Hostname: page-component-78c5997874-v9fdk Total loading time: 0 Render date: 2024-11-17T16:10:23.966Z Has data issue: false hasContentIssue false

High Performance P(VDF-TrFE-CFE) Terpolymer for BioMEMs and Microfluidic Devices

Published online by Cambridge University Press:  01 February 2011

Feng Xia
Affiliation:
Department of Electrical Engineering and Materials Research Institute, The Pennsylvania State University, PA 16802
Rob Klein
Affiliation:
Department of Electrical Engineering and Materials Research Institute, The Pennsylvania State University, PA 16802
Francois Bauer
Affiliation:
Institut Franco-Allemand de Recherches de Saint-Louis, (ISL), 68300 Saint-Louis, France.
Q. M. Zhang
Affiliation:
Department of Electrical Engineering and Materials Research Institute, The Pennsylvania State University, PA 16802
Get access

Abstract

BioMEMs and microfluidic devices have gained a lot of attention in recent years due to their emerging applications in biochemical analysis, medical diagnosis, chemical analysis and synthesis, drug discovery and drug delivery, biosensing and biomimetic systems. The materials requirements for bioMEMs are biocompatible, chemically modifiable, easy to fabricate, economic, compliable and smart. Among various materials, the electroactive polymeric materials can best meet these requirements. Recently, we developed a group of poly(vinylidene fluoride-trifluoroethylene) P(VDF-TrFE) based terpolymers which have very high strain level and high energy density. The longitudinal and transverse strain of these materials can reach about –7% and 4.5%, and the elastic energy density is around 1.1 J/cm3, which are very attractive for the development of polymeric pump, valve and other microfluidic components for all polymer-based bioMEMs and microfluidic integrated system. This paper reports on the recent efforts on the optimization of the terpolymer performance and development of microfluidic components using the electroactive terpolymers for bioMEMs.

Type
Research Article
Copyright
Copyright © Materials Research Society 2004

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Bar-Cohen, Y., (ed.) Electroactive Polymer Actuators as Artificial Muscles, SPIE, Bellingham, WA 2001.Google Scholar
2. Zhang, Q. M., Bharti, V., and Zhao, X., Science, 280, 2101 (1998).10.1126/science.280.5372.2101Google Scholar
3. Xia, F., Li, H., Huang, C., Huang, M. Y. M., Xu, H., Bauer, F., Cheng, Z-Y., and Zhang, Q. M., Proc. SPIE Int. Soc. Opt. Eng. 5051, 133 (2003).Google Scholar
4. Xia, F., Cheng, Z.-Y., Xu, H. S., Li, H. F., Zhang, Q. M., Kavarnos, G. J., Ting, Robert Y., Abdel-Sadek, G., and Belfield, K. D., Adv. Mater. 14 (21), 1574 (2002).10.1002/1521-4095(20021104)14:21<1574::AID-ADMA1574>3.0.CO;2-#3.0.CO;2-#>Google Scholar
5. Xu, H., Cheng, Z.-Y., Olson, D., Mai, T., Zhang, Q. M., Kavarnos, G., Appl. Phys. Lett. 78, 2360 (2001).10.1063/1.1358847Google Scholar
6. Bauer, F., Foousson, E., E., , Zhang, Q. M., and Lee, L. M., Proc. 11th Intern. Symp. on Electrets, 355 (2002).10.1109/ISE.2002.1043017Google Scholar
7. Furukawa, T., Phase Transitions, 18, 143 (1989).10.1080/01411598908206863Google Scholar
8. Klein, R. J., Runt, J., and Zhang, Q. M., Macromolecule, 36, 7220 (2003).10.1021/ma034745bGoogle Scholar
9. Hom, C., Pilgrim, S., Shankar, N., Bridger, K., Masuda, M., Winzer, S., IEEE Trans. Ultrason. Ferro. Freq. Cntr. 41, 542 (1994).10.1109/58.294116Google Scholar