Hostname: page-component-586b7cd67f-2plfb Total loading time: 0 Render date: 2024-11-25T15:30:58.502Z Has data issue: false hasContentIssue false

Study of TaSi2-Si Crystals with High Energy Synchrotron Radiation as Tunable Wide-bandpass Monochromator and Analyzer Optics

Published online by Cambridge University Press:  21 March 2011

U. Rütt
Affiliation:
Materials Science Division, Argonne National Lab, Argonne, IL, USA
S.R. Stock
Affiliation:
School of Materials Sci & Eng, Georgia Inst of Technology, Atlanta, GA 30332-0245, USA
Z.U. Rek
Affiliation:
Stanford Synchrotron Radiation Lab, Stanford, CA, USA
Get access

Abstract

Single crystals of the in situ composite TaSi2-Si are candidates for wide bandpass monochromators and analyzers for x-ray experiments. Two large crystals (32 × 39 × 7 mm3 and 32 x 39 x 30 mm3) were studied in detail using 115 keV synchrotron radiation at the BESSRC beamline at the APS. For transmission geometry, the Si(111) reflection and 39 mm crystal thickness, rocking curve widths of 95 arc sec with reflectivities of 50% were measured over the entire crystal. Turning the crystal to an angle of 45° to the incident beam and translating it through the beam allowed investigation of the influence of crystal thickness on diffracted intensity. For sample thicknesses ranging between 5 mm and 12.5 mm, the full width at half maximum (FWHM) of the rocking curve increased linearly from 29 arc sec to 53 arc sec. The greatest gain in integrated intensity was obtained for 8-9 mm thickness where FWHM = 40 arc sec. If this crystal were used as a monochromator for synchrotron radiation, it would provide 40 times more intensity than a perfect silicon crystal and an energy bandwidth of 1 keV at 115 keV photon energy. With the increase of the rocking curve FWHM, a plateau across the peak maximum developed; its width increased from 5 arc sec to 25 arc sec when the crystal thickness increased from 5 mm to 12.5 mm, respectively. This plateau allows these crystals to be used as analyzer crystals in diffraction experiments, i.e., as very narrow slits to suppress background. A plateau width of about 5-20 arc sec for the analyzer crystal is needed to insure that the entire intensity scattered from a sample is delivered to the detector. The simple expedient of changing the crystal thickness alters the plateau width of the analyzer crystal and tunes its acceptance to the needs of the sample under study.

Type
Research Article
Copyright
Copyright © Materials Research Society 2001

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Stock, S.R., Rek, Z.U., Chung, Y.H., Huang, P.C., Ditchek, B.M., J Appl Phys 73 (1993) 17371742.Google Scholar
2. Stock, S.R., Rek, Z.U., Goorsky, M.S., J Appl Phys 79 (1996) 68036810.Google Scholar
3. Neumann, H.-B., Schneider, J.R., Süβenbach, J., Stock, S.R., Rek, Z.U., Nucl Instrum Meth A372 (1996) 551555.Google Scholar
4. Freund, A.K., Munkholm, A., Stock, S.R., Rek, Z.U., in High heat flux and synchrotron radiation beamlines SPIE Vol. 3151 (1997) 287299.Google Scholar
5. Ruett, U., Beno, M.A., Strempfer, J., Jennings, G., Montano, P.A., Nucl Instrum Meth A, in press, 20001.Google Scholar