Hostname: page-component-586b7cd67f-t7czq Total loading time: 0 Render date: 2024-11-25T18:05:14.687Z Has data issue: false hasContentIssue false

Silicon Cleaning Methods Compared at Metal Concentrations Below 1E10 atoms/cm2

Published online by Cambridge University Press:  10 February 2011

Joseph Ilardi
Affiliation:
Mallinckrodt Baker, Inc., Research and Technology Development Department, Phillipsburg, NJ
Rajananda Saraswati
Affiliation:
Mallinckrodt Baker, Inc., Research and Technology Development Department, Phillipsburg, NJ
George Schwartzkopf
Affiliation:
Mallinckrodt Baker, Inc., Research and Technology Development Department, Phillipsburg, NJ
Get access

Abstract

An alkaline aqueous silicon wafer cleaner has been developed which reduces trace metal contamination levels on “p-type” unpatterned silicon wafers to below 1E10 atoms/cm2 without acidic cleaning. This patented technology uses a specially formulated buffering system consisting of an oxidation resistant chelating agent and salt of a weak acid. The aqueous cleaner maintains a stable pH of about 9.5 over a wide range of dilutions, temperatures, hydrogen peroxide concentrations and bath aging times. A single-step bath, megasonic bath or spray clean with this formulation leaves the chemical oxide on the silicon wafer surface free of particles, atomically smooth, free of organics and lower in trace metal contamination levels than similar surfaces cleaned with conventional formulations.

An analytical method was developed which allows the reliable detection of trace metals on silicon wafer surfaces down to 1E8 atoms/cm2 for aluminum, calcium, copper, iron, nickel, sodium and zinc. The procedure uses an ICP-MS with a concentric nebulizer and a desolvator. The acids used were ultrapure to keep the blanks to a very minimum and analyses were run in a class 10 clean room. The trace metals on the wafer were extracted using known amounts of ultrapure acids and were directly aspirated using a special arrangement with the concentric nebulizer. The J.T. Baker cleaner was compared to and outperformed the conventional RCA-1&2 clean and dilute RCA-1&2 chemistries using ultrapure ammonium hydroxide, hydrochloric acid and hydrogen peroxide.

Type
Research Article
Copyright
Copyright © Materials Research Society 2000

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Kern, W., Puotinen, D.A., RCA Review 31 (2), 187 (1970).Google Scholar
2 D'Emic, C. P., Cohen, S., Zaitz, M. A. in Science and Technology of Semiconductor Surface Preparation, edited by Higashi, G. S., Hirose, M., Raghavan, S., Verhaverbeke, S., (Mater. Res. Soc. Proc. 477, Pittsburgh, PA, 1997) pp. 233239.Google Scholar
3 Ohmi, T., Miyashita, M., Itano, M., Imaoka, T., Kawanabe, I., IEEE Trans. on Elec. Dev. 39 (3), 537 (1992).Google Scholar
4 Gerd, J. N., Kimerling, L. C., J. Electronic Materials, Vol. 24, No. 4, 1995 pp. 397404.Google Scholar
5 Cady, W. A., Varadarajan, M., J. Electrochem. Soc., Vol. 143, No. 6, p. 2,064 (June 1996).Google Scholar
6 Chen, G., Gilton, T., Cartensen, B., Lee, W., Waldo, G., Mitchell, G., Cady, W. A., Greiner, W. C., Ilardi, J. M., (to be published in Mater. Res. Soc. Proc., Pittsburgh, PA, 1999).Google Scholar