New Techniques for Synchrotron Powder Diffraction Studies

Published online by Cambridge University Press:  15 February 2011

G. S. Knapp
Affiliation:
Material Sciences Division, Argonne National Laboratory, Argonne IL 60439
M. A. Beno
Affiliation:
Material Sciences Division, Argonne National Laboratory, Argonne IL 60439
G. Jennings
Affiliation:
Material Sciences Division, Argonne National Laboratory, Argonne IL 60439
M. Ramanathan
Affiliation:
Material Sciences Division, Argonne National Laboratory, Argonne IL 60439
Get access

Abstract

This manuscript discusses two different powder diffraction methods which possess high resolution, low background and very high counting rates. Both methods utilize analyzer crystals in combination with position sensitive detectors. The first method uses a curved perfect crystal analyzer diffracting in the scattering plane to diffract a range of angles into the position sensitive detector. The second method is somewhat simpler, it uses a graphite analyzer crystal diffracting out of the scattering plane. Applications of these methods to anomalous scattering from both powder and amorphous materials are also discussed. One of the techniques should also be very useful for small angle scattering.

Type
Research Article
Copyright
Copyright © Materials Research Society 1993

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Cox, D. in Handbook on Synchrotron Radiation, Brown, G. S. and Moncton, D. E. Editors, Series Editors E. -E. Koch, T. Sasaki, and H. Winick, North-Holland, New York, ,(1991).Google Scholar
2. Beno, M. A., Knapp, G. S. and Jennings, G., Rev. Sci. Instrum. 63,4134 (1992).Google Scholar
3. Knapp, G. S., Beno, M. A., Jennings, G., Engbretson, M. and Ramanathan, M. to be published in Advances in X-ray Analysis.Google Scholar
4. Beno, M. A. and Knapp, G. S., submitted to Rev. Sci. Instrum. (1993).Google Scholar
5. Knapp, G. S. and Beno, M. A., U. S. Patent Application Serial No. 07/811,060, Filed December 19,1991.Google Scholar
6. Parrish, W., Hart, M., Erickson, C. R., Masciocchi, N. and Huang, T. C., Advances in X-ray Analysis, 29, 243 (1986).Google Scholar
7. Wagner, J. L., Radaelli, P. G., Hinks, D. G., Jorgensen, J. D., Mitchell, J. F., Dabrowski, B., Knapp, G. S. and Beno, M. A., submitted to Physvia C (1993).Google Scholar
8. Knapp, G. S., Beno, M. A., manuscript in preparation.Google Scholar
9. The linear detector we are using was manufactured by ORDELA, INC., Oak Ridge TN, USA.Google Scholar
10. Al2O3, NIST Standard Reference Material, 1976, XRD Flat-Plate Intensity Standard, U. S. Dept. of Commerce, National Institute of Standards & Technology, Gaithersburg, MD 20899.Google Scholar
11. ZYA Grade, Graphite purchased from Union Carbide Inc.Google Scholar