Hostname: page-component-586b7cd67f-2brh9 Total loading time: 0 Render date: 2024-11-23T07:45:16.926Z Has data issue: false hasContentIssue false

Coronal Multi-channel Polarimeter at the Lomnicky Peak Observatory

Published online by Cambridge University Press:  06 January 2014

P. Schwartz
Affiliation:
Astronomical Institute of Slovak Academy of Sciences, 05960 Tatranská Lomnica, Slovakia email: [email protected] Astronomical Institute, Academy of Sciences of the Czech Republic, 25165 Ondřejov, Czech Republic
J. Ambroz
Affiliation:
Astronomical Institute of Slovak Academy of Sciences, 05960 Tatranská Lomnica, Slovakia email: [email protected]
P. Gömöry
Affiliation:
Astronomical Institute of Slovak Academy of Sciences, 05960 Tatranská Lomnica, Slovakia email: [email protected]
M. Kozák
Affiliation:
Astronomical Institute of Slovak Academy of Sciences, 05960 Tatranská Lomnica, Slovakia email: [email protected]
A. Kučera
Affiliation:
Astronomical Institute of Slovak Academy of Sciences, 05960 Tatranská Lomnica, Slovakia email: [email protected]
J. Rybák
Affiliation:
Astronomical Institute of Slovak Academy of Sciences, 05960 Tatranská Lomnica, Slovakia email: [email protected]
S. Tomczyk
Affiliation:
High Altitude Observatory, National Center for Atmospheric Research, Boulder, CO 80307, USA
S. Sewell
Affiliation:
High Altitude Observatory, National Center for Atmospheric Research, Boulder, CO 80307, USA
P. Aumiller
Affiliation:
High Altitude Observatory, National Center for Atmospheric Research, Boulder, CO 80307, USA
R. Summers
Affiliation:
High Altitude Observatory, National Center for Atmospheric Research, Boulder, CO 80307, USA
L. Sutherland
Affiliation:
High Altitude Observatory, National Center for Atmospheric Research, Boulder, CO 80307, USA
A. Watt
Affiliation:
High Altitude Observatory, National Center for Atmospheric Research, Boulder, CO 80307, USA
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Coronal Multi-channel Polarimeter (CoMP-S), developed by HAO/NCAR, has been introduced to regular operation at the Lomnicky Peak Observatory (High Tatras in northern Slovakia, 2633 m a.s.l.) of the Astronomical Institute of Slovak Academy of Sciences. We present here the technical parameters of the current version of the instrument and its potential for observations of prominences in the visual and near-IR spectral regions. The first results derived from observations of prominences in the Hα emission line taken during a coordinated observing campaign of several instruments in October 2012 are shown here.

Type
Contributed Papers
Copyright
Copyright © International Astronomical Union 2013 

References

Lexa, J., 1966, BAC, 14, 107Google Scholar
Kučera, A., Ambroz, J., Gömöry, P., Kozák, M., & Rybák, J., 2011, Contributions of Astronomical Observatory Skalnate Pleso, 40, 135Google Scholar
Tomczyk, S., Card, G., Darnell, T., Elmore, D.et al., 2008, Sol. Phys., 247, 411CrossRefGoogle Scholar