Hostname: page-component-78c5997874-mlc7c Total loading time: 0 Render date: 2024-11-19T13:22:56.007Z Has data issue: false hasContentIssue false

Powder X-ray diffraction of 1-(4-Nitrophenyl)-2-piperidinone, C11H12N2O3

Published online by Cambridge University Press:  13 August 2015

Qing Wang
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
Xin Nuo Xiong
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
Jia Wei He
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
Pei Xiao Tang
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
Hui Li*
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
*
a)Author to whom correspondence should be addressed. Electronic mail: [email protected]

Abstract

X-ray powder diffraction data for 1-(4-Nitrophenyl)-2-piperidinone, C11H12N2O3, are reported [a = 9.514(3) Å, b = 12.308(6) Å, c = 9.175(1) Å, α = 90°, β = 91.811(2)°, γ = 90°, V = 1073.94 Å3, Z = 4, ρcal = 1.362 g cm−3 and space group P21/n]. All measured lines were indexed and are consistent with the P21/n space group. No detectable impurities were observed.

Type
Rapid Communication
Copyright
Copyright © International Centre for Diffraction Data 2015 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Boultif, A. and Louër, D. (1991). “Indexing of powder diffraction patterns for low-symmetry lattices by the successive dichotomy method,” J. Appl. Crystallogr. 24, 987993.CrossRefGoogle Scholar
de Wolff, P. M. (1968). “A simplified criterion for the reliability of a powder pattern,” J. Appl. Crystallogr. 1, 108113.CrossRefGoogle Scholar
Jiang, J. and Ji, Y. (2013). “Alternate synthesis of apixaban (BMS-562247), an inhibitor of blood coagulation factor Xa,” Synth. Commun. 43(1), 7279.Google Scholar
Pawley, G. S. (1981). “Unit-cell refinement from powder diffraction scans,” J. Appl. Crystallogr. 14(6), 357361.CrossRefGoogle Scholar
Smith, G. S. and Snyder, R. L. (1979). “FN: a criterion for rating powder diffraction patterns and evaluating the reliability of powder indexing,” J. Appl. Crystallogr. 12, 6065.CrossRefGoogle Scholar
Zikria, J. and Ansell, J. (2009). “Oral anticoagulation with factor Xa and thrombin inhibitors: is there an alternative to warfarin?,” Discov. Med. 8(43), 196203.Google Scholar
Supplementary material: File

Wang supplementary material

Wang supplementary material 1

Download Wang supplementary material(File)
File 199.1 KB
Supplementary material: File

Wang supplementary material

Wang supplementary material 2

Download Wang supplementary material(File)
File 32.1 KB