Hostname: page-component-78c5997874-94fs2 Total loading time: 0 Render date: 2024-11-20T01:45:27.152Z Has data issue: false hasContentIssue false

Progress at the Seoul National University AMS Facility

Published online by Cambridge University Press:  18 July 2016

J C Kim*
Affiliation:
Department of Physics, Seoul National University, Seoul 151-742, Korea Inter-University Center for Natural Science Research Facility, Seoul National University, Seoul, Korea
J H Park
Affiliation:
Department of Physics, Seoul National University, Seoul 151-742, Korea
I C Kim
Affiliation:
Department of Physics, Seoul National University, Seoul 151-742, Korea
C Lee
Affiliation:
Inter-University Center for Natural Science Research Facility, Seoul National University, Seoul, Korea
M K Cheoun
Affiliation:
Inter-University Center for Natural Science Research Facility, Seoul National University, Seoul, Korea
J Kang
Affiliation:
Inter-University Center for Natural Science Research Facility, Seoul National University, Seoul, Korea
Y M Song
Affiliation:
Inter-University Center for Natural Science Research Facility, Seoul National University, Seoul, Korea
*
Corresponding author. Email: [email protected].
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

The accelerator mass spectrometry facility at the Seoul National University (SNU-AMS) was completed in December 1998 and a report was presented at the Vienna AMS conference in September 1999. At the conference, we described the basic components of our accelerator system and reported the results of the performance test. Since then, extensive testing of the accuracy and reproducibility of the system has been carried out, and about 200 unknown samples have been measured so far. We obtained a precision of 4‰ for modern samples, and an accuracy of approximately 40 yr was demonstrated by analyzing samples that were previously dated with a conventional technique and by other AMS laboratories. We present these results here, together with detailed descriptions of our data-taking and analysis procedures.

Type
I. Becoming Better
Copyright
Copyright © The Arizona Board of Regents on behalf of the University of Arizona 

References

Aerts-Bijma, ATh, Meijer, HAJ, van der Plicht, J 1997. AMS sample handling in Groningen. Nuclear Instruments and Methods in Physics Research B123:221–5.Google Scholar
Gottdang, A, Mous, DJW, van der Plicht, J. 1995. The HVEE 14C system at Groningen. Radiocarbon 37(2): 649–56.Google Scholar
Kim, JC, Lee, CH, Kim, IC, Park, JH, Kang, J, Cheoun, MK, Kim, YD, Moon, CB. 2000. A new AMS facility in Korea. Nuclear Instruments and Methods B172:13–7.Google Scholar
Mook, WG, van der Plicht, J. 1999. Reporting 14C activities and concentration. Radiocarbon 41(3): 227–39.Google Scholar
Morgenroth, G, Kerscher, H, Kretschmer, W, Klein, M, Rechel, M, Wrzosok, I. 2000. Improved sample preparation techniques at the Erlangen AMS-facility. Nuclear Instruments and Methods in Physics Research B172: 416–23.Google Scholar
Nadeau, MJ, Schleicher, M, Grootes, PM, Erleneuser, H, Gottdang, A, Mous, DJW, Sarnthein, JM, Willkomm, H. 1997. The Leibniz-Labor AMS facility at the Christian-Albrecht-University, Kiel, Germany. Nuclear Instruments and Methods in Physics Research B123:2230.Google Scholar
Olsson, IU. 1980. 14C in extractives from wood. Radiocarbon 22(2):515–24.Google Scholar
Purser, KH, Smick, TH, Litherland, AE, Beukens, RP, Kieser, WE, Kilius, LR. 1988. A third generation 14C accelerator mass spectrometry. Nuclear Instruments and Methods in Physics Research B135:284–91.Google Scholar
Rozanski, K Stichler, W, Gonfiantini, R, Scott, EM, Beukens, RP, Kromer, B, van der Plicht, J. 1990. The IAEA 14C Intercomparison Exercise 1990. Radiocarbon 34(3):506–19.Google Scholar
Stuiver, M, Polach, HA. 1977. Discussion: reporting of 14C data. Radiocarbon 19(3):355–63.Google Scholar
Stuiver, M. 1983. Buisness meeting. Radiocarbon 25(2): 793–5.Google Scholar
Vogel, JS, Nelson, DE, Southon, JR. 1987. 14C background levels in an accelerator mass spectrometry system. Radiocarbon 29(3):323–33.Google Scholar