Hostname: page-component-586b7cd67f-rcrh6 Total loading time: 0 Render date: 2024-11-25T05:59:49.150Z Has data issue: false hasContentIssue false

Noise Pollution: Do We Need a Solution? An Analysis of Noise in a Cardiac Care Unit

Published online by Cambridge University Press:  23 May 2016

Kevin M. Ryan*
Affiliation:
Beth Israel Deaconess Medical Center, Department of Emergency Medicine, Boston, Massachusetts USA
Matthew Gagnon
Affiliation:
Worcester Polytechnic Institute, Department of Mechanical Engineering, Worcester, Massachusetts USA
Tyler Hanna
Affiliation:
Worcester Polytechnic Institute, Department of Mechanical Engineering, Worcester, Massachusetts USA
Brad Mello
Affiliation:
Worcester Polytechnic Institute, Department of Mechanical Engineering, Worcester, Massachusetts USA
Mustapha Fofana
Affiliation:
Worcester Polytechnic Institute, Department of Mechanical Engineering, Worcester, Massachusetts USA
Gregory Ciottone
Affiliation:
Beth Israel Deaconess Medical Center, Department of Emergency Medicine, Boston, Massachusetts USA
Michael Molloy
Affiliation:
Beth Israel Deaconess Medical Center, Department of Emergency Medicine, Boston, Massachusetts USA REDSPOT, University of Limerick, Limerick, Ireland
*
Correspondence: Kevin M. Ryan, MD Beth Israel Deaconess Medical Center Fellowship in Disaster Medicine 109 Brookline Ave Boston, Massachusetts 02215 USA E-mail: [email protected]

Abstract

Introduction

Hospitals are meant to be places for respite and healing; however, technological advances and reliance on monitoring alarms has led to the environment becoming increasingly noisy. The coronary care unit (CCU), like the emergency department, provides care to ill patients while being vulnerable to noise pollution. The World Health Organization (WHO; Geneva, Switzerland) recommends that for optimum rest and healing, sound levels should average approximately 30 decibels (dB) with maximum readings less than 40 dB.

Problem

The purpose of this study was to measure and analyze sound levels in three different locations in the CCU, and to review alarm reports in relation to sound levels.

Methods

Over a one-month period, sound recorders (Extech SDL600; Extech Instruments; Nashua, New Hampshire USA) were placed in three separate locations in the CCU at the West Roxbury Veterans’ Administration (VA) Hospital (Roxbury, Massachusetts USA). Sound samples were recorded once per second, stored in Comma Separated Values format for Excel (Microsoft Corporation; Redmond, Washington USA), and then exported to Microsoft Excel. Averages were determined, plotted per hour, and alarm histories were reviewed to determine alarm noise effect on total noise for each location, as well as common alarm occurrences.

Results

Patient Room 1 consistently had the lowest average recordings, though all averages were >40 dB, despite decreases between 10:00 pm and 7:00 am. During daytime hours, recordings maintained levels >50 dB. Overnight noise remained above recommended levels 55.25% of the period in Patient Room 1 and 99.61% of the same time period in Patient Room 7. The nurses’ station remained the loudest location of all three. Alarms per hour ranged from 20-26 during the day. Alarms per day averaged: Patient Room 1-57.17, Patient Room 7-122.03, and the nurses’ station - 562.26. Oxygen saturation alarms accounted for 33.59% of activity, and heart-related (including ST segment and pacemaker) accounted for 49.24% of alarms.

Conclusion

The CCU cares for ill patients requiring constant monitoring. Despite advances in technology, measured noise levels for the hospital studied exceeded WHO standards of 40 dB and peaks of 45 dB, even during night hours when patients require rest. Further work is required to reduce noise levels and examine effects on patient satisfaction, clinical outcomes, and length of stay.

RyanKM , GagnonM , HannaT , MelloB , FofanaM , CiottoneG , MolloyM . Noise Pollution: Do We Need a Solution? An Analysis of Noise in a Cardiac Care Unit. Prehosp Disaster Med. 2016;31(4):432–435.

Type
Original Research
Copyright
© World Association for Disaster and Emergency Medicine 2016 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. World Health Organization. Guidelines for Community Noise. http://whqlibdoc.who.int/hq/1999/a68672.pdf. Published 1999. Accessed May 31, 2015.Google Scholar
2. Hansell, HN. The behavioral effects of noise on man: the patient with “intensive care unit psychosis.” Heart Lung. 1984;13(1):59-65.Google Scholar
3. Darbyshire, JL, Young, JD. An investigation of sound levels on intensive care units with reference to the WHO guidelines. Crit Care. 2013;17(5):R187.Google Scholar
4. Aaron, JN, Carlisle, CC, Carskadon, MA, Meyer, TJ, Hill, NS, Millman, RP. Environmental noise as a cause of sleep disruption in an intermediate respiratory care unit. Sleep. 1996;19(9):707-710.Google Scholar
5. Parthasarathy, S, Tobin, MJ. Sleep in the intensive care unit. Intensive Care Med. 2004;30(2):197-206.Google Scholar
6. Fife, D, Rappaport, E. Noise and hospital stay. Am J Public Health. 1976;66(7):680-681.Google Scholar
7. Baker, CF, Garvin, BJ, Kennedy, CW, Polivka, BJ. The effect of environmental sound and communication on CCU patients’ heart rate and blood pressure. Res Nurs Health. 1993;16(6):415-421.Google Scholar
8. Ely, E, Gautam, S, Margolin, R, et al. The impact of delirium in the intensive care unit on hospital length of stay. Intensive Care Med. 2001;27(12):1892-1900.Google Scholar
9. Milbrandt, EB, Deppen, S, Harrison, PL, et al. Costs associated with delirium in mechanically ventilated patients. Crit Care Med. 2004;32(4):955-962.Google Scholar
10. Center for Hearing and Communication. Common Environmental Noise Levels: How loud is too loud? http://chchearing.org/noise/common-environmental-noise-levels/. Accessed June 1, 2015.Google Scholar
11. Topf, M, Davis, JE. Critical care unit noise and rapid eye movement (REM) sleep. Heart Lung. 1993;22(3):252-258.Google Scholar
12. Buxton, OM, Ellenbogen, JM, Wang, W, et al. Sleep disruption due to hospital noises: a prospective evaluation. Ann Intern Med. 2012;157:170-179.Google Scholar
13. Xie, H, Kang, J, Mills, GH. Behavior observation of major noise sources in critical care wards. J Crit Care. 2013;28(6):109e5-1e18.Google Scholar
14. Van den Boogaard, M, Pickkers, P, Slooter, AJ, et al. Development and validation of PRE-DELIRIC (PREdiction of DELIRium in ICU patients) delirium prediction model for intensive care patients: observational multicenter study. BMJ. 2012;344:e420.Google Scholar
15. Morrison, WE, Hass, EC, Shaffner, DH, Garrett, ES, Fackler, JC. Noise, stress, and annoyance in a pediatric intensive care unit. Crit Care Med. 2003;31(1):113-119.Google Scholar
16. Topf, M, Dillon, E. Noise-induced stress as a predictor of burnout in critical care nurses. Heart Lung. 1988;17(5):567-574.Google Scholar
17. Wallace, CJ, Robins, J, Alvord, LS, Walker, JM. The effect of earplugs on sleep measures during exposure to simulated intensive care unit noise. Am J Crit Care. 1999;8(4):210-219.Google Scholar