Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

This paper describes a Lageos laser ranging station design based on single photoelectron detection which could be used to monitor polar motion at all periods, and short-period UT1 variations with high accuracy and at moderately low cost. No comparison has been made with the costs of long baseline radio interferometry (LBI) stations, since the establishment and operation of basic international networks using both approaches seems scientifically well justified. Both LBI and lunar laser ranging results will determine intermediate and long-period UT1 variations and nutation. The LAGEOS laser ranging station design suggested here is similar to the design used in the high-mobility LAGEOS ranging station now being constructed by the University of Texas. It has been shown that 30 cm diameter transmit/receive optics with 10 arc second pointing accuracy and 50 milliwatt average laser power output are usually sufficient to give 70 signal counts in a three minute averaging time, even at 20° elevation angle. Lasers having the desired power at 530 nm wavelength with 10 pps repetition rate and 3 ns pulse length are now reported to be commercially available at moderate cost. The resulting range accuracy for normal points corresponding to the three minute averaging time is three cm, including allowances for absolute calibration of the system, atmospheric refraction correction uncertainties, and Earth tide uncertainties. Much of the pulse-timing electronics needed is commercially available, and many time and latitude stations already have good epoch determination systems. The ten arc second pointing requirement for a 30 cm diameter beam seems considerably easier to meet than the optical requirements for classical observing techniques. A simple beam director with flat mirrors appears quite feasible, with inexpensive encoders on each axis for minicomputer control if desired. A number of special features of the University of Texas high-mobility station would not be needed for a fixed station.

Type
Part V: Satellite Laser Ranging
Copyright
Copyright © Reidel 1979