Hostname: page-component-586b7cd67f-t7czq Total loading time: 0 Render date: 2024-11-25T10:37:47.917Z Has data issue: false hasContentIssue false

Lithium Contamination in AMS Measurements of 14C

Published online by Cambridge University Press:  18 July 2016

D. H. Loyd*
Affiliation:
Center for Accelerator Mass Spectrometry, University of California
J. S. Vogel
Affiliation:
Lawrence Livermore National Laboratory, Livermore, California 94550 USA
Susan Trumbore
Affiliation:
Lawrence Livermore National Laboratory, Livermore, California 94550 USA
*
1Permanent address: Department of Physics, Angelo State University, San Angelo, Texas 76909 USA
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

High count rates of lithium ions in an AMS measurement system for 14C were traced to the lithium content in the quartz tubes used in the graphitization of the samples. The lithium contamination was nearly eliminated by the use of borosilicate glass reaction tubes at a lower reaction temperature. The ion beam current and the measurement precision of the isotope ratio were not affected.

Type
Articles
Copyright
Copyright © The American Journal of Science 

References

Eitel, W. 1966 Silicate Science 4. New York, Academic Press: 11 p.Google Scholar
Hennig, G. R. 1959 Interstitial compounds of graphite. Progress in Inorganic Chemistry 1: 125205.Google Scholar
Kromer, B., Pfleiderer, C., Schlosser, P., Levin, I. and Münnich, K. O. 1987 AMS 14C measurement of small volume oceanic water samples: Experimental procedure and comparison with low-level counting technique. In Gove, H. E., Litherland, A. E. and Elmore, D., eds., Proceedings of the 4th International Symposium on Accelerator Mass Spectrometry. Nuclear Instruments and Methods B29: 302305.Google Scholar
Nelson, D. E., Korteling, R. G. and Stott, W. R. 1977 Carbon-14: Direct detection at natural concentrations. Science 198: 507508.Google Scholar
Nordberg, M. E. 1944 Properties of some Vycor-brand glasses. Journal of the American Ceramic Society 27(10): 299305.CrossRefGoogle Scholar
Vogel, J. S., Nelson, D. E. and Southon, J. R. 1987 14C background levels in an accelerator mass spectrometry system. Radiocarbon 29(3): 323333.Google Scholar
Vogel, J. S., Southon, J. R. and Nelson, D. E. 1987 Catalyst and binder effects in the use of filamentous graphite for AMS. In Gove, H. E., Litherland, A. E. and Elmore, D., eds, Proceedings of the 4th International Symposium on Accelerator Mass Spectrometry. Nuclear Instruments and Methods B29: 5056.CrossRefGoogle Scholar