Electronic Detection of Nucleic Acid Molecules with a Field-Effect Transistor

Published online by Cambridge University Press:  01 February 2011

Sven Ingebrandt
Affiliation:
Institute of Thin Films and Interfaces (ISG-2), Leo-Brandt Str., Forschungszentrum Jülich, 52428 Jülich, Germany
Yinhua Han
Affiliation:
Institute of Thin Films and Interfaces (ISG-2), Leo-Brandt Str., Forschungszentrum Jülich, 52428 Jülich, Germany
Malla-Reddy Sakkari
Affiliation:
Institute of Thin Films and Interfaces (ISG-2), Leo-Brandt Str., Forschungszentrum Jülich, 52428 Jülich, Germany
Regina Stockmann
Affiliation:
Institute of Thin Films and Interfaces (ISG-2), Leo-Brandt Str., Forschungszentrum Jülich, 52428 Jülich, Germany
Oleksandr Belinskyy
Affiliation:
Institute of Thin Films and Interfaces (ISG-2), Leo-Brandt Str., Forschungszentrum Jülich, 52428 Jülich, Germany
Andreas Offenhäusser
Affiliation:
Institute of Thin Films and Interfaces (ISG-2), Leo-Brandt Str., Forschungszentrum Jülich, 52428 Jülich, Germany
Get access

Abstract

Currently, systems for the detection of nucleic acid sequences, known as DNA-chips, are getting lots of attention. Such systems usually involve either an enzymatic or chemical labelling reaction as part of the detection process. The next generation of DNA-chips aims at a labelfree, fully electronic readout system. Several new approaches to signal generation that avoid a labelling step have been developed in recent years. Besides other surface sensitive measurements the possibility of electrochemical impedance and field-effect measurements for the detection of biomolecules have been discussed. The fully electronic detection of charged biomolecules based on the field-effect principle offers a labelfree method, which combines the unique sensitivity and selectivity of biomolecular recognition reactions with an electronic chip-based readout. In this approach one type of molecules is fixed at a surface and the biomolecular reaction with complementary molecules is detected by change in the drain-source current of the transistor. This change can occur by a change of the interface capacitance of the transistor gate or by change of the surface potential during adsorption of the molecules. At the moment a complete theoretical description of the detection principle is still under discussion. However, the fully electronic readout of biomolecular reactions offers a unique principle for the construction of many different sensors for bioassays. We are working on an approach to detect the hybridization of DNA sequences using electrolyte-oxide-semiconductor field-effect transistor (EOSFET) arrays. This method allows direct and in situ detection of specific DNA sequences without any labelling.

Type
Research Article
Copyright
Copyright © Materials Research Society 2005

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Sutherland, G., Mulley, J., Nucleic Acid Probes, CRC Press: Florida (1989) p 159.Google Scholar
2. Kricka, L. J., Nonisotropic DNA Probe Techniques, Academic Press: Toronto (1992) p 3.Google Scholar
3. Souteyrand, E., Cloarec, J. P., Martin, J. R., Wilson, C., Lawrence, I., Mikkelsen, S., and Lawrence, M. F., Journal of Physical Chemistry B 101 (15), 2980 (1997).Google Scholar
4. Fritz, J., Cooper, E. B., Gaudet, S., Sorger, P. K., and Manalis, S. R., Proceedings of the National Academy of Sciences of the United States of America 99 (22), 14142 (2002).Google Scholar
5. Uslu, F., Ingebrandt, S., Mayer, D., Bocker-Meffert, S., Odenthal, M., and Offenhausser, A., Biosensors & Bioelectronics 19 (12), 1723 (2004).Google Scholar
6. Berggren, C., Stalhandske, P., Brundell, J., and Johansson, G., Electroanalysis 11 (3), 156 (1999).Google Scholar
7. Berney, H., West, J., Haefele, E., Alderman, J., Lane, W., and Collins, J. K., Sensors and Actuators B-Chemical 68 (1–3), 100 (2000).Google Scholar
8. Wang, J., Analytica Chimica Acta 469 (1), 63 (2002).Google Scholar
9. Offenhausser, A., Sprossler, C., Matsuzawa, M., and Knoll, W., Biosensors & Bioelectronics 12 (8), 819 (1997).Google Scholar
10. Ingebrandt, S., Dissertation, Universität Mainz, Germany (2001) http://archimed.uni-mainz.de Google Scholar