-contrast imaging technique, namely, synchrotron-based diffraction-enhanced imaging (SY-DEI) (or analyzer based imaging) and synchrotron-based diffraction imaging in tomography mode (SY-DEI-CT). Due to the limitations of the conventional radiographic imaging in visualizing the internal complex feature of the sample, we utilized the upgraded SY-DEI and SY-DEI-CT systems to acquire the images at 20, 30 and 40 keV, to observe the enhanced contrast. SY-DEI and SY-DEI-CT techniques exploits the refraction properties, and have great potential in studies of soft biological tissues, in particular for low (Z) elements, such as, C, H, O and N, which constitutes the soft tissue. Recently, these techniques are characterized by its extraordinary image quality, with improved contrast, by imaging invertebrates. We have chosen the vertebrate sample of zebrafish (Danio rerio), a model organism widely used in developmental biology and oncology. For biological imaging, these techniques are most sensitive to enhance the contrast. For the present study, images of the sample, in planar and tomography modes offer more clarity on the contrast enhancement of anatomical features of the eye, especially the nerve bundle, swim bladder, grills and some internal organs in gut with more visibility.

Type
Research Article
Copyright
© EDP Sciences, 2014

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

William Hendrich, H. III, Monte Westerfield, H., Leonard, I.Z., The Zebrafish: Biology, vol. 59 (Academic Press, USA, 1999), p. 274Google Scholar
Barot, B.A., Zon, L.I., Physiol. Genomics. 2, 49 (2000)
McMahon, C., Semina, E.V., Link, B.A., Comp. Biochem. Physiol. Part C: Toxicol. Pharmacol. 138, 343 (2004)
Goldsmith, P., Harris, W.A., Semin. Cell Dev. Biol. 14, 11 (2003)CrossRef
Glass, A.S., Dham, R., Ophthalmic Res. 36, 4 (2004)CrossRef
Dou, Y., Andersson-Lendahl, M., Arner, A., J. Gen. Physiol. 131, 445 (2008)CrossRef
Rao, D.V., Swapna, M., Cesareo, R., Brunetti, A., Zhong, Z., Akatsuka, T., Yuasa, T., Takeda, T., Gigante, G.E., Appl. Radiat. Isotopes 68, 1687 (2010)CrossRef
Takeda, T., Momose, M., Itai, Y., Wu, J., Hirano, K., Acad. Radiol. 2, 799 (1995)CrossRef
Momose, A., Takeda, T., Itai, Y., Rev. Sci. Instrum. 66, 1434 (1995)CrossRef
Momose, A., Takeda, T., Itai, Y., Hirano, K., Nat. Med. 2, 473 (1996)CrossRef
Takeda, T., Momose, M., Wu, J., Yu, Q., Zeniya, T., Thet-Thet-Lwin, , Yoneyama, Y., Itai, Y., Circulation 105, 1708 (2002)CrossRef
Takeda, T., Wu, J., Zeniya, T., Tsuchiya, Y., Thet-Thet-Lwin, , Rao, D.V., Yoneyama, Y., Momose, A., Hyodo, K., Aiyoshi, Y., Itai, Y., Medical Imaging Technology 20, 420 (2002)
Fitzgerald, R., Phys. Today 53, 23 (2000)CrossRef
Wilkins, S.W., Gurejev, T.E., Gao, D., Pogany, A., Stevenson, A.W., Nature 384, 335 (1996)CrossRef
Zhong, Z., Thomlinson, W., Chapman, D., Sayers, D., Nucl. Instrum. Methods A 450, 556 (2000)CrossRef
Zhong, Z., Chapman, D., Connor, D., Dilmanian, A., Gmur, N., Hasnah, M., Johnston, R., Kiss, M., Li, J., Synchrotron Radiat. News 15, 27 (2002)CrossRef