Hostname: page-component-cd9895bd7-hc48f Total loading time: 0 Render date: 2024-12-27T01:41:40.631Z Has data issue: false hasContentIssue false

Electrostatic Field Calculations for Electrophoresis Using Surfaces

Published online by Cambridge University Press:  01 February 2011

Perumal Radha Ramasamy
Affiliation:
[email protected], SUNY - Stony Brook University, Materials Science and Engineering, 317, Old Engineering Building,, SUNY - Stony Brook University, Stony Brook, NY, 11794 2275, United States, 631 793 0683
Raafat M Elmaghrabi
Affiliation:
[email protected], Stony Brook University, Dept of Physiology & Biophysics, T6-170 Health Sciences Center, Stony Brook, NY 11794-8661, Stony Brook, NY, 11794-8661, United States
Gary Halada
Affiliation:
[email protected], Stony Brook University, Materials Science and Engineering, 308 Engineering Building, Stony Brook, NY 11794-2275, Stony Brook, NY, 11794-2275, United States
Get access

Abstract

The distribution of electric field in and near the surface of the electrophoretic cell determines the motion of proteins in the buffer and along the surface. This is a complicated problem, influenced by buffer ion concentration, electrode configuration, and surface and substrate conductivities. Steady state calculations approximating the experimental geometry were made for different arrangements of electrodes using MAFIA (Computer Simulation Technologies) program and ESTAT programs. Electric field distributions in both conducting surfaces like ITO (Indium Tin Oxide) (Kevley Technologies), gold and aluminum and non conducting surfaces were studied. In order to measure the EOF of the buffer neutrally charged fluorescent Poly-Styrene beads of 1 μm diameter were included in the buffer and imaged using confocal microscope. It was observed that the electric filed was highly modified by various factors like the conducting nature of the surface, position of the electrodes, salt concentration in the buffer and distance from the separation surface.

Type
Research Article
Copyright
Copyright © Materials Research Society 2008

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

(1) Spehar, Anna-Maria, Koster, Sander, Linder, Vincent, Kulmala, Sakari, Rooij, Nico F. de, Verpoorte, Elisabeth, Sigrist, Hans and Thormann, Wolfgang, Electrophoresis 3674–3678, 24 (2003).Google Scholar
(2) Jacobson, S. C.; Hergenroder, R.; Koutny, L. B.; Ramsey, J. M. Anal. Chem. 2369–2373, 66 (1994).Google Scholar
(3) Hoagland, D.A., Arvanitidou, E. and Welch, C., Macromolecules 6180 – 6190, 32 (1999).Google Scholar
(4) Griffiths, S. K.; Nilson, R. H. Anal. Chem. 5522–5529, 71(1999).Google Scholar
(5) Sia, Samulel K. and Whitesides, George M., Electrophorsesis 3563 – 3576, 24 (2003).Google Scholar
(6) Ermakov, S. V.; Jacobson, S. C.; Ramsey, J. M. Anal. Chem. 4494–4504, 70 (1998).Google Scholar
(7) Rice, C. L. and Whitehead, R., J. Phys. Chem, 1084 – 1091, 69 (1965).Google Scholar
(8) Cummings, EB, Griffiths, SK and Nilson, RH, Paul, PH, Analytical Chemistry, 2526 – 2532 72 (2000).Google Scholar
(9) Poison, N. A. and Hayes, M.A., Analytical Chemistry, 4455–4459, 71(1999).Google Scholar
(10) Probstein, R. F., Physiochemical Hydrodynamics, John Wiley & Sons Inc, NY, 1993.Google Scholar