Article contents
Microwave Processing of Tantalum Capacitor Anodes*
Published online by Cambridge University Press: 25 February 2011
Abstract
Porous tantalum anodes were sintered at temperatures from 1600 to 1900°C using a conventional high-vacuum furnace as well as both 2.45 GHz fixed-frequency and 4-8 GHz variable-frequency microwave furnaces. Various insulation and casketing techniques were used to couple the microwave power to the tantalum compacts. Several types of tantalum powder were used to assess the effect of microwave processing on sintered surface area and impurity levels.
Some microwave sintered anodes have an unusual surface rippling not seen on conventionally fired parts. The rippling suggests that a microscopic arcing or plasma might have been generated. Two important effects could be exploited if this phenomenon can be controlled. First, the effective tantalum surface area could be increased, yielding higher capacitance per volume. Second, surface impurities might be cleaned away, allowing the formation of a better dielectric film during the anodization process and, ultimately, higher working voltage.
- Type
- Research Article
- Information
- Copyright
- Copyright © Materials Research Society 1992
Footnotes
Work supported by the U.S. Department of Energy, Office of Energy Research, under contract DE-AC05-840R21400 with Martin Marietta Energy Systems, Inc.
References
REFERENCES
- 1
- Cited by