Hostname: page-component-586b7cd67f-rdxmf Total loading time: 0 Render date: 2024-11-25T15:30:03.332Z Has data issue: false hasContentIssue false

Development of a High Lateral Resolution Electron Beam Induced Current Technique for Electrical Characterization of InGaN-Based Quantum Well Light Emitting Diodes

Published online by Cambridge University Press:  11 February 2011

Kristin L. Bunker
Affiliation:
Analytical Instrumentation Facility and Materials Science and Engineering Department, North Carolina State University, Box 7531, Raleigh, NC 27695, USA
Juan Carlos Gonzalez
Affiliation:
Analytical Instrumentation Facility and Materials Science and Engineering Department, North Carolina State University, Box 7531, Raleigh, NC 27695, USA
Dale Batchelor
Affiliation:
Analytical Instrumentation Facility and Materials Science and Engineering Department, North Carolina State University, Box 7531, Raleigh, NC 27695, USA
Terrence J. Stark
Affiliation:
Materials Analytical Services, 616 Hutton Street, Suite 101, Raleigh, NC 27606, USA
Phillip E. Russell
Affiliation:
Analytical Instrumentation Facility and Materials Science and Engineering Department, North Carolina State University, Box 7531, Raleigh, NC 27695, USA Materials Analytical Services, 616 Hutton Street, Suite 101, Raleigh, NC 27606, USA
Get access

Abstract

Electron Beam Induced Current (EBIC) is a Scanning Electron Microscope (SEM)-based technique that can provide information on the electrical properties of semiconductor materials and devices. This work focuses on the design and implemenation of an EBIC system in a dedicated Scanning Transmission Electron Microscope (STEM). The STEM-EBIC technique was used in the characterization of an Indium Gallium Nitride (InGaN) quantum well Light Emitting Diode (LED). The conventional “H-bar” Transmission Electron Microscopy (TEM) sample preparation method using Focused Ion Beam Micromachining (FIBM) was adapted to create an electron-transparent membrane approximately 300 nm thick on the sample while preserving the electrical activity of the device. A STEM-EBIC sample holder with two insulated electrical feedthroughs making contact to the thinned LED was designed and custom made for these experiments. The simultaneous collection of Z-contrast images, EBIC images, and In and Al elemental images allowed for the determination of the p-n junction location, AlGaN and GaN barrier layers, and the thin InGaN quantum well layer within the device. The relative position of the p-n junction with respect to the thin InGaN quantum well was found to be (19 ± 3) nm from the center of the InGaN quantum well.

Type
Research Article
Copyright
Copyright © Materials Research Society 2003

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Holt, D.B., Quantitative Scanning Electron Microscopy: Quantitative Conductive Mode Scanning Electron Microscopy, edited by Holt, D.B., Muir, M.D., Grant, P.R., and Boswarva, I.M. (Academic Press, London 1974) p. 213.Google Scholar
2. Reimer, L., Scanning Electron Microscopy: Physics of Image Formation and Microanalysis (Springer, Berlin 1998) p. 253.Google Scholar
3. Newbury, D.E., Joy, D.C., Echlin, P., Fiori, C. E., and Goldstein, J.I., Advanced Scanning Elecron Microscopy and X-Ray Microanalysis (Plenum Press, New York 1986) p. 61.Google Scholar
4. Leamy, H.J., J. Appl. Phys. 53 (6), R51 (1982).Google Scholar
5. Sparrow, T.G. and Valdre, U., Philosophical Magazine 36 (6), 1517 (1977).Google Scholar
6. Petroff, P.M., Logan, R.A., and Savage, A., Phys. Rev. Lett. 44 (4), 287 (1980).Google Scholar
7. Cabanel, C. and Laval, J.Y., J. Appl. Phys. 67 (3), 1425 (1990).Google Scholar
8. Cabanel, C., Maya, H., and Laval, J.Y., Phil. Mag. Lett. 79 (2), 55 (1999).Google Scholar
9. Donolato, C., Solid State Electronics 25, 1077 (1982).Google Scholar