Article contents
Degradation and Recovery of Boron Doped Strained Silicon Germanium Layers After 1-MeV Electron Irradiation
Published online by Cambridge University Press: 25 February 2011
Abstract
1007×100 μm2 n+− Si/p-Si1−x Gex diodes fabricated on conventional p-type Si substrates are irradiated at room temperature with 1-MeV electrons with fluences from 1.0×1014 to 1.0×1015 e/cm2 in a high voltage transmission electron microscope. The boron concentration and germanium fraction of the Si1−x Gex epitaxial layer used for the diodes in this study are 5×1017 cm−3 and x = 0.12, respectively. The degradation of diodes is investigated by means of current/voltage and capacitance/voltage measurements. The characteristics of the electrically active defects induced in the Si1−x Gex epitaxial layer by irradiation are also examined by using deep level transient spectroscopy and capacitance/temperature measurements. The degradation of the diode performance and the presence of deep levels are investigated as a function of electron fluence. In order to examine the recovery process, an isochronal thermal anneal is performed in the temperature range between 100 and 400°C.
- Type
- Research Article
- Information
- Copyright
- Copyright © Materials Research Society 1993
References
REFERENCES
- 2