Hostname: page-component-586b7cd67f-rcrh6 Total loading time: 0 Render date: 2024-11-25T15:26:15.726Z Has data issue: false hasContentIssue false

Novel Applications of the QCM Technique in Biomaterials Science

Published online by Cambridge University Press:  01 February 2011

Candida Costa Silva
Affiliation:
[email protected], National Institutes of Health, Section on Tissue Biophysics and Biomimetics, 9 Memorial Drive, Building 9, Room 1E118, Bethesda, MD, 20892, United States
David C Lin
Affiliation:
[email protected], National Institutes of Health, Bethesda, MD, 20892, United States
Iren Horkayne-Szakaly
Affiliation:
[email protected], National Institutes of Health, Bethesda, MD, 20892, United States
Peter J Basser
Affiliation:
[email protected], National Institutes of Health, Bethesda, MD, 20892, United States
Ferenc Horkay
Affiliation:
[email protected], National Institutes of Health, Bethesda, MD, 20892, United States
Get access

Abstract

A quartz crystal microbalance (QCM) has been used to investigate polymer samples. The vapor sorption of three different polymer samples (poly(vinyl acetate), polybutadiene and polydimethylsiloxane) was studied. The change in resonance frequency of the quartz sensor uniformly coated with polymer films was measured as a function of the film thickness and water absorption at different temperatures. The range of linear frequency vs. mass response was determined in the absence of absorbed water. The glass transition temperature of thin poly(vinyl acetate) films (10 nm <thickness< 1000 nm) was found to be in reasonable agreement with published values for macroscopic samples.

Type
Research Article
Copyright
Copyright © Materials Research Society 2008

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Hascall, V. C and Heinegard, D., J. Biol. Chem. 249, 4242 (1974).Google Scholar
2. Basser, P. J, Schneiderman, R., Bank, R. A., Wachtel, E., Maroudas, A., Arch. Biochem. Biophys. 351, 207 (1998).Google Scholar
3. Sauerbrey, G., Phys. Verh., 8, 113 (1957).Google Scholar
4. Sauerbrey, G., Z. Phys., 155, 206 (1959).Google Scholar
5. Hengerer, A., Decker, J., Prohaskza, E., Hauck, S., Kößlinger, C. and Wolf, H., Biosens. Bioelectron. 14, 139 (1999).Google Scholar
6. Rodahl, M. and Kasemo, B., Sens. Actuators A 54, 448 (1996).Google Scholar
7. Voinova, M. V, Rodahl, M., Jonson, M. and Kasemo, B., Physica Scripta 59, 391 (1999).Google Scholar
8. Voinova, M. V, Jonson, M. and Kasemo, B., Biosens. Bioelectron. 17, 835 (2002).Google Scholar
9. Marx, K. A, Biomacromolecules, 4, 1101 (2003).Google Scholar
10. Horkay, F., Horkayne-Szakaly, I., Basser, P. J, Biomacromolecules 6, 988 (2005).Google Scholar
11. Smith, A. L and Shirazi, H. M, J. Therm. Anal. Calorim. 59, 171 (2000).Google Scholar
12. Sugimoto, I., Nakamura, M., Ogawa, S., Seyama, M. and Katoh, T., Sens. Actuators, B 64, 216 (2000).Google Scholar
13. Wong, H. C, Campbell, S. W and Bhethanabotla, V. R, Fluid Phase Equilib. 171, 181 (2001).Google Scholar
14. www.q-sense.comGoogle Scholar
15. Grimshaw, Scott, Tangidyne Corp., technical bulletin 5 (2007).Google Scholar
16. Sinha, R. and Boyer, R. F, J. Chem. Phys. 37, 1003 (1962).Google Scholar
17. Shen, M. C and Eisenberg, A., Prog. Solid State Chem., 3, 407 (1966); Rubber Chem. Technol., 43, 95, 156 (1970).Google Scholar
18. Blum, F. D, Xu, G., Liang, M. C. G., Macromolecules, 29 (27), 87408745 (1996).Google Scholar