Hostname: page-component-586b7cd67f-gb8f7 Total loading time: 0 Render date: 2024-11-22T17:21:30.319Z Has data issue: false hasContentIssue false

Testing of the LSST’s photometric calibration strategy at the CTIO 0.9 meter telescope

Published online by Cambridge University Press:  03 March 2020

Michael W. Coughlin
Affiliation:
Division of Physics, Math, and Astronomy, California Institute of Technology, Pasadena, CA91125, USA, email: [email protected]
Susana Deustua
Affiliation:
Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD21218, USA
Augustin Guyonnet
Affiliation:
Department of Physics, Harvard University, Cambridge, MA02138, USA
Nicholas Mondrik
Affiliation:
Department of Physics, Harvard University, Cambridge, MA02138, USA LSSTC Data Science Fellow
Joseph P. Rice
Affiliation:
National Institute of Standards and Technology (NIST), 100 Bureau Drive, Gaithersburg MD20899
Christopher W. Stubbs
Affiliation:
Department of Physics, Harvard University, Cambridge, MA02138, USA Department of Astronomy, Harvard University, CambridgeMA02138, USA
John T. Woodward
Affiliation:
National Institute of Standards and Technology (NIST), 100 Bureau Drive, Gaithersburg MD20899
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

The calibration hardware system of the Large Synoptic Survey Telescope (LSST) is designed to measure two quantities: a telescope’s instrumental response and atmospheric transmission, both as a function of wavelength. First of all, a “collimated beam projector” is designed to measure the instrumental response function by projecting monochromatic light through a mask and a collimating optic onto the telescope. During the measurement, the light level is monitored with a NIST-traceable photodiode. This method does not suffer from stray light effects or the reflections (known as ghosting) present when using a flat-field screen illumination, which has a systematic source of uncertainty from uncontrolled reflections. It allows for an independent measurement of the throughput of the telescope’s optical train as well as each filter’s transmission as a function of position on the primary mirror. Second, CALSPEC stars can be used as calibrated light sources to illuminate the atmosphere and measure its transmission. To measure the atmosphere’s transfer function, we use the telescope’s imager with a Ronchi grating in place of a filter to configure it as a low resolution slitless spectrograph. In this paper, we describe this calibration strategy, focusing on results from a prototype system at the Cerro Tololo Inter-American Observatory (CTIO) 0.9 meter telescope. We compare the instrumental throughput measurements to nominal values measured using a laboratory spectrophotometer, and we describe measurements of the atmosphere made via CALSPEC standard stars during the same run.

Type
Contributed Papers
Copyright
© International Astronomical Union 2020