Article contents
The Effect of Nitrogen Implantation on Martensite in 304 Stainless Steel
Published online by Cambridge University Press: 15 February 2011
Abstract
Martensite will form in austenitic 304 stainless steel when it is deformed. Transmission electron microscope studies show that nitrogen ion implantation causes a reversion of the martensite to austenite. Specimens containing martensite resulting from fine surface polishing and heavy rolling are examined. The transformation is shown not to occur because of temperature increases during implantation. The effect is related to recent wear results in 304 stainless steel.
- Type
- Research Article
- Information
- Copyright
- Copyright © Materials Research Society 1982
References
REFERENCES
1.Handbook of Stainless Steels, eds. Peckner, D. and Bernstein, I. M. (McGraw-Hill, N.Y., 1977), ch. 4.Google Scholar
5.Bykov, V. N., Troyan, V. A., Zdrovtseva, G. G. and Khaimovich, V. S., Phys. Stat. Sol. (a) 32, 53 (1975).Google Scholar
6.Johnson, E., Wohlenberg, T., Grant, W. A., Hansen, P. and Chadderton, L. T., J. Microscopy 116, 77 (1979).Google Scholar
8.Pavlov, P. V., Zorin, E. I., Tetelbaum, D. I., Lesnikov, V. P., Ryzhkov, G. M. and Pavlov, A. V., Phys. Stat. Sol. (a) 19, 373 (1973).Google Scholar
9.Skokan, M. R., Skelton, E. F. and Cukauskas, E., J. Phys. Chem. Sol. 41, 977 (1980).Google Scholar
10.Johnson, E., Littmark, U., Johansen, A. and Christodoulides, C., Report No. 81–07, ISSN 0106–7222, H. C. Orsled Institute, Copenhagen (1981).Google Scholar