Hostname: page-component-78c5997874-4rdpn Total loading time: 0 Render date: 2024-11-20T02:43:23.803Z Has data issue: false hasContentIssue false

Shielding calculation for the Proton-Therapy-Center in Prague, Czech Republic

Published online by Cambridge University Press:  28 September 2012

Get access

Abstract

The study of radiation fields around the cyclotron roomwas carried out for the Proton-Therapy-Center in Prague (Czech Republic).The 230 MeV proton cyclotron will be installed there as well asadditional components located along the beampath. The ambient doseswere computed by taking into account 3 major sources of secondaryradiation (neutron and photon) – the cyclotron, energy degraderand its collimator. The fluxes of neutrons/photons produced by protonswere computed using Monte Carlo code MCNPXTM 2.5.0. Energyand angular distributions were computed for various targets and protonbeam energies. Different physical models of high-energy proton interactionswere studied as well. The annual charge at the cyclotron exit wasbased on the “patient model” (distribution of treatment type) establishedfor a similar therapy center in Essen (Germany). Calculated datawere used as an approximation of the radiation field of the most significantsources of radiation (graphite degrader, tantalum collimator). Fluence-to-doseconversion factors from ICRP-74 were used for the annual dose equivalentevaluation. With these results, the shielding analysis in the Therapy-Centerwas performed in the context of the current legislation requirements.

Type
Research Article
Copyright
© EDP Sciences, 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

ICRP Publication 74 (1996) Conversion coefficient for use in radiological protection against radiation, Ann. ICRP 26 (3-4).
NCRP (2005) Report No. 144, Radiation protection for particle accelerator facilities, National Council on Radiation protection and Measurements, issued December 31, 2003, revised January 7, 2005, Radiat. Prot. Dosim. 113 (4), 456-457.
Newhauser, W.D. et al. (2002) Neutron shielding verification measurements and simulations for a 235-MeV proton therapy center, Nucl. Instrum. Meth. Phys. Res. A 476, 8084.Google Scholar
Pelowitz D.B. (2005) MCNPXTM user’s manual, version 2.5.0.
Stichelbaut F. (2007) Radiation Sources in Praha Proton Therapy Center, December 18, 2007, presentation.
Stichelbaut F. (2008) Shielding Calculations for PT Center in Praha, Czech Republic, April 9, 2008, presentation.