Hostname: page-component-586b7cd67f-rdxmf Total loading time: 0 Render date: 2024-11-25T17:52:26.741Z Has data issue: false hasContentIssue false

Laser Thermoreflectance Measurement for Evaluating Heat Capacity and Interface Heat Resistance of Low-k Films

Published online by Cambridge University Press:  01 February 2011

Jiping Ye
Affiliation:
[email protected], Nissan ARC Ltd., Rearch Department, 1, Natsushima-cho, Yokosuka, 237-0061, Japan, 81 46 867 5283, 81 46 866 5814
Takeo Okamura
Affiliation:
[email protected], Nissan ARC Ltd., Research Department, 1, Natsushima-cho, Yokosuka, 237-0061, Japan
Shigeo Sato
Affiliation:
[email protected], Nissan ARC Ltd., Research Department, 1, Natsushima-cho, Yokosuka, 237-0061, Japan
Get access

Abstract

A novel technique that combines laser thermoreflectance measurement with the 3-omega method is proposed for evaluating the heat capacity of low-k films and the heat resistance at the interface between the low-k film and Si substrate. It was demonstrated that the heat capacity of thin films and the heat resistance at the interface can be determined by obtaining the heat effusivity of the film from laser thermoreflectance measurements, the total heat resistance obtained with the 3-omerga method, and the film density and thickness found from x-ray reflectivity measurements. The heat capacity of SiOC films was determined to be Cp(SiOC) =1.1 kJ/kgK with interface heat resistance of Rint(SiOC) = -2.37×10−8 m2k/W, while the heat capacity of Th-ox films was determined to be Cp(Th−ox) =0.61 kJ/kgK with Rint(Th−ox) = +1.74×10−8 m2k/W. A DSC heat capacity measurement confirmed the reliability of the evaluated Cp data. XRR and TEM examinations revealed that the negative interface heat resistance exhibited by the SiOC films originated from a high density layer at the interface between the film and Si substrate; and the positive interface heat resistance displayed by the Th-ox films stemmed from atomic defects at the interface between the film and Si substrate. These results confirmed that this method is a reliable and effective method for evaluating the heat capacity of low-k films and the heat resistance at the interface.

Type
Research Article
Copyright
Copyright © Materials Research Society 2007

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1 Hatrori, K., Taketoshi, N., Baba, T., and Ohta, H., Rev. Sci. Instrum, 76, 1 (2006)Google Scholar
2 Cahill, D. G., Rev. Sci. Instrum., 61, 802 (1990).Google Scholar
3 YE, J., Shimizu, S., Sato, S., Kojima, N., and Noro, J., Appl. Phys. Lett. 89. 31913 (2006)Google Scholar