Hostname: page-component-cd9895bd7-gbm5v Total loading time: 0 Render date: 2024-12-27T02:08:42.709Z Has data issue: false hasContentIssue false

Detection of Cadmium using Conjugated Polymer Modified Electrodes

Published online by Cambridge University Press:  25 October 2012

Timothy Ponrathnam
Affiliation:
Department of Plastics Engineering, University of Massachusetts Lowell, MA 01854, U.S.A.
Seth Robertson
Affiliation:
Department of Civil and Environmental Engineering, University of Massachusetts Lowell, MA 01854, U.S.A.
Junghwan Cho
Affiliation:
Department of Civil and Environmental Engineering, University of Massachusetts Lowell, MA 01854, U.S.A.
Pradeep Kurup
Affiliation:
Department of Civil and Environmental Engineering, University of Massachusetts Lowell, MA 01854, U.S.A.
Ramaswamy Nagarajan
Affiliation:
Department of Plastics Engineering, University of Massachusetts Lowell, MA 01854, U.S.A.
Get access

Abstract

The detection of heavy metals in subsurface strata currently requires tedious sampling procedures followed by laboratory analysis using techniques such as atomic absorption spectroscopy (AAS) or inductively couple plasma atomic emission spectroscopy (ICP-AES). These techniques are extremely accurate and capable of detecting very low concentrations of metal ions. The main drawback of these techniques is that they are time consuming, expensive to perform and not portable. A portable sensor capable of detecting metals ion in solution is highly desirable. Anodic Stripping Voltammetry (ASV) can be utilized as a reliable method for the trace detection of metal ions in water. In order to improve the sensitivity of the electrochemical sensor, conjugated polymer films can be coated on the surface of the glassy carbon working electrodes. Stable films of poly (3,4 ethylenedioxythiophene) [PEDOT] and polythiophene copolymer [PTCPTA] were electrochemically synthesized on the surface of a glassy carbon electrode. These polymer modified electrodes were utilized for the detection of cadmium in water. The sensors are capable of detecting trace concentrations of cadmium approaching the maximum contamination limits imposed by the Environment Protection Agency (EPA).

Keywords

Type
Articles
Copyright
Copyright © Materials Research Society 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

US E.P.A., in National Primary Drinking Water Regulations. Washington GPO: May, 2009. (EPA 816-F-09–004).Google Scholar
Pyle, S. M., Nocerino, J. M., Deming, S. N., Palasota, J. A., Palasota, J. M., Miller, E. L., Hillman, D. C., Kuharic, C. A., Cole, W. H., Fitzpatrick, P. M., Watson, M. A., Nichols, K. D., Environ. Sci. Technol. 30, 204213, (1996).CrossRefGoogle Scholar
Kounaves, S. P., in Handbook of Instrumental Techniques for Analytical Chemistry, edited by Settle, F.A. (Prentice Hall PTR, Upper Saddle River, NJ, 1997), p709.Google Scholar
Metelka, R., Vytřas, K., Bobrowski, A., J. Solid State Electrochem. 4, 348, (2000).CrossRefGoogle Scholar
Tamer, U., Ertas, N., Erguner, O., Gundogdu, Y., Electroanalysis, 20(16), 18051810 (2008).CrossRefGoogle Scholar
Manisankar, P., Vedhi, C., Selvanathan, G., Arumugam, P., Microchim. Acta., 163, 289295, (2008).CrossRefGoogle Scholar
Yang, G., Qu, X., Shen, M., Wang, C., Qu, Q., Hu, X., Microchim Acta, 160, 275281 (2008).CrossRefGoogle Scholar
Minnick, L. J., Kilpatrick, M., J. Phys. Chem., 43(2), 259274, (1939).CrossRefGoogle Scholar