Hostname: page-component-78c5997874-t5tsf Total loading time: 0 Render date: 2024-11-06T11:04:20.734Z Has data issue: false hasContentIssue false

Emission signal enhancement and plasma diagnostics using collinear double pulse for laser-induced breakdown spectroscopy of aluminum alloys

Published online by Cambridge University Press:  08 March 2013

Dui-Xiong Sun
Affiliation:
Key laboratory of atomic and molecular physics and functional materials of Gansu Province, College of physics and Electronic engineering, NWNU, Lanzhou, 730070, P.R. China Joint Laboratory of Atomic and Molecular Physics, Northwest Normal University and Institute of Modern Physics of Chinese Academy of Sciences, Lanzhou 730070, P.R. China
Mao-Gen Su
Affiliation:
Key laboratory of atomic and molecular physics and functional materials of Gansu Province, College of physics and Electronic engineering, NWNU, Lanzhou, 730070, P.R. China Joint Laboratory of Atomic and Molecular Physics, Northwest Normal University and Institute of Modern Physics of Chinese Academy of Sciences, Lanzhou 730070, P.R. China
Chen-Zhong Dong*
Affiliation:
Key laboratory of atomic and molecular physics and functional materials of Gansu Province, College of physics and Electronic engineering, NWNU, Lanzhou, 730070, P.R. China Joint Laboratory of Atomic and Molecular Physics, Northwest Normal University and Institute of Modern Physics of Chinese Academy of Sciences, Lanzhou 730070, P.R. China
*
Get access

Abstract

A time and spatially resolved technique was used for the investigation of emission signal enhancement in collinear double-pulse LIBS. Two Q-switched Nd:YAG lasers at 1064 nm wavelength have been employed to produce laser-induced plasmas on aluminum-based alloys by single- (SP) and doublepulse (DP) LIBS. Time and spatial evolution of the plasma temperature and electron number density was investigated in these two experimental schemes. The enhancement of the emission line intensities was investigated, and a relation between the increases in intensity and excitation energy level was established. The results shows that the production of the second plasma by second laser pulse was important in DP experiment in collinear geometry.

Type
Research Article
Copyright
© EDP Sciences, 2013

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Majidi, V., Joseph, M.R., Crit. Rev. Anal. Chem. 23, 143 (1992)CrossRef
Rusak, D.A., Castle, B.C., Smith, B.W., Winefordner, J.D., Crit. Rev. Anal. Chem. 27, 257 (1997)CrossRef
Radziemski, L.J., Spectrochim. Acta B 57, 1109 (2002)CrossRef
Winefordner, J.D., Gornushkin, I.B., Correll, T., Gibb, E., Smith, B.W., Omenetto, N., J. Anal. At. Spectrom. 19, 1061 (2004)CrossRef
Reinhard, N., Volker, S., Ümit, A., Daniel, E., Christoph, G., Manuela, H., André, L., Joachim, M., Jens, V., Spectrochim. Acta B 63, 1159 (2008)
Bette, H., Noll, R., J. Phys. D: Appl. Phys. 37, 1281 (2004)CrossRef
Boué-Bigne, F., Appl. Spectrosc. 61, 333 (2007)CrossRef
Alvira, E.C., Rozzi, R.F., Bilmes, G.M., Appl. spectrosc. 64, 313 (2010)CrossRef
Singh, V.K., Rai, A.K., Lasers Med. Sci. 26, 307 (2011)CrossRef
Colao, F., Fantonia, R., Lazic, V., Paolini, A., Fabbri, F., Ori, G.G., Marinangeli, L., Baliva, A., Planet. Space Sci. 52, 117 (2004)CrossRef
Fichet, P., Tabarant, M., Salle, B., Gautier, C., Anal Bioanal. Chem. 385, 338 (2006)CrossRef
Piepmeier, E.H., Malmstadt, H.V., Anal. Chem. 41, 700 (1969)CrossRef
Scott, R.H., Strasheim, A., Spectrochim. Acta B 25, 311 (1970)CrossRef
Cremers, D.A., Radziemski, L.J., Loree, T.R., Appl. Spectrosc. 38, 721 (1984)CrossRef
Sattmann, R., Sturm, V., Noll, R., Appl. Phys. 28, 2181 (1995)
Uebbing, J., Brust, J., Sdorra, W., Leis, F., Niemax, K., Appl. Spectrosc. 45, 1419 (1991)CrossRef
St-Onge, L., Detalle, V., Sabsabi, M., Spectrochim. Acta B 57, 121 (2002)CrossRef
Babushok, V.I., Delucia, F.C., Gottfried, J.L., Munson, C.A., Miziolek, A.W., Spectrochim. Acta B 61, 999 (2006)CrossRef
Corsi, M., Cristoforetti, G., Giuffrida, M., Hidalgo, M., Legnaioli, S., Palleschi, V., Salvetti, A., Tognoni, E., Vallebona, C., Spectrochim. Acta B. 59, 723 (2004)CrossRef
Cristoforetti, G., Legnajoli, S., Palleschi, V., Salvetti, A., Tognoni, E., Spectrochim. Acta B 59, 1907 (2004)CrossRef
Noll, R., Sattmann, R., Sturm, V., Winkelmann, S., J. Anal. At. Spectrom. 19, 419 (2004)CrossRef
Rai, V.N., Yueh, F.Y., Singh, J.P., Appl. Optics. 47, G21 (2008)CrossRef
Lee, D.H., Han, S.C., Kim, T.H., Yun, J., Anal. Chem. 83, 9456 (2011)CrossRef
Abdellatif, G., Imam, H., Spectrochim. Acta B 57, 1155 (2002)CrossRef
Yalcin, S., Crosley, D.R., Smith, G.P., Faris, G.W., Appl. Phys. B 68, 121 (1999)
Aguilera, J.A., Aragón, C., Spectrochim. Acta B 59, 1861 (2004)CrossRef
Beldjilali, S., Yip, W.L., Hermann, J., Hamed, T.B., Anal. Bioanal. Chem. 400, 2173 (2011)CrossRef
Giacomo, A.D., Dell’Aglio, M., Bruno, D., Gaudiuso, R., Pascale, O.D., Spectrochim. Acta B 63, 805 (2008)CrossRef
Gautier, C., Fichet, P., Menut, D., Lacour, J.L., Hermite, D.L., Dubessy, J., Spectrochim. Acta B 60, 265 (2005)CrossRef
Mao, X.L., Zeng, X.Z., Wen, S.B., Russo, R.E., Spectrochim. Acta B 60, 960 (2005)CrossRef