Hostname: page-component-78c5997874-fbnjt Total loading time: 0 Render date: 2024-11-19T01:56:30.909Z Has data issue: false hasContentIssue false

Elemental mapping in slices of human brain by SR-μXRF

Published online by Cambridge University Press:  01 March 2012

N. Zoeger*
Affiliation:
Atominstitut, TU-Wien, A-1020 Vienna, Austria
C. Streli
Affiliation:
Atominstitut, TU-Wien, A-1020 Vienna, Austria
P. Wobrauschek
Affiliation:
Atominstitut, TU-Wien, A-1020 Vienna, Austria
C. Jokubonis
Affiliation:
Atominstitut, TU-Wien, A-1020 Vienna, Austria
G. Pepponi
Affiliation:
ITC-irst Centro per la Ricerca Scientifica e Tecnologica, via Sommarive 18, 38050 Povo, Trento, Italy
P. Roschger
Affiliation:
Ludwig Boltzmann Institute of Osteology at the Hanusch Hospital of WGKK and AUVA Trauma Centre Meidling, 4th Medical Department, Hanusch Hospital, Vienna, Austria
S. Bohic
Affiliation:
Micro-FID ID 22, ESRF, BP 220, 38043 Grenoble, France
W. Osterode
Affiliation:
Universitätsklinik für Innere Medizin IV, Vienna, Austria
*
a)Electronic mail: [email protected]

Abstract

Cognitive deficits are repeatedly described with Pb exposure, but little is known about the distribution of lead in brain. To determine the local distribution of lead (Pb) and other trace elements, X-ray fluorescence spectroscopy measurements have been performed, using a microbeam setup and highest flux synchrotron radiation. Experiments have been carried out at ID-22, ESRF, Grenoble, France. The installed microprobe setup provides a monochromatic beam (16 keV) from an undulator station focused by Kirkpatrick-Baez X-ray optics to a spot size of 5 μm×3 μm. Brain slices from frontal cortex, thalamus, and hippocampus have been investigated (20 μm thickness, imbedded in paraffin and mounted on kapton foils). In general no significant increase in fluorescence intensities could be detected in one of the investigated brain compartments. Pb and other (trace) elements such as S, Ca, Fe, Cu, Zn, and Br could be detected in all samples and showed strong inhomogeneities within the analysed areas. While S, Ca, Fe, Cu, Zn, and Br could be clearly assigned to brain vessel structures (blood vessels, plexus choroidei), Pb was very inhomogeneously distributed. The local distribution of the detected elements in various brain structures will be discussed.

Type
XRF Characterization
Copyright
Copyright © Cambridge University Press 2005

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Barth, A., Schaffer, A., Osterode, W. et al. (2002). “Reduced cognitive abilities in lead-exposed men,” Int. Arch. Occup. Environ. Health ZZZZZZ 75, 394398.Google Scholar
Scheuhammer, A.-M., and Cherian, M.-G. (1982). “The regional distribution of lead in normal rat brain,” Neurotoxicology NRTXDN 3, 8592.Google ScholarPubMed
Somogyi, A., Drakopulos, M., Vincze, L., Vekemans, B., Cameranik, C., Janssens, K., Snigirev, A., and Adams, F. (2001). “ID18F: a new micro-x-ray fluorescence end-station at the European Synchrotron Radiation Facility (ESRF): preliminary results,” X-Ray Spectrom. XRSPAX 30, 242252.Google Scholar
Todd, A. C. et al. (2002). “L-shell X-ray fluorescence measurements of lead in bone: Accuracy and precision,” Phys. Med. Biol. PHMBA7 47, 13991419.CrossRefGoogle ScholarPubMed
Widzowski, D.-V., and Cory-Slechta, D.-A. (1994). “Homogeneity of regional brain lead concentrations,” Neurotoxicology NRTXDN 15, 295307.Google ScholarPubMed
Wobrauschek, P., Pepponi, G., Streli, C., Jokubonis, C., Falkenberg, G., and Osterode, W. (2002b). “SR-XRF investigation of human bone,” Adv. X-Ray Anal. AXRAAA 45, 478484.Google Scholar
Wobrauschek, P., Streli, C., Pepponi, G., Zamini, S., Zoeger, N., Falkenberg, G., and Osterode, W. (2001). “Micro-XRF investigation of human bone,” Hasylab Annual Report 2001, pp. 903904.Google Scholar
Wobrauschek, P., Zöger, N., Pepponi, G., Streli, C., Falkenberg, G., and Osterode, W. (2002a). “Variations in Pb and Ca concentrations at bone transition zones determined by SR-XRF with a microbeam at BL L,” Hasylab Annual Report 2002.Google Scholar