Hostname: page-component-586b7cd67f-2plfb Total loading time: 0 Render date: 2024-11-25T23:37:43.514Z Has data issue: false hasContentIssue false

Study on the Effectiveness Evaluation of Personal Protective Equipment for Health Care Staff Trained with Graphical Interpretation and Operation

Published online by Cambridge University Press:  06 May 2019

Yang Sha
Affiliation:
Department of Infectious Diseases, Southwest Hospital of Army Medical University, Chongqing, China
You Jian-Ping
Affiliation:
Department of Infectious Diseases, Southwest Hospital of Army Medical University, Chongqing, China
Zhang Hui-Lan
Affiliation:
Department of Infectious Diseases, Southwest Hospital of Army Medical University, Chongqing, China
Luo Hong-Xia
Affiliation:
Department of Infectious Diseases, Southwest Hospital of Army Medical University, Chongqing, China
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.
Introduction:

Proper use of personal protective equipment (PPE) is essential when facing emerging infectious diseases. Proper training methods can promote the use of the PPE correctly.

Aim:

To explore the effect of the training method of sequential operation training on medical staff to master PPE penetration and removal skills, and to study the memory attenuation after training.

Methods:

Fifteen medical staff with no experience of PPE operation in a hospital were trained to wear PPE in accordance with WHO standards by illustration and sequential operation method. The training included 30 minutes of theoretical teaching and 60 minutes of practical exercises. At the end of the training and 1 week after the training, the training objects were evaluated for PPE operation. A 2.5 x 2.5 cm fluorescent agent was applied on 6 parts, such as hands, chest, abdomen, and knees, to simulate contamination. After taking the PPE off, the parts of the whole body and the inner layer of clothing that were fluorescently contaminated were recorded. The whole operation process was recorded by video to evaluate whether the operation was correct. The error rates of two operations and the contamination position and frequency were compared.

Results:

The error rate of the operating PPE after training was 18.6%, rising to 31.9% after 1 week (Z=16.0, P<0.05). After the training, the average number of contaminated PPE removal was 1.96±1.56, which rose to 2.96±2.03 one month later. The difference was statistically significant (Z=8.92, P<0.05). The main vulnerable sites are the wrist, chest, abdomen, and left calf.

Discussion:

Illustrative sequential operation training is an important means to improve the way for medical staff to wear PPE, but it must be completed more than once to ensure that medical staff can firmly master the skills of wearing and removing PPE.

Type
Poster Presentations
Copyright
© World Association for Disaster and Emergency Medicine 2019