Hostname: page-component-78c5997874-lj6df Total loading time: 0 Render date: 2024-11-05T04:43:29.593Z Has data issue: false hasContentIssue false

Interferometry Techniques on Fusion Plasmas

Published online by Cambridge University Press:  22 February 2011

W. A. Peebles*
Affiliation:
Institute for Plasma and Fusion Research University of California, Los Angeles California 90024
Get access

Abstract

Optical interferometry techniques allow phase changes in a medium to be accurately determined. Since plasmas introduce a phase modification proportional to electron density, interferometry has been used routinely to determine the time development of electron density profiles in magnetic confinement fusion plasmas. The present paper describes the basic principles of interferometry of plasmas and establishes criteria regarding wavelength selection, vibrational phase noise, phase averaging etc. In addition, recent advances at UCLA in interferometry of fusion plasmas will be described. For example, high spatial sampling has allowed the detailed study of MHD phenomena such as sawteeth and Mimov oscillations, and 2-D imaging interferometry has permitted tomographic reconstruction of electron density contours. Difficulties associated with interferometry on future fusion devices, such as CIT, will also be discussed together with possible solutions.

Type
Research Article
Copyright
Copyright © Materials Research Society 1988

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

[1] Luhmann, N.C. Jr., and Peebles, W.A., Rev. Sci. Inst. 5, 279 (1984).Google Scholar
[2]Principles of Optics,” Born, M. and Wolf, E. 6th Edition, Pergamon Press, New York (1980).Google Scholar
[3] Veron, D. in “Infrared and Millimeter Waves,” Vol.2 (Button, K.J. ed.; Academic Press, New York, 1979).Google Scholar
[4] Nagashima, A. in Proc. USA-Japan Workshop on Submillimeter Diagnostic Techniques, Nagoya, Japan, UD-5 FRC-006, January 1982.Google Scholar
[5] DeTemple, T.A. and Danielewicz, E.J. in “Infrared and Millimeter Waves,” Vol.7, Coherent Sources and Applications, Part II (Button, K.J., ed.; Academic Press, New York, 1983).Google Scholar
[6] Kneubuhl, F.K. and Sturzenegger, Ch. in ‘Infrared and Millimeter Waves,’ Vol.3, (Button, K.J., ed.; Academic Press, New York, 1980).Google Scholar
[7] Wolfe, S.M., et al., App. Optics 17, 2645, (1976).Google Scholar
[8] Doyle, E.J., Howard, J., Peebles, W.A., Luhmann, N.C. Jr., Rev. Sci. Inst. 57, (8) 1945 (1986).Google Scholar
[9] Young, P.E., et al., Rev. Sci. Inst. 56, 81 (1985).Google Scholar
[10] Peebles, W.A. et al., Int. Journal of Infrared and Millimeter Waves, 8, 1355 (1987).Google Scholar
[11] Kim, S.K., et al., Phys. Rev. Lett. 60, 577 (1988).Google Scholar
[12] Veron, D. in Proc. Intern. School on Plasma Physics, Varenna, (1982).Google Scholar
[13] Baker, D.R. and Lee, S.T., Rev.Sci. Inst. 49, 919 (1978).Google Scholar
[14] Mansfield, D.K., Johnson, L.C., Int. Journal of Infrared and Millimeter Waves, 1, 631 (1980).Google Scholar
[15] Fetterman, H., et al., App. Phys. Lett. 33, 151, (1978).CrossRefGoogle Scholar
[16] Gull, S.F. and Daniell, G.J., Nature 272 686 (1979).Google Scholar
[17] Rutledge, D.B., et al., in ‘Infrared and Millimeter Waves,’ Vol.10, Chpt. 3, (Button, K.J. ed.; Academic Press, New York, 1983). 0.5Google Scholar
[18] Zweben, S.J., Rev. Sci. Inst. 57, (8), 1723, (1986).Google Scholar
[19] Lehecka, T., Peebles, W.A., Luhmann, N.C. Jr., and Carlstrom, T., to be published in Rev. of Sci. Inst. 1988.Google Scholar
[20] Lehecka, T. et al. to be published Rev. Sci. Inst. 1988.Google Scholar