Hostname: page-component-586b7cd67f-gb8f7 Total loading time: 0 Render date: 2024-11-27T01:36:30.189Z Has data issue: false hasContentIssue false

Soft Dry Electrodes for Electrocardiogram with Conductive Silver Nanowires

Published online by Cambridge University Press:  19 August 2014

Amanda Myers
Affiliation:
Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695
Yong Zhu
Affiliation:
Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695
Get access

Abstract

With increasing attention towards long-term health monitoring, there is a pressing need to create noninvasive sensors that monitor vital bioelectronic signals. Particular importance is placed on measuring electrocardiogram (ECG) signals as heart issues are widespread and can be prevented with the proper warning and care of potential problems. Currently, ECGs are taken in a hospital setting using disposable silver-silver chloride (Ag/AgCl) pre-gelled electrodes. Unfortunately, this cannot translate to a long-term monitoring setting due to the electrolytic gel of the electrodes drying and causing skin irritation. This paper presents a soft, skin-mountable dry electrode based on silver nanowires (AgNWs) for measuring ECG signals that can be used in long-term, wearable health monitoring due to the elimination of the electrolytic gel. The AgNWs are embedded in polydimethylsiloxane (PDMS), which creates a robust design that will not suffer from delamination or cracking problems that can eventually lead to loss of conductivity. The electrode is characterized by electrode-skin impedance as a function of frequency and by the surface resistance as the electrode is stretched. The performance of the dry electrode is evaluated and comparable to that of conventional Ag/AgCl electrodes. The ability of the dry electrode to conform to skin is believed to compensate for the lack of an electrolytic gel.

Type
Articles
Copyright
Copyright © Materials Research Society 2014 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Neuman, M.R., in Medical Instrumentation: Application and Design, 4 th ed , pp. 713 (2010).Google Scholar
Gruetzmann, A., Hansen, S., and Müller, J., “Novel dry electrodes for ECG monitoring,” Physio. Meas., 28, 1375 (2007).CrossRefGoogle ScholarPubMed
Jung, H.-C., Moon, J.-H., Baek, D.-H., Lee, J.-H., Choi, Y.-Y., Hong, J.-S., and Lee, S.-H., “CNT/PDMS composite flexible dry electrodes for long-term ECG monitoring,” IEEE Trans.Bio-med. Eng., 59, 1472 (2012).CrossRefGoogle ScholarPubMed
Baek, J.-Y., An, J.-H., Choi, J.-M., Park, K.-S., and Lee, S.-H., “Flexible polymeric dry electrodes for the long-term monitoring of ECG,” Sens. Act. A: Phys., 143, 423 (2008).CrossRefGoogle Scholar
Salvo, P., Raedt, R., Carrette, E., Schaubroeck, D., Vanfleteren, J., and Cardon, L., “A 3D printed dry electrode for ECG/EEG recording,” Sensors Actuators A: Phys., 174, 96 (2012).CrossRefGoogle Scholar
Ma, R., Kim, D.-H., McCormick, M., Coleman, T., and Rogers, J., “A stretchable electrode array for non-invasive, skin-mounted measurement of electrocardiography (ECG), electromyography (EMG) and electroencephalography (EEG),” Proc. IEEE Eng. Med. Bio. Soc., 6405 (2010).Google Scholar
Chen, C.-Y., Chang, C.-L., Chang, C.-W., Lai, S.-C., Chien, T.-F., Huang, H.-Y., Chiou, J.-C., and Luo, C.-H., “A low-power bio-potential acquisition system with flexible PDMS dry electrodes for portable ubiquitous healthcare applications,” Sensors, 13, 3077 (2013).CrossRefGoogle ScholarPubMed
Marambio-Jones, C. and Hoek, E. M. V., “A review of the antibacterial effects of silver nanomaterials and potential implications for human health and the environment,” J. Nanopart. Res., 12, 1531 (2010).CrossRefGoogle Scholar
Xu, F. and Zhu, Y., “Highly conductive and stretchable silver nanowire conductors,” Adv. Mat., 24, 5117 (2012).CrossRefGoogle ScholarPubMed
Grimnes, S. and Martinsen, Ø. G., in Bioimpedance and Bioelectricity Basics, 2 nd ed , pp. 471 (2008).Google Scholar