No CrossRef data available.
Published online by Cambridge University Press: 22 February 2012
Ribbons of the Ni-44.8wt%Ti shape memory alloy are prepared through the melt spinning technique. The study is focused on investigating the effect of the rapid solidification and grain size at characteristic start martensitic (Ms), final martensitic (Mf), start austenite (As) and final austenite (Af) transformation temperatures. Changes on martensitic transformation temperatures in Ti45Ni55 melt spun ribbons are observed as grain size is reduced. Results of optical microscopy and differential scanning calorimetry (DSC) are used to associate grain size with transformation temperatures.