Hostname: page-component-78c5997874-94fs2 Total loading time: 0 Render date: 2024-11-09T06:26:14.020Z Has data issue: false hasContentIssue false

Time Difference of Arrival Based Cancer Tumor Localization Using Magnetic Nano Particles Induced Acoustic Signals

Published online by Cambridge University Press:  22 November 2012

Adi Tsalach
Affiliation:
Department of Biomedical Engineering, Tel Aviv University, Israel
Idan Steinberg
Affiliation:
Department of Biomedical Engineering, Tel Aviv University, Israel
Israel Gannot
Affiliation:
Department of Biomedical Engineering, Tel Aviv University, Israel
Get access

Abstract

Cancer is a major public health problem worldwide, especially in developed countries.Early detection of the cancer can greatly increase both survival rates and quality of life for patients. A magnto-acoustic based method had been previously proposed for early tumor detection, in a minimal invasive procedure, using magnetic nanoparticles (MNPs). However, in order to accompany tumor identification with immediate treatment, a complementary tumor localization algorithm was needed. Therefore, our objective was to measure the acoustic signals generated by the MNP conjugated tumor in an optimal multi sensor array and estimate the 3D location of the tumor in real time. A Time Difference of Arrival (TDOA) based localization algorithm was developed, and implemented in computerized simulations on the breast tissue geometry. Tumor localization feasibility and the hyperbolic positioning algorithm performance were evaluated. Overall performance yielded localization with a median Euclidean distance of 2.8mm. Such performance indicates that tumor localization was estimated with high accuracy, and suggests that the combination of magneto-acoustic detection along with a TDOA based localization algorithm can produce an efficient tumor diagnostic system. It enables the detection of tumor presence, as well as the triangulation of its location, and can be further developed into a powerful “image and treat” system.

Type
Articles
Copyright
Copyright © Materials Research Society 2012 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Agnihotri, S.A., Mallikarjuna, N.N., and Aminabhavi, T.M., J. Control. Release, 100, 5(2004).CrossRefGoogle Scholar
Cho, K., Wang, X., Nie, S. and Shin, D.M., Clin. Cancer Res., 14, 1310(2008).CrossRefGoogle Scholar
Soppimath, K.S., Aminabhavi, T.M., Kulkarni, A.R. and Rudzinski, W.E., J. Control. Release, 70, 1(2001).CrossRefGoogle Scholar
Lee, I.S., Lee, N., Park, J., Kim, B.H., Yi, Y.W., Kim, T., Kim, T.K., Lee, I.H., Paik, S.R. and Hyeon, T., J. Am. Chem. Soc., 128, 10658(2006).CrossRefGoogle Scholar
Moeser, G.D., Roach, K.A., Green, W.H., Alan Hatton, T. and Laibinis, P.E. AIChE J., 50, 2835(2004).CrossRefGoogle Scholar
Society, A.C., Cancer Facts & Figures, A.C. Society, Editor 2012.Google Scholar
Artemov, D., Mori, N., Okollie, B. and Bhujwalla, Z.M. Magn. Reson. Med., 49, 403(2003).CrossRefGoogle Scholar
Ito, A., Kuga, Y., Honda, H., Kikkawa, H., Horiuchi, A., Watanabe, Y. and Kobayashi, T., Cancer Lett., 212, 167(2004).CrossRefGoogle Scholar
Kalambur, V.S., Han, B., Hammer, B.E., Shield, T.W. and Bischof, J.C., Nanotechnology, 16, 1221(2005).CrossRefGoogle Scholar
Le, B., Shinkai, M., Kitade, T., Honda, H., Yoshida, J., Wakabayashi, T. and Kobayashi, T., J. Chem. Eng. Jpn., 34, 66(2001).CrossRefGoogle Scholar
Pankhurst, Q.A., Connolly, J., Jones, SK and Dobson, J., J. Phys. D App. Phys., 36, 167(2003).CrossRefGoogle Scholar
Hahn, M.A., Singh, A.K., Sharma, P., Brown, S.C. and Moudgil, B.M. Anal. Bioanal. Chem. 399, 3(2011).CrossRefGoogle Scholar
Gescheit, I.M., Ben-David, M., and Gannot, I., Advances in Optical Technologies, 2008.Google Scholar
Levy, A., Dayan, A., Ben-David, M. and Gannot, I., Nanomed.-Nanotechnol. 6, 786(2010).CrossRefGoogle Scholar
Steinberg, I., Ben-David, M., and Gannot, I., Nanomed.-Nanotechnol. 7, 564(2011).Google Scholar
Torrieri, D.J., IEEE T.Aero.Elec. Sys., 2, 183(1984).CrossRefGoogle Scholar
Chan, Y. and Ho, K., IEEE T.Signal Proc., 42, 1905(1994).CrossRefGoogle Scholar
Foy, W.H., IEEE T. Aero. Elec. Sys., 2, 187(1976).CrossRefGoogle Scholar
Smith, J. and Abel, J., IEEE T. Acoust.Spee., 35, 1661(1987).CrossRefGoogle Scholar
Yang, B. and Scheuing, J.. Cramer-Rao bound and optimum sensor array for source localization from time differences of arrival, IEEE(2005).Google Scholar
Ryu, K.S. and Kishk, A.A., IEEE T. Antenn. Propag., 99, 1(2011).Google Scholar
Fluckiger, M. and Nelson, B.J.. Ultrasound emitter localization in heterogeneous media, IEEE (2007).CrossRefGoogle ScholarPubMed
Nagy, Z., Fluckiger, M., Ergeneman, O., Pané, S., Probst, M. and Nelson, B.J., A wireless acoustic emitter for passive localization in liquids. IEEE(2009).CrossRefGoogle Scholar
Wells, P., Ultrasound Med.Bio., 1, 369(1975).CrossRefGoogle Scholar
Zastrow, E., Davis, S.K., Lazebnik, M., Kelcz, F., Van Veen, B.D. and Hagness, S.C., IEEE T. Biomed. Eng., 55, 2792(2008).CrossRefGoogle Scholar
Ramsay, D., Kent, JC, Hartmann, RA and Hartmann, PE, J. Anat., 206, 525(2005).CrossRefGoogle Scholar
Wells, P.N.T., Reports Prog. Phys., 62, 671(1999).CrossRefGoogle Scholar
Breast Cancer Facts & Figures 2011-2012, American Cancer Society, Inc.: Atlanta.Google Scholar
Blandin, C., Vincent, E., and Ozerov, A.. Multi-source TDOA estimation using SNR-based angular spectra, IEEE(2011).CrossRefGoogle Scholar
Sheng, X. and Hu, Y.H., IEEE T.Signal Proc., 53, 44(2005).CrossRefGoogle Scholar
Kay, S.M., Fundamentals of Statistical Signal Processing: Estimation Theory. Vol. 1. 1993: Prentice Hall.Google Scholar