No CrossRef data available.
Factors Influencing the Robustness and Accuracy of Near Infrared Reflectance Spectroscopy (NIRS) Calibrations for Ps5edicting the Digestibility of Grass Silages
Published online by Cambridge University Press: 24 November 2017
Extract
Earlier studies showed the superiority of NIRS, over fibre measurements, for predicting organic matter digestibility (OMD) in vivo of grass silages. (Barber et al 1990). This system was put into routine use in ADAS in 1989 and after some initial doubts, due to the wider range of the predicted data seen, is now accepted as the best system available for routine use. However, occasional erroneous values were predicted for which there were no obvious explanations, and which resulted in occasional relatively poor repeatability. In common with all NIRS applications it was likely that the sources of the problems contributing to the errors were i) instrumental and environmental noise, ii) sample particle size effects and iii) variable moisture content of the samples. A course of investigation was undertaken with the objective of determining the effects of these on the predicted data.
- Type
- Ruminant Metabolism
- Information
- Proceedings of the British Society of Animal Production (1972) , Volume 1993: Winter meeting , March 1993 , pp. 50
- Copyright
- Copyright © The British Society of Animal Production 1993