I. INTRODUCTION
Next-generation advanced integrated circuit technologies will feature “More than Moore” approaches using the heterogeneous integration of semiconductor-based devices, including multiple silicon die. The development of a non-destructive, in situ metrology that can analyse the warpage or bow of the semiconductor die inside such devices is particularly challenging. Ideally, such a metrology would be capable of real-time measurement of the die warpage during annealing or curing processes, particularly as a means of pinpointing the impact of crucial process steps. A relatively recent survey (Marks et al., Reference Marks, Hassan and Cheong2014) indicated that none of the currently available commercial techniques was capable of in situ and non-destructive measurement of the nature and scale of wafer or die bow/warpage across an entire die. For example, profilometry techniques, such as shadow Moiré interferometry (Post et al., Reference Post, Han and Ifju2000; Han, Reference Han2003), measure only the macroscopic warpage of the complete package, not the chip itself. Furthermore, there is no consensus on the implementation of in situ analysis of die warpage when the package is undergoing thermal processing steps or is otherwise at an elevated temperature.
The use of high-resolution X-ray diffraction to measure quantitatively the deflection of encapsulated silicon wafers was reported by Toda and Ikarashi (Reference Toda and Ikarashi2010), who were able to separate signals from three stacked chips within a single package. Wong et al. (Reference Wong, Bennett, Manessis, Danilewsky and McNally2014) subsequently used such a scanning diffractometry method to show the impact of high temperature on an encapsulated die. Both groups used conventional laboratory X-ray generators. X-ray diffraction imaging (XRDI), originally known as X-ray topography (Bowen and Tanner, Reference Bowen and Tanner2006), has been used in section geometry to image localized defects in single crystals since its invention by the late (Lang, Reference Lang1957). Using synchrotron radiation of typically 32 keV, it has been shown that white beam section topography imaging can be used to map quantitatively the warpage in fully packaged silicon die (Bose et al., Reference Bose, Vijayaraghavan, Cowley, Cherman, Tanner, Danilewsky, De Wolf and McNally2016; Cowley et al., Reference Cowley, Ivankovic, Wong, Bennett, Danilewsky, Gonzalez, Cherman, Vandervelde, De Wolf and McNally2016; Tanner et al., Reference Tanner, Danilewsky, Vijayaraghavan, Cowley and McNally2017).
Despite the success of this technique with the continuous spectrum of white synchrotron radiation, for the technique to have a significant industrial application, it must be transferred for use with a conventional X-ray source and located in fab or, at the very least, in an on-site research laboratory. In this paper, the application of the synchrotron-based technique to the study of the warpage as a function of temperature in a commercial quad-flat no-lead (QFN) chip package is illustratedand the possible use of a divergent beam and characteristic X-ray lines for the warpage measurement of such encapsulated die using a laboratory X-ray source is explored. All synchrotron radiation data presented here were collected at the beamline B16 of the Diamond Light Source, Didcot, UK.
II. SYNCHROTRON RADIATION METHODOLOGY
The white beam section imaging technique relies on positioning a slit, typically 15 μm × 10 mm, before the sample, which is adjusted such that a narrow ribbon beam is diffracted perpendicular to the extended length [Figure 1(a)]. Defects such as dislocations show as bright regions in the image stripe. For a flat, undistorted wafer, such as the (0001) SiC crystal illustrated in Figures 1(b) and 1(c), when the crystal is translated, different defects, or parts of defects, appear in the image, but the overall image position remains in the same place. There is no displacement of the overall image stripe between Figures 1(b) and 1(c).
However, if the wafer is distorted, as in Figure 2(a), there is a displacement of the image. Although the white synchrotron radiation beam is highly parallel, if the lattice planes are tilted δθ with respect to the original position, the crystal selects a different wavelength from the continuous spectrum to diffract. Because of the different Bragg angle, it immediately follows that the direction of the diffracted beam is changed by 2δθ and the image is displaced 2Lδθ, where L is the specimen to detector distance. Thus, by simply measuring the image displacement as a function of specimen position, the angular tilt, that is, the warpage, can be mapped directly. For high X-ray energy, there is little sensitivity to dilation. Provided that the radiation is of sufficiently high energy that the diffracted beam is not totally absorbed, silicon die in fully packaged devices can be examined non-destructively. Packages that can be examined successfully [Figure 2(b)] are the micro QFN (uQFN) format, which is 4 × 4 × 0.5 mm (e.g. PIC16LF1827), and the similar QFN format, which is 7 × 7 × 0.75 mm (e.g. AD9253).
Figures 2(c) and 2(d) show images from the 4.5 × 4.5 mm Si die in a QFN Analog Devices AD9253 analog-to-digital converter chip. Each image, recorded in transmission on the Photonic Science X-ray MiniFDI camera system with the white beam at beamline B16 at the Diamond Light Source, took about 500 ms to capture. This interval comprised 300 ms exposure and approximately 200 ms specimen displacement time between each position on the sample. Enough data to reconstruct a complete warpage map can be obtained in under a minute.
XRDI images are sensitive to tilt only in the direction of the diffraction vector g. It is evident from the shape of the image in Figure 2(c) that there is a twist between the centre and edges of the Si die of 0.20 ± 0.01°. Translation of the sample by 2.8 mm results in an overall displacement of the image [Figure 2(d)] and a reversal in the sense of the twist between centre and edges. The tilt between the two translation positions, measured along the line of the die centre, is also 0.2 ± 0.01°. The twist now differs between the two edges, being 0.22° on the left and 0.18° on the right. Absolute accuracy is set primarily by the accuracy of determining the specimen to detector distance; the relative precision of the measurements is about 0.004°.
A. Change in die warpage during heating of AD9253 chip package
The warpage of the AD9253 die was measured, using the above technique at beamline B16 of the Diamond Light Source, as the sample was heated with a carbon heater, with the temperature being monitored with a thermocouple. As the temperature increased, there was an initial reduction in the angular position at the centre of the die [squares in Figure 3(a)], a reversal of the sign of the change in tilt occurring at 100 °C in both of the samples measured. Upon an increase in temperature to 150 °C, the tilt reverted to that at room temperature and at 200 °C, and the tilt further increased. Cooling the sample reversed the process, the angular position again going through a minimum and the final room temperature value being displaced, but by only 0.025 ± 0.006°, from the initial starting value. Across the centre of the die, the twist was almost zero in both samples, and this changed little as a function of temperature [Figure 3(a)]. At the bottom of the sample (y = 0), the tilt at the centre and at the edges (in the x-direction) showed a similar U-shaped variation with temperature. The twist between edge and centre, however, fell as the temperature increased, this variation being approximately linear with temperature when above 50 °C [Figure 3(b)]. Finally, it is noted that, although the tilt at the centre point in the x-direction (x = 2.2 mm) as a function of y-position did not exhibit a monotonic variation at room temperature [Figure 3(c)], at high temperature, the tilt became almost linear with temperature. During manufacture, the device is set in the polymer potting compound of the package at an elevated temperature, of the order of 150 °C. As the polymer cools and becomes solid, the strain in the sample becomes complex, resulting in the non-symmetric tilt and twist behaviour at room temperature. When the temperature is subsequently raised, the polymer reverts to its high-temperature viscous state and the die relaxes back to the simple linear tilt pattern associated with gluing to the lead frame.
While the precision of the measurement of change in tilt is very high for the synchrotron radiation section topography method, the variation in distortion between the AD9253 chips studied was considerable. This contrasted with packages that showed simple paraboloidal warpage, such as the PIC16LF1827 devices discussed below, which were much more reproducible (see also Tanner et al., Reference Tanner, Danilewsky, Vijayaraghavan, Cowley and McNally2017). An example is shown in Figure 4 of the tilt and twist differences across the centres of two AD9253 chips at room temperature and at 150 °C. At room temperature in the as-received state, there is significant difference in the twist across the die, indicated by the different lateral shape of the images. For Chip 1, there was an approximately linear change in twist across the device, whereas Chip 2 showed a bimodal profile, with the twist between the two die edges being almost zero. Upon heating to 150 °C, Chip 1 showed a considerable change in tilt, indicated by the displacement of the whole image, and a reduction in twist, shown by the lower gradient of the line across the page. In contrast, Chip 2 exhibited an almost identical tilt and twist at 150 °C to that at room temperature. There was, however, a similar reversal of overall tilt change upon heating of the two chips, equivalent to Figure 3(a). Presently, it is not possible to provide further statistics on the range of this variability.
III. DIVERGENT BEAM FROM A LABORATORY SOURCE
The X-rays emitted from laboratory X-ray tubes differ from synchrotron radiation, in that they are emitted into 2π solid angles, and although the X-ray spectrum does contain a continuous range of wavelengths in the Bremsstrahlung, the most intense features are the characteristic lines of the element(s) in the source-target material. Thus, exploiting the divergence of the beam and one of the characteristic lines in a quasi-monochromatic mode would seem a promising approach to devising a rapid laboratory technique for warpage measurement. The use of a silver target X-ray tube provides closely spaced characteristic AgKα 1 and AgKα 2 lines at 22.16 keV (0.5594 Å) and 21.99 keV (0.5638 Å), respectively, or the Kβ 1β 3 unresolved doublet of average energy 24.94 keV at 25% of the Kα 1 intensity. All are transmitted with modest attenuation through the uFQN package thickness of 500 μm.
The Bruker JVSensus and JVQC-TT XRDI tools can be equipped with a silver X-ray tube, and although optimized for the study of strains, including those from dislocations, by X-ray topography in single crystals of semiconductors (Atrash et al., Reference Atrash, Meshi, Krokhmal, Ryan, Wormington and Sherman2017), they have a beam divergence that makes them appropriate for feasibility studies. The tools are based on the BedeScan concept originally developed by Bowen et al. (Reference Bowen, Wormington and Feichtinger2003) and were initially operated in their standard geometry, with a 200 μm (adjustable) slit located midway between the source and the sample. The geometry is shown in Figure 5(a), with the sample to detector distance L being variable. With such a divergent beam, at the detector, one effectively observes the spectrum from the X-ray tube spread out in space. When set at the appropriate angle, the Kα 1 and Kα 2 characteristic lines are observed [Figure 5(b)], the line width being set by the fundamental linewidth of the atomic transition, convolved with the slit function. For an undistorted wafer, straight lines result, which do not change position as the wafer is translated across the beam for a fixed position of the detector. When the wafer is warped, characteristic X-rays from a different point on the X-ray tube target can satisfy the Bragg angle at an absolute angle that differs by the wafer tilt. Because these beams of characteristic radiation travel in different directions to that in the undistorted wafer, and there is no slit between wafer and detector, the characteristic lines are displaced by (L + D)δθ because of the tilt δθ as the warped wafer is scanned across the slit [Figure 5(c)]. Here, D is the distance between slits and sample. Note that for the PIC16LF1827 microcontroller illustrated below, there is little twist across the die. Radiographs showed the die to be a square of side 2.1 mm.
The beam divergence in the diffracting plane is 0.2° for the standard JVSensus geometry, so this sets a limit to the angular range of warpage that can be measured. Furthermore, in the standard geometry [Figure 5(a)], with respect to the narrow slits, the position on the die at which the diffraction occurs changes as the warped sample is translated. There is, therefore, no simple correspondence between the change in position on the detector and the warpage angle. This problem can be minimized by locating the slit close to the sample, and the data shown in Figure 5 were collected on a Bruker JVQC-TT XRDI tool with a 200 μm wide slit located about 10 mm from the sample. However, this also reduced the divergence, and hence the range of tilt sampled, to 0.11°. If the warpage is uniform, that is the change in angle is linear with distance along the die, it is possible to correct for the geometric shift analytically.
Unlike the QFN AD9253 chip, the image displacement from the uQFN format Microchip PIC16LF1827 microcontroller was found to be linear with translation, and when the small correction is made for the change in sampling position, the gradient k of the true tilt as a function of distance was determined to be 0.30 ± 0.02° mm−1, consistent with that found at the synchrotron radiation source. The absolute displacement Δz of the die is related to the incremental change in angular displacement dθ with distance increment dy in the surface by
This parabolic displacement (Figure 6), which is found in both of the two orthogonal directions in the plane of the die, is characteristic of the warpage when a small die is fixed to the lead frame with glue at each of the four corners and would suggest that the distortion of the small die by the encapsulation polymer is less than that of the larger silicon pieces in the QFN packages.
The geometry of Figure 5 has a further important limitation. Warpage can be measured accurately only when, viewed from the detector, the curvature of the die is concave, as illustrated in Figure 5. If the warpage is convex, as illustrated in Figure 7(a), the silicon die becomes effectively a curved crystal focusing monochromator. From any point on the source, the convex curvature of the silicon die crystal enables the diffraction angle for the characteristic lines to be simultaneously satisfied across a range of positions on the crystal. This effect is most pronounced when the Bruker tools are used in standard geometry. As shown in Figure 7(b), the image is then not a pair of sharp lines, but a blurred and wide image. For small warpage, this can be partially rectified by locating the slit close to the sample. For the PIC16LF1827 chip shown in Figure 5, with the slit 10 mm being from the sample, the broadening was reduced to approximately the separation of the Kα 1 and Kα 2 lines.
For simple warpage, such as in the PIC16LF1827 chip, by maintaining the orientation of the device to be concave with respect to the X-ray exit beams, sharp lines can readily be obtained, and high-resolution warpage mapping achieved with the divergent beam geometry. However, in the case of four-die stacks fabricated for the authors at IMEC in Leuven, Belgium, the curvature is much more complex. These unencapsulated devices consist of an interconnected four-die stack, the three top dies being 5 mm × 5 mm × 50 μm thick, while the bottom die is 8 mm × 8 mm × 200 μm thick. With the white beam synchrotron radiation section topography technique [Figures 8(a)–8(c)], there are four very clearly separated images from the individual dies, with the thick bottom die being almost undistorted, while the top three thin dies are very strongly warped by the interconnect and die adhesion processes. Despite the high resolution of the images, it is difficult to track the tilt as a function of position of the individual thin die when the curvature changes rapidly from convex to concave over quite a small die displacement and where there is also substantial twist, such as illustrated in Figure 8. With the divergent beam technique, it becomes even more difficult to follow the individual die images [Figure 8(d)]. The broadening of the image as the curvature becomes convex with respect to the detector brings all the individual images together. Although there are two clear α 1 and α 2 images from each die when the curvature is concave, this is not the case when it becomes convex.
IV. CONCLUSION
The effectiveness of XRDI for the examination and measurement of the warpage of die in fully packaged chips at synchrotron radiation sources is now fully established. Restrictions on the type of package capable of being examined are primarily set by the X-ray energy (wavelength) limit of the bending magnet or insertion devices used. It has been shown that for a standard bending magnet such as at B16 of the Diamond Light Source, QFN and uQFN format chips can be studied satisfactorily. When one such chip, the AD9253, was raised in temperature to 200 °C, the curvature of the 4.5 × 4.5 mm die simplified, resulting in an approximately constant gradient of tilt with respect to position across the die surface. This, together with a reduction in twist across the die and approximate reproducibility of the warpage on subsequent cooling, suggests that the curvature from gluing the sample was of simple paraboloidal form prior to the polymer encapsulant being applied. As this cooled and hardened, the strains became more non-uniform.
The divergent beam quasi-monochromatic method, when used with a silver anode X-ray tube, appears to have the potential for such studies in the laboratory or fab. While the Bruker JVSensus and JVQC-TT XRDI tools, to which the authors were kindly granted access, are optimized for imaging strains and thus are not totally appropriate for warpage measurement in their standard configuration, they do amply demonstrate the feasibility of the method. Key limitations of the current tools are a limited divergence, and because of the separation of slit from sample, there is a broadening of the characteristic line images when the die is convex with respect to the detector. For a commercial inspection tool, this blurring could be minimized by restriction to a single Bragg angle and having the slit assembly surface oriented parallel to the sample, thus enabling scanning with a very small slit-sample distance.
ACKNOWLEDGEMENTS
We thank the Diamond Light Source (UK) for access to beamline B16 and Kawal Sawhney, Igor Dolbnya, Ian Pape, and Andrew Malandain for their outstanding technical support, together with Rajani Vijayaraghavan and Billy Roarty at Dublin City University. Paul Ryan, David Jacques, Oliver Whear, and Tamzin Lafford of Bruker Semi X-ray, Durham, UK, are thanked for access to Bruker JVSensus and JVQC-TT diffraction imaging tools and assistance with data collection. Vladimir Cherman of IMEC, Leuven, is thanked for the fabrication of the four-chip stacked sample. Some of the research reported here has been supported by the project CALIPSOplus under Grant Agreement No. 730872 from the EU Framework Programme for Research and Innovation HORIZON 2020. This publication was supported in part by Science Foundation Ireland (SFI) through the I-Form Advanced Manufacturing Research Centre (Grant No. 16/RC/3872).