Hostname: page-component-cd9895bd7-jkksz Total loading time: 0 Render date: 2024-12-27T01:58:55.546Z Has data issue: false hasContentIssue false

Preparation of a novel anti shrinking agent (SOC DA) and its evaluation in dental resins

Published online by Cambridge University Press:  02 January 2014

Ricardo Acosta Ortiz*
Affiliation:
Centro de Investigación en Química Aplicada, Blvd. Enrique Reyna No. 140 Saltillo Coahuila; México 25294. Tel 52 844 4389844
Luis Alberto Reyna Medina*
Affiliation:
Centro de Investigación en Química Aplicada, Blvd. Enrique Reyna No. 140 Saltillo Coahuila; México 25294. Tel 52 844 4389844
María Lydia Berlanga Duarte
Affiliation:
Centro de Investigación en Química Aplicada, Blvd. Enrique Reyna No. 140 Saltillo Coahuila; México 25294. Tel 52 844 4389844
Aida Esmeralda Garcia Valdez
Affiliation:
Centro de Investigación en Química Aplicada, Blvd. Enrique Reyna No. 140 Saltillo Coahuila; México 25294. Tel 52 844 4389844
Get access

Abstract

In this work is discussed the synthesis of a novel antishrinking agent (SOC DA) and the evaluation of its performance in an acrylic dental resin. SOC DA was photopolymerized in conjunction with the components of a conventional acrylic resin, which includes a mixture of diacrylate monomers [glycerolate bisphenol A dimethacrylate (BIS-GMA) / Urethane dimethacrylate (UDMA) / triethyleneglycol dimethacrylate (TEGDMA)] in 50/30/20 molar ratio). SOC DA was added in a range between 5.0-20.0 mol % with respect to the total amount of moles of the acrylic monomers. It was found that increasing concentrations of SOC DA, promoted higher conversions of the dimethacrylate monomers without decreasing the photopolymerization rate of the acrylate monomers. The study of the effect of SOC DA on the mechanical properties of the dental composite filled with 70 % of silicon dioxide, revealed that the presence of the antishrinking agent improved both the compressive and the flexural strength of the dental materials. Besides, it was found that by using the SOC DA at 20%, the shrinkage was reduced 52%, compared with the same formulation without SOC DA.

Type
Articles
Copyright
Copyright © Materials Research Society 2013 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Bailey, W.J., J. Macromol. Sci. Chem.; A9(5): 849865, (1975)CrossRefGoogle Scholar
Moszner, N., Salz, U., Composites for dental materials, in Polymers for Dental materials, Eds, Shalaby, S.W., Salz, U., CRC Press, Boca Raton, 2007, Chap.2 Google ScholarPubMed
Stansbury, J.W., Polym Prepr (American Chemical Society, Division of Polymer Chemistry) 33(2): 518–19 (1992).Google Scholar
Acosta Ortiz, R., Berlanga Duarte, M.L., Savage Gomez, A.G., Sangermano, M, Garcia Valdez, A.e.; Polymer International, 59, 680685 (2010)Google Scholar
Acosta Ortiz, R., Reyna Medina, L.A., Berlanga Duarte, M.L., Ibarra Samaniego, L., Garcia Valdez, A.E., J. Mater. Sci: Mater med, DOI 10.1007/s10856-013-4959-5 Google Scholar
Acosta Ortiz, R., Berlanga Duarte, M.L., Savage Gomez, A.G., Sangermano, M.; Polymer International, 61, 587595 (2012)CrossRefGoogle Scholar