Hostname: page-component-586b7cd67f-2brh9 Total loading time: 0 Render date: 2024-11-23T04:42:27.466Z Has data issue: false hasContentIssue false

Enhancement of XRF intensity by using Au-coated glass monocapillary

Published online by Cambridge University Press:  05 March 2012

Takashi Nakazawa*
Affiliation:
Graduate School of Engineering, Osaka City University, 3-3-138 Sugimoto, Sumiyoshi-ku, Osaka 558-8585, Japan
Kazuhiko Nakano
Affiliation:
Graduate School of Engineering, Osaka City University, 3-3-138 Sugimoto, Sumiyoshi-ku, Osaka 558-8585, Japan
Masaru Yoshida
Affiliation:
Adachi New Industrial Co., Ltd., 1-14-20 Hori Tachiuri, Nishi-ku, Osaka 550-0012, Japan
Kouichi Tsuji
Affiliation:
Graduate School of Engineering, Osaka City University, 3-3-138 Sugimoto, Sumiyoshi-ku, Osaka 558-8585, Japan
*
a)Author to whom correspondence should be addressed. Electronic mail: [email protected]

Abstract

Results on using X-ray optics with a monocapillary attached to a microfocus Mo X-ray tube for a high-intensity XRF analysis are reported. Au-coated glass monocapillaries with 400 and 700 μm inner diameters were used to obtain focused and intensive incident Mo X-rays for the measurements of XRF intensities from pure metal samples. Intensity enhancements obtained by using the Au-coated monocapillaries were found to be up to 1.5 times higher than those obtained by using similar inner diameter uncoated glass capillaries. The XRF intensity profiles were measured by the wire scanning method to investigate the reasons. The traces of the incident X-rays were calculated by taking into account of X-ray total reflection of the incident X-rays from the inner wall of the capillaries. The calculated XRF intensity profiles agree with those of the measured XRF intensity profiles. The observed enhancements in XRF intensity were the results of the incident X-rays emitted from the Mo X-ray tube being totally reflected on the inner wall of the Au-coated monocapillaries.

Type
Technical Articles
Copyright
Copyright © Cambridge University Press 2011

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Bjeoumikhov, A., Langhoff, N., Bjeoumikhova, S., and Wedell, R. (2005). “Capillary optics for micro X-ray fluorescence analysis,” Rev. Sci. Instrum. RSINAK 76, 063115. 10.1063/1.1938847CrossRefGoogle Scholar
Hosokawa, Y. (2004). X-Ray Spectrometry: Recent Technological Advances, edited by Tsuji, K., Injuk, J., and Van Grieken, R. (Wiley, England), p. 80. 10.1002/0470020431Google Scholar
Jones, K. W. (1993). Handbook of X-Ray Spectrometry, edited by Van Grieken, R. and Markowicz, A. A. (Dekker, New York), p. 418.Google Scholar
Klockenkämper, R. (1996). Total-Reflection X-Ray Fluorescence Analysis (Wiley, New York), p. 30.Google Scholar
Nozaki, H. and Nakazawa, H. (1986). “Conical-type X-ray guide tube for diffraction experiments with small crystals,” J. Appl. Crystallogr. JACGAR 19, 453455. 10.1107/S0021889886088969CrossRefGoogle Scholar
Ohzawa, S., Komatani, S., and Obori, K. (2004). “High intensity monocapillary X-ray guide tube with 10-micrometer spatial resolution for analytical X-ray microscope,” Spectrochim. Acta, Part B SAASBH 59, 12951299. 10.1016/j.sab.2004.05.025CrossRefGoogle Scholar
Rindby, A., Adams, F., Engstrom, P.(2000). Microscopic X-Ray Fluorescence Analysis, edited by Janssens, K., Adams, F., and Rindby, A. (Wiley, England), p. 77.Google Scholar
Yamamoto, N. and Hosokawa, Y. (1988). “Development of an Innovative 5 μm∅ focused X-ray beam energy-dispersive spectrometer and its applications,” Jpn. J. Appl. Phys., Part 2 JAPLD8 27, L2203L2206. 10.1143/JJAP.27.L2203CrossRefGoogle Scholar