Hostname: page-component-cd9895bd7-dzt6s Total loading time: 0 Render date: 2024-12-27T02:19:08.607Z Has data issue: false hasContentIssue false

A Hybrid Actuation System (HYBAS) and Aerospace Applications

Published online by Cambridge University Press:  01 February 2011

Ji Su
Affiliation:
Tian-Bing Xu
Affiliation:
[email protected], National Institute of Aerospace, United States
Shujun Zhang
Affiliation:
Thomas R. Shrout
Affiliation:
Qiming Zhang
Affiliation:
Get access

Abstract

An electroactive polymer-ceramic hybrid actuation system (HYBAS) has been developed at NASA Langley Research Center. The system demonstrates significantly-enhanced electromechanical performance by cooperatively utilizing advantages of a combination of electromechanical responses of an electroative polymer (EAP), and an electroactive ceramic single crystal, PZN-PT single crystal. The electroactive elements are driven by a single power source. Recently, a modification of HYBAS has been made to increase the capability of air driving for synthetic jet devices (SJ) used in aerodynamic control technologies. The dependence of the air driving capability of the modified HYBAS on the configuration of the actuating device has been investigated. For this particular application, the modified HYBAS demonstrated a 50% increase in the volume change in the synthetic jet air chamber, as compared with that of the HYBAS without the modification. The theoretical modeling of the performances of the HYBAS is in good agreement with experimental observation. The consistence between the theoretical modeling and experimental test make the design concept an effective route for the development of high performance actuating devices for many applications. The theoretical modeling, fabrication of the HYBAS and the initial experimental results will be presented and discussed.

Type
Research Article
Copyright
Copyright © Materials Research Society 2006

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Galletti, P. M., De Rossi, D. E., and De Reggi, A. S., Editors, Medical Applications of Piezoelectric Polymers, Gordon and Breach Science Publishers, New York, 1988 Google Scholar
2. Uchino, K., Piezoelectric Actuators and Ultrasonic Motors, Kluwer Academic Publisher, Boston, 1997.Google Scholar
3. Lee, Chester, Hong, Guang, Ha, Q. P., and Mallinson, S. G.,, Sensors and Actuators A, 108, 168 (2003).Google Scholar
4. Newnham, R.E., Ann. Rev. Mat. Sci. 16, 47 (1986).Google Scholar
5. Park, S.-E., and Shrout, T. R., J. Appl. Phys., 82 (4), 1804 (1997).Google Scholar
6. Pelrine, R. E., Kornbluh, R. D., and Joseph, J. P., Sensors & Actuators A, 64, 77 (1998).Google Scholar
7. Su, J., Zhang, Q.M., and Ting, R.Y. Appl. Phys. Lett. 71 (3), 386 (1997).Google Scholar
8. Newnham, R. E., Q.C., , Xu, , and Yoshikawa, S., United State Patent 4,999,819 (1991), and 5,276,657 (1994).Google Scholar
9. Cheng, Z.-Y., Xu, T.-B., Zhang, Q. M., Meyer, R. J., Tol, D. V., and Hughes, J., IEEE T. UFFC 49 (9), 1312 (2002).Google Scholar
10. Su, J. and Xu, T.-B., Invention Disclosure filed, LAR-16698–1, August, 2003. andGoogle Scholar
Xu, Tian-Bing and Su, Ji, J. Appl. Phys., 034908, 97 (2005).Google Scholar
11. Xu, H. S., Cheng, Z.-Y., Olson, D., Mai, T., and Zhang, Q. M., Appl. Phys. Lett. 78 (17), 2360 (2001)Google Scholar
12. Xu, T.-B., Cheng, Z-Y., and Zhang, Q. M., Appl. Phys. Lett. 80 (6), 1082 (2002).Google Scholar
13. Newnham, R. E., Q.C., , Xu, , and Yoshikawa, S., United State Patent 4,999,819 (1991), and 5,276,657 (1994).Google Scholar
14. Xu, Tian-Bing and Su, Ji, J. Appl. Phys., 034908, 97 (2005)Google Scholar