Hostname: page-component-cd9895bd7-gvvz8 Total loading time: 0 Render date: 2024-12-23T19:32:44.108Z Has data issue: false hasContentIssue false

Control of flexible knee joint exoskeleton robot based on dynamic model

Published online by Cambridge University Press:  03 February 2022

Biao Liu
Affiliation:
Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou, 510640, China
YouWei Liu
Affiliation:
Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou, 510640, China
Zikang Zhou
Affiliation:
Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou, 510640, China
Longhan Xie*
Affiliation:
Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou, 510640, China
*
*Corresponding author. E-mail: [email protected]

Summary

The knee joint plays a significant role in ground clearness, which is a crucial subtask of normal walking and avoiding falls. While post-stroke survivors are often faced with muscle weakness during walking, which leads to inadequate knee flexion. The lack of ground clearance caused by inadequate knee flexion will severely impede walking, increase metabolic exertion, and increase the risk of falls. A compliant exoskeleton robot possesses more favorable edges than other rigid ones in lightweight, safety, sense of comfort, and so on. We developed a new type of soft exoskeleton robot to assist the knee joint to achieve desired movements with Bowden cable transmitting force and torque. With the agonist–antagonist driving method, like a group of muscles working, we have explored dual-motors structure to realize the knee flexion function. It has built a standard dynamic model to analyze stability and realize the control law. We have conducted simulation and prototype experiments to verify the feasibility and usefulness of our method. The results show that the device can compensate for the lack of the knee joint driving force and realize the reference movement. Finally, we concluded that our method is a desirable way, and the scheme could improve the knee flexion ability and clearing ground.

Type
Research Article
Copyright
© The Author(s), 2022. Published by Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Zhou, M., Wang, H., Zeng, X., Yin, P., Zhu, J., Chen, W., Li, X., Wang, L., Wang, L. and Liu, Y. J. T. L., “Mortality, morbidity, and risk factors in China and its provinces, 1990–2017: a systematic analysis for the Global Burden of Disease Study 2017,” The Lancet. 394(10204), 11451158 (2019)..CrossRefGoogle ScholarPubMed
Sulzer, J. S., Roiz, R. A., Peshkin, M. A. and Patton, J. L., “A highly backdrivable, lightweight knee actuator for investigating gait in stroke,” IEEE Trans. Rob. 25(3), 539548 (2009).CrossRefGoogle ScholarPubMed
Park, D., In, H., Lee, H., Lee, S., Koo, I., Kang, B. B., Park, K., Chang, W. S. and Cho, K.-J., “Preliminary study for a soft wearable knee extensor to assist physically weak people,” 2014 11th International Conference on Ubiquitous Robots and Ambient Intelligence (URAI).pp. 136–137.CrossRefGoogle Scholar
Schmidt, K., Duarte, J. E., Grimmer, M., Sancho-Puchades, A., Wei, H., Easthope, C. S. and Riener, R., “The myosuit:Bi-articular anti-gravity exosuit that reduces hip extensor activity in sitting transfers,”Front. Neurorob. 11, 57 (2017).CrossRefGoogle ScholarPubMed
Collins, S. H., Wiggin, M. B. and Sawicki, G. S., “Reducing the energy cost of human walking using an unpowered exoskeleton,” Nature. 522(7555), 212215 (2015).CrossRefGoogle ScholarPubMed
Phee, S. J., Low, S. C., Dario, P. and Menciassi, A., “Tendon sheath analysis for estimation of distal end force and elongation for sensorless distal end,” Robotica. 28(7), 10731082 (2010).CrossRefGoogle Scholar
Cheng, S. S., Wang, X. and Desai, J. P., “Design and analysis of a remotely-actuated cable-driven neurosurgical robot.” 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS). IEEE.pp. 1685–1690.CrossRefGoogle Scholar
Dinh, B. K., Xiloyannis, M., Antuvan, C. W., Cappello, L. and Masia, L., “Hierarchical cascade controller for assistance modulation in a soft wearable arm exoskeleton,” IEEE Robot. Autom. Lett. 2(3), 17861793 (2017).CrossRefGoogle Scholar
Kuan, J.-Y., Pasch, K. A. and Herr, H. M., “A high-performance cable-drive module for the development of wearable devices,” IEEE/ASME Trans. Mechatron. 23(3), 12381248 (2018).CrossRefGoogle Scholar
Awad, L. N., Bae, J., O’donnell, K., De Rossi, S. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G. and Ellis, T. D., “A soft robotic exosuit improves walking in patients after stroke,” Sci. Transl. Med. 9(400), eaai9084 (2017).CrossRefGoogle ScholarPubMed
Malcolm, P., Lee, S., Crea, S., Siviy, C., Saucedo, F., Galiana, I., Panizzolo, F. A., Holt, K. G. and Walsh, C. J., “Varying negative work assistance at the ankle with a soft exosuit during loaded walking,” J. Neuroeng. Rehabil. 14(1), 62 (2017).CrossRefGoogle ScholarPubMed
Ding, Y., Galiana, I., Siviy, C., Panizzolo, F. A. and Walsh, C., “IMU-based iterative control for hip extension assistance with a soft exosuit.” 2016 IEEE International Conference on Robotics and Automation (ICRA). IEEE.pp. 3501–3508.CrossRefGoogle Scholar
Senturk, Y. M., and Patoglu, V., “MRI-VisAct: a Bowden-cable-driven MRI-compatible series viscoelastic actuator,” Trans. Inst. Meas. Control. 40(8), 24402453 (2018).CrossRefGoogle Scholar
Gaponov, I. and Ryu, J.-H., “Twisted String Actuators: Life Cycle, Twisting inside Bowden Cables, and Passive Return Mechanisms,” Stroke. 10, 20 (2016).Google Scholar
Thompson, N., Sinha, A. and Krishnan, G., “Characterizing architectures of soft pneumatic actuators for a cable-driven shoulder exoskeleton.” 2019 International Conference on Robotics and Automation (ICRA). pp. 570–576.CrossRefGoogle Scholar
Ding, Y., Kim, M., Kuindersma, S. and Walsh, C. J., “Human-in-the-loop optimization of hip assistance with a soft exosuit during walking,” Sci. Robot. 3(15), eaar5438 (2018).CrossRefGoogle ScholarPubMed
Zhang, J., Fiers, P., Witte, K. A., Jackson, R. W., Poggensee, K. L., Atkeson, C. G. and Collins, S. H., “Human-in-the-loop optimization of exoskeleton assistance during walking,” Science. 356(6344), 12801284 (2017).CrossRefGoogle ScholarPubMed
Ding, Y., Panizzolo, F. A., Siviy, C., Malcolm, P., Galiana, I., Holt, K. G. and Walsh, C. J., “Effect of timing of hip extension assistance during loaded walking with a soft exosuit,” J. Neuroeng. Rehabil. 13(1), 87 (2016).CrossRefGoogle ScholarPubMed
Panizzolo, F. A., Galiana, I., Asbeck, A. T., Siviy, C., Schmidt, K., Holt, K. G. and Walsh, C. J., “A biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking,” J. Neuroeng. Rehabil. 13(1), 43 (2016).CrossRefGoogle ScholarPubMed
Quinlivan, B., Lee, S., Malcolm, P., Rossi, D., Grimmer, M., Siviy, C., Karavas, N., Wagner, D., Asbeck, A. and Galiana, I., “Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit,” Sci. Robot. 2(2), 110 (2017).CrossRefGoogle ScholarPubMed
Jeong, U. and Cho, K.-J., “A feasibility study on tension control of Bowden-cable based on a dual-wire scheme.” 2017 IEEE international conference on robotics and automation (ICRA). IEEE. pp. 3690–3695.CrossRefGoogle Scholar
Rodríguez-León, J. F., Chaparro-Rico, B. D., Russo, M. and Cafolla, D., “An Autotuning Cable-Driven Device for Home Rehabilitation,” J. Healthcare Eng. 2021 (2021).CrossRefGoogle ScholarPubMed
Hamill, J. and Knutzen, K. M., Biomechanical basis of human movement (Lippincott Williams & Wilkins, 2006).Google Scholar
Musić, J., Kamnik, R., Zanchi, V. and Munih, M., “Human body model based inertial measurement of sit-to-stand motion kinematics,”  WSEAS Trans. Syst7(3), 156164 (2008).Google Scholar
Yang, C., Huang, Q., Ye, Z. and Han, J., “Dynamic modeling of spatial 6-DOF parallel robots using Kane method for control purposes.” 2010 Second International Conference on Intelligent Human-Machine Systems and Cybernetics. pp. 180–183.CrossRefGoogle Scholar
Vundavilli, P. R. and Pratihar, D. K., “Dynamically Balanced Ascending Gait Generation of a Biped Robot Negotiating Staircase.” 2008 IEEE Region 10 and the Third international Conference on Industrial and Information Systems. IEEE.pp. 1–6.Google Scholar
Winter, D. A., Biomechanics and motor control of human movement (John Wiley & Sons, 2009).CrossRefGoogle Scholar
Hong, Y. and Bartlett, R., Routledge handbook of biomechanics and human movement science (Routledge, 2008).CrossRefGoogle Scholar
Robertson, G. E., Caldwell, G. E., Hamill, J., Kamen, G. and Whittlesey, S., Research methods in biomechanics (Human kinetics, 2013).Google Scholar
Kaneko, M., Yamashita, T. and Tanie, K., “Basic considerations on transmission characteristics for tendon drive robots.”Fifth International Conference on Advanced Robotics' Robots in Unstructured Environments. IEEE. pp. 827–832.Google Scholar
Wang, J., Li, X., Huang, T.-H., Yu, S., Li, Y., Chen, T., Carriero, A., Oh-Park, M., Su, H. J. I. R. and Letters, A., “Comfort-centered design of a lightweight and backdrivable knee exoskeleton,” IEEE Robotics and Automation Letters. 3(4), 42654272 (2018).CrossRefGoogle Scholar
Zhang, F., Yang, L. and Fu, Y., “Design of a novel elastic torque sensor for hand injuries rehabilitation based on bowden cable,” IEEE Trans. Instrum. Meas. 68(9), 31843192 (2018).CrossRefGoogle Scholar
Yin, M., Wu, H., Xu, Z., Han, W. and Zhao, Z., “Compliant control of single tendon-sheath actuators applied to a robotic manipulator,” IEEE Access. 8, 3736137371 (2020).CrossRefGoogle Scholar
Chaparro-Rico, B. D., Cafolla, D., Tortola, P. and Galardi, G. J. A. S., “Assessing Stiffness, Joint Torque and ROM for Paretic and Non-Paretic Lower Limbs during the Subacute Phase of Stroke Using Lokomat Tools,” Appl. Sci. 10(18), 6168 (2020).CrossRefGoogle Scholar
Chaparro-Rico, B. D. and Cafolla, D. J. A. S., “Test-retest, inter-rater and intra-rater reliability for spatiotemporal gait parameters using SANE (an eaSy gAit aNalysis systEm) as measuring instrument,”  Appl. Sci. 10(17), 5781 (2020).CrossRefGoogle Scholar